Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth HCS02.1E-W0070-A-03-NNNN IndraDrive C Compact Converter
Bosch Rexroth HCS02.1E-W0070-A-03-NNNN IndraDrive C Compact Converter

Bosch Rexroth HCS02.1E-W0070-A-03-NNNN IndraDrive C Compact Converter Item NO.: 2942576

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth HCS02.1E-W0070-A-03-NNNN IndraDrive C Compact Converter
Item NO. 2942576
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-19

Bosch Rexroth HCS02.1E-W0070-A-03-NNNN IndraDrive C Compact Converter
Bosch Rexroth · IndraDrive C HCS02

Bosch Rexroth HCS02.1E-W0070-A-03-NNNN
IndraDrive C Compact Converter

01

Product Information

Bosch Rexroth HCS02.1E-W0070-A-03-NNNN is an IndraDrive C HCS02 compact converter that combines a three-phase mains rectifier, DC-bus section, braking circuit and motor inverter in one forced-air-cooled power section. It converts the 200–500 V AC input into a controlled three-phase motor output and exposes the DC bus for the permitted common-bus arrangement.

Power in HCS02.1E-W0070-A-03-NNNN enters at X3, passes through charging-current limitation and the rectifier, and reaches the internal 0.68 mF DC bus before the inverter supplies the motor at X5. X6 keeps motor-temperature and holding-brake wiring separate from the power conductors, while X9 forms the connection boundary for an external braking resistor.

The NNNN design of HCS02.1E-W0070-A-03-NNNN receives its 24 V control supply externally rather than deriving that supply from the DC bus. The 105 mm-wide housing uses forced ventilation with 80 mm clear space above and below, linking the 300 W continuous dissipation figure to an unobstructed cabinet airflow path.

Official manual technical drawing 1 for HCS02.1E-W0070-A-03-NNNN
02

Product Specifications

Attribute HCS02.1E-W0070-A-03-NNNN
01Brand Bosch Rexroth
02Product type Compact converter
03Series IndraDrive C HCS02
04Rated mains input 3 × AC 200…500 V
05Rated input current 30 A
06Output voltage 3 × AC 0…530 V
07UL output current 28 A
08Maximum output current at 4 kHz 70 A
09Continuous output current at 4 kHz 28 A
10Control-voltage input 24 V ±20%
11DC-bus capacitance 0.68 mF
12Rated DC-bus power with choke 14 kW
13Integrated braking resistor 0.5 kW continuous / 25 kW peak
14Housing size 352 × 105 × 206 mm
15Mass 6.80 kg
03

Power Conversion and DC-Bus Roles

The W0070 power section separates input conversion, stored DC energy and controlled motor output while keeping all three stages inside one housing.

01

Controlled charging before conversion

When HCS02.1E-W0070-A-03-NNNN is energized, its charging-current limiter prevents the DC-bus capacitors from appearing as an uncontrolled discharged load. The rectifier then establishes the DC voltage used by both the inverter and braking circuit.

02

A DC bus shared by two functions

The 0.68 mF bus in HCS02.1E-W0070-A-03-NNNN supplies the motor inverter during motoring and receives returned energy during deceleration. L+ and L− expose this same electrical node for the documented DC-bus connection; they are not AC input terminals.

03

Frequency changes usable current

HCS02.1E-W0070-A-03-NNNN can switch at 4, 8, 12 or 16 kHz, but continuous current falls as switching losses rise. The active frequency must therefore remain attached to every current value used in the load calculation.

04

Connections, Braking and Cooling Boundaries

Terminal roles and airflow clearances define how the converter joins the cabinet without mixing control, motor and braking circuits.

Motor auxiliaries do not share X5

X5 on HCS02.1E-W0070-A-03-NNNN carries the three motor phases. Temperature monitoring and holding-brake conductors terminate at X6, keeping low-power auxiliary signals outside the main inverter-output path.

External braking remains a bus function

An external resistor connected at X9 acts on the DC bus of HCS02.1E-W0070-A-03-NNNN through the braking transistor. Its resistance and power data belong to that circuit and do not describe the integrated resistor inside the converter.

Heat leaves through a defined vertical path

Forced air enters and exits the HCS02.1E-W0070-A-03-NNNN frame through the specified top and bottom zones. The 80 mm clearances are part of the rated thermal condition, not spare mounting space.

05

Questions & Answers

What should be checked before using X9 on HCS02.1E-W0070-A-03-NNNN?

For HCS02.1E-W0070-A-03-NNNN, confirm the permitted resistance, cable boundary and configured external-resistor data before connecting the braking resistor; X9 must not be treated as a motor or DC-bus terminal.

How should HCS02.1E-W0070-A-03-NNNN be identified before wiring?

Match the complete type-plate string, including W0070, the -03 voltage class and final NNNN design; those positions determine the power frame, mains class and control-supply arrangement. This condition belongs to HCS02.1E-W0070-A-03-NNNN.

Which wiring belongs at X5 and X6 on HCS02.1E-W0070-A-03-NNNN?

When checking HCS02.1E-W0070-A-03-NNNN, x5 carries the three motor-power phases. X6 carries the motor-temperature and holding-brake circuits, so the two connectors serve different electrical roles.

Where does the external 24 V supply enter HCS02.1E-W0070-A-03-NNNN?

The NNNN version receives 24 V control power at its control-voltage input. This path is separate from X3, which carries the three-phase mains supply. Keep this requirement with HCS02.1E-W0070-A-03-NNNN.

What cabinet clearance preserves the rating of HCS02.1E-W0070-A-03-NNNN?

HCS02.1E-W0070-A-03-NNNN should be recorded with this result: keep 80 mm free above and below the converter and maintain the forced-air direction shown in the dimensional page.

Why can the 70 A code not be used as continuous current for HCS02.1E-W0070-A-03-NNNN?

HCS02.1E-W0070-A-03-NNNN: W0070 identifies the maximum-current class. At 4 kHz the documented continuous value is 28 A, and higher switching frequencies reduce it further.

06

Company Overview

Moore Automation warehouse and customer support

Moore Automation

https://www.mvme.cn/

Moore Automation supplies industrial automation and electronic components for PLC, DCS, HMI, drive and control-system enquiries. The company reference material emphasizes broad inventory coverage, international supply and support for both current and difficult-to-source components.

For an HCS02.1E-W0070-A-03-NNNN enquiry, the complete order code, type-plate image, quantity and destination are recorded together so the request stays connected to the exact power and control-supply design.

Industrial automation supplyGlobal enquiry coverageExact model recordingCurrent and legacy components
07

Suggested Products

  • Siemens 6ES7288-7ST40-0AA0
  • ABB IMMFP12
  • Bently Nevada 330103-00-05-10-02-00
  • Allen-Bradley 2707-M485P3
  • Emerson IC695ALG600
  • GE IC660BBA104
  • Triconex 3706A
  • B&R X20AI8321
  • Bosch Rexroth HMS01.1N-W0110-A-07-NNNN
  • Yokogawa S2SC70D-SA12010
  • Woodward 8577-1844
  • ProSoft PLX51-DNPS
  • Vibro-Meter 200-582-916-034
  • Motorola MVME2304-0113
  • Siemens 6ES7288-6EC01-0AA0
  • ABB SPC810ev
  • Bently Nevada 330104-00-06-10-02-00
  • Allen-Bradley 2707-L8P1
  • Emerson IC695ALG608
  • GE IC660BBA105
  • Triconex 3708E
  • B&R X20AO2622
  • Bosch Rexroth HMS01.1N-W0070-A-07-NNNN
  • Yokogawa A2FVX1-D02010
  • Woodward 9904-802
  • ProSoft PLX51-HART-4O
  • Vibro-Meter 200-582-993-022
  • Motorola MVME2304-0121
  • Siemens 6ES7211-1AE40-0XB0
  • ABB 07KT94
  • Bently Nevada 330104-01-05-50-02-00
  • Allen-Bradley 2707-L40P1
  • Emerson IC695ALG616
  • GE IC660BBA106
  • Triconex 3805E
  • B&R X20AO4632
  • Bosch Rexroth HMS01.1N-W0150-A-07-NNNN
  • Yokogawa AFV30D-A41252
  • Woodward D9904-113
  • ProSoft PLX82-MNET-61850
  • Vibro-Meter TQ412
  • Motorola MVME2304-0123
  • Siemens 6ES7211-1BE40-0XB0
  • ABB 07KT97
  • Bently Nevada 330105-02-12-05-02-00
  • Allen-Bradley 2707-V40P1
  • Emerson IC695ALG728
  • GE IC660BBD020
  • Triconex 3806E
  • B&R X20AT2222
  • Bosch Rexroth HMS01.1N-W0054-A-07-NNNN
  • Yokogawa A2FV50D-A412000
  • Woodward 8404-329
  • ProSoft RLX2-IHNF-W-A
  • Vibro-Meter EA402
  • Motorola MVME2304-0131
  • Siemens 6ES7212-1AE40-0XB0
  • ABB 07KT98
  • Bently Nevada 330105-02-12-05-02-05
  • Allen-Bradley 2707-V40P2N

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.