Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV IndraDrive C Compact Converters
Bosch Rexroth HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV IndraDrive C Compact Converters

Bosch Rexroth HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV IndraDrive C Compact Converters Item NO.: 2942581

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV IndraDrive C Compact Converters
Item NO. 2942581
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-19

Bosch Rexroth HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV IndraDrive C Compact Converters
Bosch Rexroth · IndraDrive C HCS03

Bosch Rexroth HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV
IndraDrive C Compact Converters

01

Product Introduction

Bosch Rexroth HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV are high-current IndraDrive C HCS03 compact converters in the 400–500 V input class. Their rectifier, DC bus and inverter stages form one drive power section, with W0210 and W0280 identifying separate maximum-current frames.

The DC-bus path of HCS03.1E-W0210-A-05-NNBV carries 85 kW rated power with the assigned choke, while HCS03.1E-W0280-A-05-NNBV carries 100 kW. X3, L+/L− and X5 retain the same functional sequence, but the rated mains current rises from 146 A to 176 A and the protection row changes with it.

HCS03.1E-W0210-A-05-NNBV supports 4, 8, 12 and 16 kHz switching; HCS03.1E-W0280-A-05-NNBV is documented for 4 and 8 kHz. At 4 kHz their continuous outputs are 145 A and 165 A, so the frequency list and current row must be read together rather than inferred from the shared 350 mm housing group.

Official manual technical drawing 1 for HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBVOfficial manual technical drawing 2 for HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV
02

Specification Details

Attribute HCS03.1E-W0210-A-05-NNBV HCS03.1E-W0280-A-05-NNBV
01Brand Bosch Rexroth Bosch Rexroth
02Product type Compact converter Compact converter
03Series IndraDrive C HCS03 IndraDrive C HCS03
04Rated mains input 3 × AC 400…500 V 3 × AC 400…500 V
05Rated mains current 146 A 176 A
06Branch-circuit fuse 160 A 200 A
07Maximum output current 210 A 280 A
08Continuous output current at 4 kHz 145 A 165 A
09Rated DC-bus power with choke 85 kW 100 kW
10Switching frequencies 4 / 8 / 12 / 16 kHz 4 / 8 kHz
11Continuous power dissipation 2000 W 1900 W
12Control-voltage input 24 V ±20% 24 V ±20%
13Housing width 350 mm 350 mm
14External-resistor cable cross-section 50 mm² 50 mm²
03

DC-Bus Capacity and Motor-Output Flow

The large HCS03 frames route substantial mains power through a controlled charging stage before the inverter produces motor current.

01

The choke defines a rated bus condition

With the assigned choke, HCS03.1E-W0210-A-05-NNBV carries 85 kW and HCS03.1E-W0280-A-05-NNBV carries 100 kW of rated DC-bus power. These values describe the complete input/DC-bus arrangement, not the motor output alone.

02

Motor current leaves through X5

The inverters of HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV switch bus energy to the three phases at X5. L+/L− remain the upstream DC node and must not be identified as motor terminals.

03

Regenerated energy returns upstream

During deceleration, HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV receive energy back from the motor inverter into the DC bus. The braking branch limits bus rise by directing permitted energy to the resistor circuit.

04

Protection, Cabling and Thermal Scale

The two models share a housing width, yet their protection and operating-frequency limits remain separate.

Fuses follow the input row

HCS03.1E-W0210-A-05-NNBV uses the 146 A input and 160 A fuse row; HCS03.1E-W0280-A-05-NNBV uses 176 A and 200 A. Equal cabinet width does not make the branch protection equal.

Switching-frequency lists diverge

HCS03.1E-W0210-A-05-NNBV retains four documented switching frequencies, whereas HCS03.1E-W0280-A-05-NNBV is limited to 4 and 8 kHz. Current checks must use only the frequencies published for the actual W code.

Heat belongs to the operating frame

The cabinet must remove 2000 W for HCS03.1E-W0210-A-05-NNBV or 1900 W for HCS03.1E-W0280-A-05-NNBV at continuous operation. Each figure remains connected to its own current and frequency conditions.

05

Product Questions

Which switching frequencies can be configured on HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV?

When checking HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV, w0210 is documented for 4, 8, 12 and 16 kHz; W0280 is documented for 4 and 8 kHz.

What continuous output values apply at 4 kHz to HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV?

The published 4 kHz values are 145 A for W0210 and 165 A for W0280. Keep this requirement with HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV.

Which photographs are useful for distinguishing HCS03.1E-W0210-A-05-NNBV from HCS03.1E-W0280-A-05-NNBV?

HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV should be recorded with this result: use a readable type plate plus the mains, DC-bus and motor terminal areas; the common width alone does not identify the power frame.

How should the input protection for HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV be separated?

HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV: Keep the 160 A fuse with W0210 and the 200 A fuse with W0280, together with the corresponding conductor row.

Does the shared 350 mm width make HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV electrically interchangeable?

For HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV, no. Their input currents, fuses, DC-bus power, maximum current and allowed switching frequencies differ.

Where is an external braking resistor connected on HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV?

Use X9 and the documented external-resistor cable boundary; the connection acts on the DC bus, not directly on the motor phases. This condition belongs to HCS03.1E-W0210-A-05-NNBV / HCS03.1E-W0280-A-05-NNBV.

06

What We Deliver

Moore Automation warehouse and customer support

Moore Automation

https://www.mvme.cn/

Moore Automation supports sourcing for PLC, DCS, drive, HMI, RTU, industrial computer and related control components. The company reference material highlights stocked items, worldwide supplier coordination and assistance with obsolete or difficult-to-find part numbers.

For HCS03.1E-W0210-A-05-NNBV and HCS03.1E-W0280-A-05-NNBV, sourcing records preserve the complete suffix and model-specific terminal photographs instead of combining the two high-current frames.

Multi-brand component sourcingObsolete-part enquiriesGlobal supplier coordinationModel-specific evidence
07

Recommended Models

  • Siemens 6ES7214-1HG40-0XB0
  • ABB PM564-RP
  • Bently Nevada 330106-05-30-10-02-00
  • Allen-Bradley 1794-IA16
  • Emerson IC694MDL740
  • GE IC660BBD100
  • B&R X20CS1030
  • Bosch Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW
  • Vibro-Meter CE281
  • Motorola MVME2306
  • Siemens 6ES7215-1AG40-0XB0
  • ABB PM564-RP-AC
  • Bently Nevada 330106-05-30-10-02-05
  • Allen-Bradley 1794-AENT
  • Emerson IC694ALG223
  • GE IC660BBD101
  • B&R X20IF10E1-1
  • Bosch Rexroth DDS02.1-W050-D
  • Vibro-Meter CE620
  • Motorola MVME2307
  • Siemens 6ES7215-1BG40-0XB0
  • ABB PM572
  • Bently Nevada 330180-50-00
  • Allen-Bradley 1794-AENTR
  • Emerson IC200CPUE05
  • GE IC660BBD110
  • B&R X20IF2772
  • Bosch Rexroth DDS02.1-W150-D
  • Vibro-Meter CV210
  • Motorola MVME2308
  • Siemens 6ES7215-1HG40-0XB0
  • ABB PM582
  • Bently Nevada 330180-50-05
  • Allen-Bradley 1794-ACN15
  • Emerson IC200MDL650
  • GE IC660BBD120
  • B&R X20BM01
  • Bosch Rexroth DDS02.1-W200-D
  • Motorola MVME2604
  • Siemens 6ES7217-1AG40-0XB0
  • ABB PM573-ETH-XC
  • Bently Nevada 330180-51-00
  • Allen-Bradley 1794-ACNR15
  • Emerson IC200MDL740
  • GE IC660BBR100
  • B&R X20BM12
  • Bosch Rexroth DDS02.2-W050-BE12-01-FW
  • Motorola MVME2604-712
  • Siemens 6ES7217-1BG40-0XB0
  • ABB PM583-ETH-XC
  • Bently Nevada 330180-51-05
  • Allen-Bradley 1794-ASB
  • Emerson IC200ALG264
  • GE IC660BBR101
  • B&R X20BM15
  • Bosch Rexroth DDS02.2-W100-BE12-01-FW
  • Motorola MVME2604-761
  • Siemens 6ES7212-1AF40-0XB0
  • ABB PM591-ETH-XC
  • Bently Nevada 330180-90-00

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.