Emerson A3210/022-000 AMS 3210 Shaft-Position Monitor

Emerson A3210/022-000 AMS 3210 Shaft-Position Monitor Item NO.: 2944302

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Emerson A3210/022-000 AMS 3210 Shaft-Position Monitor
Item NO. 2944302
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category EMERSON
Brand EMERSON
Creation Time 2026-11-23

Emerson A3210/022-000 AMS 3210 Shaft-Position Monitor

AMS position monitor · dual-channel axial displacement

Emerson A3210/022-000 AMS 3210 Shaft-Position Monitor

Shaft-position measurement and output routing

Product Introduction

Emerson A3210/022-000 is a dual-channel AMS 3210 shaft-position monitor with internal eddy-current converters and Lemo probe inputs. It measures shaft position or displacement on two channels and makes each result available locally, through isolated current outputs and through configurable relay contacts.

For each A3210/022-000 channel, the eddy-current probe gap becomes a position value within the range selected for the connected sensor. A 10 Hz low-pass characteristic removes faster motion from the position output, while the buffered 2–10 V connection retains the underlying sensor signal for measurement checks.

The A3210/022-000 wall enclosure receives 24 VDC and routes two sensor inputs, two current loops and five make-contact relays through separate connection points. Because the current output can operate in either direction, a replacement must copy the range, zero reference and output direction before external logic is reconnected.

Verified product data

Technical Information

Brand Emerson
Model A3210/022-000
Product Name AMS 3210 Shaft-Position Monitor
Channels 2
Converter Arrangement Internal eddy-current converters
Sensor Connections 2 Lemo sockets
Measurement Shaft position / displacement
Measurement Range Selectable to connected sensor
Low-Pass Filter 10 Hz
Buffered Outputs 2, 2 to 10 V ±2.5%
Current Outputs 2, 0/4 to 20 mA, galvanically isolated
Current Direction Selectable
Maximum Current-Loop Load 500 Ω
Relay Outputs 5 make contacts
Relay Rating 48 VDC, 1 A, 50 W maximum
Nominal Supply 24 VDC
Supply Range 18 to 31.2 VDC
Power Consumption 6 W maximum
Operating Temperature -20 to 65°C
Degree of Protection IP65
Mounting Wall mounted
Approximate Weight 1300 g
Probe gap to position value

Position Measurement Path

The monitor turns two probe-gap signals into independently ranged position values while preserving access to the raw sensor level.

Range association

The configured range follows the connected eddy-current sensor. Probe type and channel range must be treated as one setting pair.

10 Hz filtering

The low-pass characteristic keeps the current output focused on shaft position instead of faster vibration components that belong to another measurement function.

Buffered access

The 2–10 V buffered output allows the probe signal to be checked without replacing the processed current-loop value used by the control system.

Direction, zero and relay state

Output Configuration

Position becomes actionable only after zero reference, output direction and relay mapping agree with the machine coordinate system.

Output direction

The current loop can increase or decrease with shaft movement. The selected direction must match the receiving system rather than be inferred from terminal polarity.

Reference position

The channel zero establishes where displacement is measured from. A probe remount therefore requires both mechanical gap restoration and electrical reference verification.

Relay conditions

Five make contacts can represent configured position states. Existing terminal and logic assignments should be copied before A3210/022-000 is exchanged.

Installation and troubleshooting

Frequently Asked Questions

How can the output direction of A3210/022-000 be verified?+
Move the shaft or probe through a controlled, safe direction and observe both the A3210/022-000 display and current loop. Confirm the configured direction matches the receiving system before restoring relay action.
Why does A3210/022-000 reach an alarm immediately after probe installation?+
The A3210/022-000 mechanical gap or zero reference may not match the previous installation. Restore the documented probe position and sensor range before changing the alarm threshold.
What records are essential before replacing A3210/022-000?+
Save the two A3210/022-000 sensor types, ranges, zero references, current-output modes, directions and relay assignments. Photograph the Lemo inputs and terminal wiring.
Can A3210/022-000 use the buffered output as the control-system position value?+
The A3210/022-000 buffered output represents the sensor signal, while the isolated current loop carries the configured position value. Use the connection that matches the receiving system design.
What should be checked if one A3210/022-000 channel moves opposite to the other?+
Compare the A3210/022-000 channel output-direction settings, probe mounting directions and current-loop scaling. Do not swap relay wires to correct a measurement-direction error.
Which details identify A3210/022-000 for an enquiry?+
Provide A3210/022-000 in full, the two probe models, output modes, supply voltage, quantity and monitor-label photo. Note whether current direction and relay logic must be preserved.
Company information

Service Support

Moore Automation

https://www.mvme.cn/

Moore Automation maintains a clear handoff from technical enquiry to order documentation. Manufacturer, model, suffix and accessory scope remain readable at each stage, reducing confusion between products that share a series name.

Clear handoffReviewed data carries into the order.
Suffix visibilityVariant codes are not shortened.
Scope separationModules and accessories stay distinct.
Reference continuityThe original request remains traceable.
Direct contact

Contact & Enquiry

Moore Automationhttps://www.mvme.cn/
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.