Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth / HCS03.1E-W0150-A-05-NNBV / IndraDrive C Compact Converter
Bosch Rexroth / HCS03.1E-W0150-A-05-NNBV / IndraDrive C Compact Converter

Bosch Rexroth / HCS03.1E-W0150-A-05-NNBV / IndraDrive C Compact Converter Item NO.: 2940479

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth / HCS03.1E-W0150-A-05-NNBV / IndraDrive C Compact Converter
Item NO. 2940479
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-18

Bosch Rexroth HCS03.1E-W0150-A-05-NNBV IndraDrive C Compact Converter

IndraDrive C high-current converter

150 A maximum current400–500 V mains classNNBV power design

Bosch Rexroth / HCS03.1E-W0150-A-05-NNBV / IndraDrive C Compact Converter

SeriesHCS03 IndraDrive C
Frame225 mm wide
CoolingForced ventilation
01

Product Introduction

HCS03.1E-W0150-A-05-NNBV is a Bosch Rexroth IndraDrive C HCS03 compact converter for operating one three-phase asynchronous or synchronous motor. Its power section accepts the -05 three-phase mains class, builds the DC bus and supplies an inverter whose current limit is identified by the W0150 code.

Within HCS03.1E-W0150-A-05-NNBV, NNBV identifies an integrated braking transistor and a 24 V control-voltage supply that can be fed from the DC bus and from an external source. The braking transistor switches an external resistor connected to the braking branch, while the DC-bus capacitors supply the motor inverter and the L+/L- connection.

The 225 mm-wide housing of HCS03.1E-W0150-A-05-NNBV uses forced ventilation and needs 80 mm above plus 100 mm below the device. At 4 kHz the inverter reaches 150 A maximum and 95 A continuous output current; at higher switching frequencies the available continuous current decreases with the documented thermal limits.

HCS03.1E-W0100/W0150 housing dimensions, including the W0150 225 mm frame width.
HCS03.1E-W0100/W0150 housing dimensions, including the W0150 225 mm frame width.
02

Technical Information

Attribute HCS03.1E-W0150-A-05-NNBV
Brand Bosch Rexroth
Product type Compact converter
Series IndraDrive C HCS03
Mains connection 3 × AC 400…500 V (+10% / -15%)
Nominal mains voltage 3 × AC 400 V
Mains frequency 50…60 Hz ±2 Hz
Mains input continuous current 106 A
Maximum output current at 4 kHz 150 A
Continuous output current at 4 kHz 95 A
Continuous output current at 8 kHz 66 A
Control-voltage input 24 V ±20%
DC-bus rated power with mains choke 56 kW
Mass 20.0 kg
Housing dimensions 490 × 225 × 262 mm (H × W × D)
03

What the NNBV power structure contains

NNBV changes two internal branches: the braking path and the source arrangement for the 24 V control voltage.

01

Mains and DC-bus formation

The rectifier of HCS03.1E-W0150-A-05-NNBV accepts the -05 three-phase input and charges the DC-bus capacitance through the charging-current-limitation stage. The resulting bus is the shared source for the inverter and internal control-voltage converter.

02

Integrated control-voltage source

The V position in HCS03.1E-W0150-A-05-NNBV denotes control-voltage power from the DC bus and from an external 24 V source. These two stated sources belong to the control-voltage path, not to the motor-output terminals.

03

Braking transistor branch

The B position in HCS03.1E-W0150-A-05-NNBV denotes the integrated braking transistor. It switches the external braking-resistor branch when the configured DC-bus threshold and braking function call for energy dissipation.

04

High-current operation inside the cabinet

Frame size, mains impedance, switching frequency and airflow all constrain the usable current path.

Mains topology fixes the rectifier reference

The mains side of HCS03.1E-W0150-A-05-NNBV is defined for the stated grounded three-phase systems and its assigned choke arrangement. The rectifier, choke and protective conductor form one input boundary; an unearthed or corner-grounded supply changes that boundary and is outside this configuration.

Switching choice changes thermal loading

Each increase in switching activity makes the semiconductors switch more often, so the continuous-current allowance of HCS03.1E-W0150-A-05-NNBV changes with the selected clock frequency. The maximum-current code identifies the power frame but does not replace the frequency-conditioned current table.

Airflow crosses the complete power frame

Forced air enters beneath HCS03.1E-W0150-A-05-NNBV, passes the heat-producing power section and leaves above the housing. Cable routing and neighboring devices must preserve this bottom-to-top path so the fan is not recirculating heated cabinet air.

05

Frequently Asked Questions

1. For HCS03.1E-W0150-A-05-NNBV, what does NNBV say about the internal hardware?

It identifies the integrated braking transistor and the control-voltage supply fed from the DC bus and from an external source on HCS03.1E-W0150-A-05-NNBV.

2. Can the -05 mains class be connected to an IT system on HCS03.1E-W0150-A-05-NNBV?

For HCS03.1E-W0150-A-05-NNBV, the stated supply is 3 × AC 400–500 V on TN-S, TN-C or TT mains; IT and corner-grounded-delta connections are not allowed for this class.

3. HCS03.1E-W0150-A-05-NNBV: Why does the continuous current change when switching frequency changes?

With HCS03.1E-W0150-A-05-NNBV, semiconductor and cooling losses increase with switching frequency, so the documented continuous output falls from 95 A at 4 kHz to lower values at 8, 12 and 16 kHz.

4. Where does braking energy leave the DC bus for HCS03.1E-W0150-A-05-NNBV?

The integrated braking transistor switches the external braking-resistor branch, allowing DC-bus energy to be dissipated in the connected resistor for HCS03.1E-W0150-A-05-NNBV.

5. Regarding HCS03.1E-W0150-A-05-NNBV, how much free space belongs to the forced-air path?

On HCS03.1E-W0150-A-05-NNBV, maintain 80 mm above and 100 mm below the 490 mm-high housing, with the mounting surface kept clear behind the device.

6. Which dimension distinguishes the W0150 frame in the drawing with HCS03.1E-W0150-A-05-NNBV?

In HCS03.1E-W0150-A-05-NNBV, the W0100/W0150 housing group is 262 mm deep, and the W0150 version uses the 225 mm frame width.

06

More About Moore Automation

Moore Automation company operations

Moore Automation

https://www.mvme.cn/

Moore Automation structures an HCS03 enquiry around the full NNBV designation. The customer record can include the mains-system type, the external braking-resistor data and the source used for the 24 V control circuit.

Keeping these three paths separate avoids reducing the request to a 150 A current label. The type plate and cabinet connection photographs remain attached to the same enquiry record.

Mains topology statedBraking branch documented24 V source arrangement capturedFrame and airflow evidence included
07

Selected Products

  • Emerson VE3005
  • GE IC670ALG620
  • Honeywell 8C-TCNTA1
  • Triconex 8107X
  • HIMA F8621A
  • B&R X20CP1684X
  • Bosch Rexroth HMS01.1N-W0036-A-07-NNNN
  • Yokogawa SAI533-H63/PRP
  • Woodward 5501-367
  • ProSoft PLX32-EIP-MBTCP-UA
  • Vibro-Meter IOC4
  • Motorola MVME147-012A
  • Siemens 6ES7288-1CR20-0AA0
  • ABB PM856AK01
  • Bently Nevada 330130-045-00-05
  • Allen-Bradley 1734-IE4C
  • Emerson SLS1508
  • GE IC670ALG621
  • Honeywell FC-SDI-1624
  • Triconex 8108X
  • HIMA H7015A
  • B&R X20CP0484
  • Bosch Rexroth HMS01.1N-W0210-A-07-NNNN
  • Yokogawa AAB841-S53/M4A00
  • Woodward 9905-969
  • ProSoft PLX82-EIP-61850
  • Vibro-Meter XMV16
  • Motorola MVME147-022
  • Siemens 6ES7288-1CR30-0AA0
  • ABB PM860AK01
  • Bently Nevada 330130-070-00-05
  • Allen-Bradley 1734-OE4C
  • Emerson KJ2221X1-BA1
  • GE IC670ALG630
  • Honeywell FC-SDOL-0424
  • Triconex 8109X
  • HIMA F7126
  • B&R X20CP0484-1
  • Bosch Rexroth HMS01.1N-W0300-A-07-NNNN
  • Yokogawa AAI543-S50/K4A00
  • Woodward 5466-332
  • ProSoft PLX51-PBM
  • Vibro-Meter XIO16T
  • Motorola MVME147-022A
  • Siemens 6ES7288-1CR40-0AA0
  • ABB PM864AK02
  • Bently Nevada 330130-080-01-05
  • Allen-Bradley 1734-IE2C
  • Emerson KJ2002X1-CA1
  • GE IC670MDL233
  • Honeywell CC-ZHR041
  • Triconex 8403X-1
  • HIMA F9203A
  • B&R X20CP0483
  • Bosch Rexroth HMS01.1N-W0350-A-07-NNNN
  • Yokogawa ADV169-PK0
  • Woodward Flex500
  • ProSoft PLX31-EIP-MBS4
  • Vibro-Meter VM600SYSMK2-001
  • Motorola MVME147-023
08

Contact & Enquiry

CompanyMoore Automation
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.