Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN IndraDrive M Motor Inverters
Bosch Rexroth HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN IndraDrive M Motor Inverters

Bosch Rexroth HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN IndraDrive M Motor Inverters Item NO.: 2942586

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN IndraDrive M Motor Inverters
Item NO. 2942586
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-19

Bosch Rexroth HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN IndraDrive M Motor Inverters
Bosch Rexroth · IndraDrive M HMS01

Bosch Rexroth HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN
IndraDrive M Motor Inverters

01

Product Introduction

Bosch Rexroth HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN are large-frame IndraDrive M motor inverters. Each receives 254–750 V DC from the common drive bus and switches that energy into a three-phase motor output, with W0300 and W0350 identifying different maximum-current stages.

The power terminals of HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN keep L+/L− upstream of the inverter and X5 downstream toward the motor. Returned motor energy flows back to the common bus, so braking and regeneration are handled at system level rather than by treating either HMS01 as a standalone mains converter.

Continuous loss is documented as 1700 W for HMS01.1N-W0300-A-07-NNNN and 2750 W for HMS01.1N-W0350-A-07-NNNN. The W0350 dimensional arrangement includes the HAB01 fan unit; its fan hardware and airflow envelope are therefore part of the complete installation boundary.

Official manual technical drawing 1 for HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNNOfficial manual technical drawing 2 for HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN
02

Specification Details

Attribute HMS01.1N-W0300-A-07-NNNN HMS01.1N-W0350-A-07-NNNN
01Brand Bosch Rexroth Bosch Rexroth
02Product type Motor inverter Motor inverter
03Series IndraDrive M HMS01 IndraDrive M HMS01
04DC-bus input DC 254…750 V DC 254…750 V
05Output voltage 3 × AC 0…500 V 3 × AC 0…500 V
06Maximum-current class 300 A 350 A
07Control-voltage input 24 V ±20% 24 V ±20%
08Cooling Forced ventilation HAB01 external fan arrangement
09Continuous power dissipation 1700 W 2750 W
10Nominal ambient range 0…40 °C 0…40 °C
11Reduced-data ambient limit 55 °C 55 °C
12Installation drawing R911318790 p131 R911318790 p132
03

High-Power Inverter Energy Flow

Both models occupy the motor-side half of the IndraDrive M energy chain, between the shared DC bus and one controlled axis.

01

DC energy arrives from the supply unit

HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN receive the established bus voltage at L+/L−. Their type code does not describe a direct AC mains input because rectification occurs elsewhere in the system.

02

Semiconductors create the output waveform

The inverter stages of HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN switch DC energy to X5 under drive control. The W code identifies the maximum-current frame used for that conversion.

03

Deceleration reverses the energy direction

When a connected motor regenerates, HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN return energy through their inverter stages to the common DC bus, where the system supply or braking hardware handles it.

04

Mechanical Envelope and Auxiliary Fan Division

The W0350 frame adds a distinct fan assembly, while each model retains its own thermal load and mounting drawing.

Loss data belong to separate cabinets rows

HMS01.1N-W0300-A-07-NNNN contributes 1700 W of continuous loss and HMS01.1N-W0350-A-07-NNNN contributes 2750 W. These values are added to the cabinet heat balance independently.

HAB01 completes the W0350 airflow path

The dimensional figure for HMS01.1N-W0350-A-07-NNNN includes the HAB01 fan unit. Removing the fan from the installation envelope would omit the component that provides the documented cooling path.

Power and auxiliary wiring remain divided

HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN separate the high-current motor connection from temperature and brake wiring. The cable layout should follow those connector zones.

05

Product Questions

Why is HAB01 part of the HMS01.1N-W0350-A-07-NNNN installation record?

HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN: The W0350 dimensional arrangement includes that fan unit, so it forms part of the cooling and mounting envelope.

Which images prevent confusion between HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN?

For HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN, use separate type-plate, terminal and full-frame photographs, with the W0350 fan assembly visible in its installation image.

Where is motor power connected on HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN?

The controlled three-phase motor output uses X5; L+/L− remain the common DC-bus input. This condition belongs to HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN.

What is the upstream supply for HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN?

When checking HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN, both receive DC 254–750 V from the IndraDrive M bus at L+/L−; neither is a direct mains rectifier.

How should cabinet losses be entered for HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN?

Use separate continuous-loss entries of 1700 W and 2750 W rather than one family-level estimate. Keep this requirement with HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN.

What does W0300 versus W0350 identify in HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN?

HMS01.1N-W0300-A-07-NNNN / HMS01.1N-W0350-A-07-NNNN should be recorded with this result: the W position identifies different maximum-current power stages and therefore different thermal and mechanical boundaries.

06

Reasons Customers Rely on Us

Moore Automation warehouse and customer support

Moore Automation

https://www.mvme.cn/

Moore Automation coordinates sourcing, quotation, secure packing and international delivery through one assigned contact. The company reference material also emphasizes shipment tracking and regular status updates after an order enters the logistics stage.

For HMS01.1N-W0300-A-07-NNNN and HMS01.1N-W0350-A-07-NNNN, separate frame photographs preserve the W0350 HAB01 fan arrangement and prevent the two large inverter frames from being merged.

Assigned account contactSecure packing processInternational deliveryShipment tracking updates
07

Recommended Models

  • Bently Nevada 3500/32M
  • Allen-Bradley 1766-L32BWA
  • GE IC5005TBW0000
  • B&R X20SI4100
  • Bosch Rexroth TDM7.1-050-300-W1
  • Motorola MVME2700-1331
  • Siemens 6ES7231-5PD32-0XB0
  • ABB SM560-S-FD-4-XC
  • Bently Nevada 3500/33
  • Allen-Bradley 1766-L32BWAA
  • GE IC5008TAW0000
  • B&R X20SI8100
  • Bosch Rexroth TDM7.1-100-300-W1
  • Motorola MVME5100
  • Siemens 6ES7231-5QD32-0XB0
  • ABB BRC100
  • Bently Nevada 3500/40M
  • Allen-Bradley 1766-L32BXB
  • GE IC5008TBW0000
  • B&R X20SO4110
  • Bosch Rexroth TDA1.1-100-3-A00
  • Motorola MVME5100-0161
  • Siemens 6ES7232-4HB32-0XB0
  • ABB IMMFP11
  • Bently Nevada 3500/42M
  • Allen-Bradley 1766-L32BXBA
  • GE IC5002TAW1000
  • B&R X20SO4120
  • Bosch Rexroth HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW
  • Motorola MVME5100-0163
  • Siemens 6ES7232-4HD32-0XB0
  • ABB SPC810e
  • Bently Nevada 3500/44M
  • Allen-Bradley 1766-L32AWA
  • GE IC5005TAW1000
  • B&R X20SC2432
  • Bosch Rexroth HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW
  • Motorola MVME5110
  • Siemens 6ES7234-4HE32-0XB0
  • ABB SPC810ev2K02
  • Bently Nevada 3500/45
  • Allen-Bradley 1766-L32AWAA
  • GE IC5008TAW1000
  • B&R X20SL8000
  • Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW
  • Motorola MVME5110-2161
  • Siemens 6ES7241-1CH32-0XB0
  • ABB 07KT92
  • Bently Nevada 3500/46M
  • Allen-Bradley 1763-L16BWA
  • GE IC5002TAW4000
  • B&R X67DI1371
  • Bosch Rexroth HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW
  • Motorola MVME5110-2261
  • Siemens 6ES7241-1AH32-0XB0
  • ABB 07KT93
  • Bently Nevada 3500/50M
  • Allen-Bradley 1763-L16BBB
  • GE IC5005TAW4000
  • B&R X67DO1332

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.