HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN are Bosch Rexroth IndraDrive M HMS01 single-axis inverters. Each unit receives 254–750 V DC from the shared IndraDrive DC bus and converts it into a controlled three-phase motor output; neither model contains the mains rectifier used by an HCS converter.
At 4 kHz, HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN provide different current boundaries: the W0110 unit has 110 A maximum and 68.5 A continuous output, while the W0070 unit has 70.7 A maximum and 42.4 A continuous output. Both use the same switching-frequency range, but their current and power-loss values follow their respective frame sizes.
For cabinet installation, HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN are both 440 mm high and 262 mm deep. The W0110 frame is 125 mm wide with 165 m³/h forced airflow, whereas the W0070 frame is 100 mm wide with 80 m³/h airflow; both need 80 mm above and 100 mm below for cooling and cable routing.
HMS01.1N-W0110 mounting geometry and minimum cable-clearance envelope.
02
Technical Specifications
Attribute
HMS01.1N-W0110-A-07-NNNN
HMS01.1N-W0070-A-07-NNNN
Brand
Bosch Rexroth
Bosch Rexroth
Product type
Single-axis inverter
Single-axis inverter
DC-bus input
254…750 V DC
254…750 V DC
Maximum output current at 4 kHz
110.0 A
70.7 A
Continuous output current at 4 kHz
68.5 A
42.4 A
Continuous output current at 8 kHz
43.5 A
24.1 A
Control-voltage input
24 V ±20%
24 V ±20%
Mass
11.06 kg
7.94 kg
Housing height
440 mm
440 mm
Housing width
125 mm
100 mm
Housing depth
262 mm
262 mm
Forced-air volume
165 m³/h
80 m³/h
Top / bottom clearance
80 / 100 mm
80 / 100 mm
03
How two inverters share one DC-bus architecture
Both devices start at L+ and L- and end at a three-phase motor output, but each power stage is sized for a different current class.
01
Common upstream source
HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN receive their power from an IndraDrive DC bus in the 254–750 V range. The upstream supply unit or feeding converter forms that bus; the HMS devices begin at the DC connection rather than at an AC mains input.
02
Independent motor stages
Each of HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN contains its own inverter bridge and motor connection. Commands and feedback control the corresponding axis, so the two current classes do not describe a combined two-axis output.
03
Shared control-voltage principle
Both HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN use a separate 24 V control input for their electronics. The control supply remains distinct from the high-voltage DC bus feeding the motor-output stage.
04
Frame size follows current and airflow demand
The larger current class changes width, fan volume, mass and loss figures while preserving height and depth.
W0110 heat-removal path
The W0110 member of HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN uses the wider frame to carry its larger power section, heat sink and forced-air path. Motor conductors and cooling air therefore belong to the W0110 envelope even though the DC-bus and control-supply roles match the W0070 device.
W0070 heat-removal path
The W0070 member of HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN performs the same DC-to-motor conversion in a narrower frame with its own fan requirement. Its smaller enclosure does not authorize use of the W0110 conductor, loss or ventilation data.
Clearance serves air and cable movement
Both HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN reserve space above and below for forced-air movement and cable exit. Those clear areas are functional parts of the installation envelope, while the different frame widths determine side-to-side cabinet occupation.
1. For HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN, can either inverter be connected directly to the AC mains?
No. Both are IndraDrive M inverters that receive 254–750 V DC from the system DC bus; the AC mains rectifier belongs upstream on HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN.
2. How should the 110 A and 70 A designations be compared on HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN?
For HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN, compare current at the same switching frequency: at 4 kHz the W0110 is 110.0 A maximum / 68.5 A continuous, while the W0070 is 70.7 A maximum / 42.4 A continuous.
3. HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN: Do the two devices occupy the same cabinet width?
With HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN, no. W0110 is 125 mm wide and W0070 is 100 mm wide, although both are 440 mm high and 262 mm deep.
4. Why are their fan-volume values different for HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN?
The W0110 power stage has the larger current and loss envelope and uses 165 m³/h, while W0070 uses 80 m³/h for HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN.
5. Regarding HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN, what clearance remains common to both frames?
On HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN, both require 80 mm above and 100 mm below for the defined forced-air and cable-routing space.
6. Does the separate 24 V input carry motor power with HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN?
In HMS01.1N-W0110-A-07-NNNN and HMS01.1N-W0070-A-07-NNNN, no. The 24 V input feeds control electronics; motor power is taken from the 254–750 V DC bus and converted by each inverter.
For a paired HMS enquiry, Moore Automation lists the W0110 and W0070 codes on separate rows. Each row can carry its type-plate photo, frame width and 4 kHz current values, preventing the larger current class from being attached to the smaller housing.
The upstream DC-bus source is recorded as system information rather than being assumed from either inverter code. This keeps the power-supply unit and the two axis inverters distinct.
One evidence row per modelFrame width paired with current classDC-bus source noted separatelyType plates kept in model order