The fieldbus carries control words and status
DKC03.1-040-7-FW and DKC03.3-040-7-FW exchange command and status data through their PROFIBUS-DP interface. This network path is distinct from the motor power and feedback connectors.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bosch Rexroth DKC03.1-040-7-FW / DKC03.3-040-7-FW ECODRIVE PROFIBUS-DP Drive Controllers |
| Item NO. | 2942593 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BOSCH |
| Brand | BOSCH |
| Creation Time | 2026-11-19 |
Bosch Rexroth DKC03.1-040-7-FW and DKC03.3-040-7-FW are ECODRIVE drive controllers whose DKC03 identity provides the PROFIBUS-DP command interface. Both use the 040-7 power stage to convert a 380–480 V three-phase supply into a 500–800 V DC bus and controlled motor output.
At 4 kHz, DKC03.1-040-7-FW and DKC03.3-040-7-FW provide 16 A continuously from a 40 A peak frame; at 8 kHz the continuous value is 12.5 A. The braking circuit acts on the same DC bus, with a 0.15 kW continuous and 10 kW peak internal-resistor rating.
DKC03.1-040-7-FW and DKC03.3-040-7-FW share the 360 × 70 × 210 mm power-frame envelope, but `.1` and `.3` identify different controller generations. PROFIBUS connectors, firmware type plate, motor feedback and high-voltage terminals must therefore be checked as separate parts of the complete identity.
| Attribute | DKC03.1-040-7-FW | DKC03.3-040-7-FW |
|---|---|---|
| 01Brand | Bosch Rexroth | Bosch Rexroth |
| 02Product type | ECODRIVE controller | ECODRIVE controller |
| 03Command interface | PROFIBUS-DP | PROFIBUS-DP |
| 04Controller generation | .1 | .3 |
| 05Power input | 3 × AC 380…480 V | 3 × AC 380…480 V |
| 06Peak output current | 40 A | 40 A |
| 07Continuous current at 4 kHz | 16 A | 16 A |
| 08Continuous current at 8 kHz | 12.5 A | 12.5 A |
| 09DC-bus voltage | 500…800 V | 500…800 V |
| 10Control-voltage input | 19.2…28.8 V | 19.2…28.8 V |
| 11Continuous power loss | 180 W | 180 W |
| 12Braking resistor | 0.15 kW continuous / 10 kW peak | 0.15 kW continuous / 10 kW peak |
| 13Dimensions | 360 × 70 × 210 mm | 360 × 70 × 210 mm |
| 14Protection | IP20 | IP20 |
The DKC03 control path links network commands to the internal drive processor while motor feedback closes the axis loop locally.
DKC03.1-040-7-FW and DKC03.3-040-7-FW exchange command and status data through their PROFIBUS-DP interface. This network path is distinct from the motor power and feedback connectors.
The separately identified firmware in DKC03.1-040-7-FW and DKC03.3-040-7-FW processes the fieldbus commands and applies the configured drive functions. Firmware identity remains tied to the `.1` or `.3` hardware generation.
Feedback enters DKC03.1-040-7-FW or DKC03.3-040-7-FW independently of PROFIBUS. The controller combines actual motor data with the network command before switching the power stage.
The controller front divides high-voltage energy, motor sensing and network communication into separate connector groups.
DKC03.1-040-7-FW and DKC03.3-040-7-FW rectify 380–480 V AC and establish a 500–800 V DC bus. That bus supplies the inverter and the internal braking circuit.
The X9 path of DKC03.1-040-7-FW and DKC03.3-040-7-FW is reserved for the documented DC-bus extension arrangement. It must remain physically and functionally separate from PROFIBUS wiring.
Although the peak class is 40 A, DKC03.1-040-7-FW and DKC03.3-040-7-FW dissipate heat according to the continuous current and switching frequency. The 180 W continuous-loss value belongs in the cabinet calculation.
Use the DKC03 fieldbus connector zone and keep it separated from mains, motor and X9 DC-bus conductors. Keep this requirement with DKC03.1-040-7-FW / DKC03.3-040-7-FW.
DKC03.1-040-7-FW / DKC03.3-040-7-FW should be recorded with this result: use the complete type plate, firmware label and front connector view so the generation digit and PROFIBUS interface are both verifiable.
DKC03.1-040-7-FW / DKC03.3-040-7-FW: No. The documented continuous limits are 16 A at 4 kHz and 12.5 A at 8 kHz; 40 A is the peak class.
For DKC03.1-040-7-FW / DKC03.3-040-7-FW, x9 provides the documented 500–800 V DC-bus link; it is not a PROFIBUS or motor-feedback connection.
Both are DKC03 PROFIBUS-DP controllers; the `.1` or `.3` generation must also remain in the complete code. This condition belongs to DKC03.1-040-7-FW / DKC03.3-040-7-FW.
When checking DKC03.1-040-7-FW / DKC03.3-040-7-FW, the `FW` suffix means firmware is ordered separately, and its type must match the controller generation and configured drive function.
Moore Automation supplies across PLC, DCS, RTU, IPC, HMI, drive, sensor and industrial-control accessory categories. The company reference material presents this range together with worldwide delivery and assistance locating current or obsolete components.
DKC03.1-040-7-FW and DKC03.3-040-7-FW remain separate Bosch Rexroth entries so the PROFIBUS identity, generation digit and firmware label are preserved.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found