Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>EMERSON>Emerson A3110/022-000 AMS 3110 Shaft-Vibration Monitor
Emerson A3110/022-000 AMS 3110 Shaft-Vibration Monitor

Emerson A3110/022-000 AMS 3110 Shaft-Vibration Monitor Item NO.: 2944301

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Emerson A3110/022-000 AMS 3110 Shaft-Vibration Monitor
Item NO. 2944301
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category EMERSON
Brand EMERSON
Creation Time 2026-11-23

Emerson A3110/022-000 AMS 3110 Shaft-Vibration Monitor

AMS protection monitor · dual-channel shaft vibration

Emerson A3110/022-000 AMS 3110 Shaft-Vibration Monitor

Dual-channel relative shaft-vibration processing

Product Overview

Emerson A3110/022-000 is a dual-channel AMS 3110 shaft-vibration monitor with internal eddy-current converters. It accepts two compatible probe signals through Lemo sockets, processes relative shaft vibration and presents the measured condition through local display, analog outputs and relay contacts.

Inside A3110/022-000, each channel converts probe gap variation into a vibration value, then applies the configured high-pass and low-pass limits before comparing the result with alarm settings. Buffered voltage outputs preserve access to the dynamic sensor signal, while isolated current outputs carry the processed measurement to another control or recording system.

The wall-mounted A3110/022-000 enclosure separates sensor entry, power entry, analog outputs and relay wiring across its connection area. Five make-contact relays translate configured monitor states into external signals, so channel configuration and terminal assignments must be documented before a replacement is wired.

Verified product data

Product Data

Brand Emerson
Model A3110/022-000
Product Name AMS 3110 Shaft-Vibration Monitor
Channels 2
Converter Arrangement Internal eddy-current converters
Sensor Connections 2 Lemo sockets
Measurement Relative shaft vibration
PR6422 Range 0 to 250 µm
PR6423 Range 0 to 500 µm
PR6424 / PR6425 Range 0 to 1000 µm
High-Pass Filter 1, 5 or 10 Hz
Low-Pass Filter 50 to 1500 Hz
Buffered Outputs 2, 2 to 10 V ±2.5%
Current Outputs 2, 0/4 to 20 mA, galvanically isolated
Maximum Current-Loop Load 500 Ω
Relay Outputs 5 make contacts
Relay Rating 48 VDC, 1 A, 50 W maximum
Nominal Supply 24 VDC
Supply Range 18 to 31.2 VDC
Power Consumption 6 W maximum
Operating Temperature -20 to 65°C
Degree of Protection IP65
Mounting Wall mounted
Approximate Weight 1300 g
Probe signal to alarm value

Channel Processing

Each input channel converts probe motion, shapes the frequency band and produces both a measured value and configurable monitor state.

Internal conversion

The /022-000 version contains both eddy-current converters, so the probe cables terminate directly at the monitor instead of at separately ordered converters.

Frequency shaping

Selectable high-pass and low-pass settings define which shaft-motion components enter the vibration value. The filter limits must follow the machine measurement requirement.

Output separation

Buffered voltage retains dynamic sensor information, while the isolated current loop represents the processed channel value for a remote system.

Alarm states and external wiring

Relay and Interface Behavior

Five relay contacts and two analog channels allow the monitor to report measured vibration without combining every condition into one output.

Channel states

The two measurement channels are configured independently, so a sensor problem on one channel can be distinguished from a vibration condition on the other.

Relay mapping

Relay contacts act only as configured; terminal labels and logic must be captured before disconnecting an existing A3110/022-000.

Wall enclosure

The IP65 housing brings probes, supply and outputs into one monitor. Cable glands and strain relief preserve the boundary between field wiring and internal electronics.

Installation and troubleshooting

Questions About This Product

Why does A3110/022-000 show no reading on one channel after replacement?+
Check the A3110/022-000 Lemo connection, probe type and channel configuration before changing alarm values. The /022-000 version expects the sensor signal at its internal converter input.
Which settings should be recorded before removing A3110/022-000?+
Record both A3110/022-000 probe selections, ranges, high-pass and low-pass settings, alarm levels, relay assignments and current-output directions. Photograph terminal wiring before disconnection.
What can cause an A3110/022-000 current output to disagree with the display?+
Verify whether A3110/022-000 is configured for 0–20 mA or 4–20 mA and confirm the receiving load is within 500 Ω. Then compare the configured measurement range with the displayed channel range.
How should A3110/022-000 relay wiring be checked?+
Identify which of the five A3110/022-000 make contacts is assigned to each condition and confirm the external circuit stays within the contact rating. Do not infer relay purpose from wire color alone.
Why can A3110/022-000 report vibration after a probe change?+
A different probe gap, range or filter setting changes what A3110/022-000 processes. Restore the mechanical probe position and verified channel configuration before judging the alarm condition.
What should be supplied with an A3110/022-000 enquiry?+
Include the complete A3110/022-000 code, both probe models, quantity, power supply, output mode and enclosure-label photo. State whether the replacement must retain existing relay logic.
Company information

Our Services

Moore Automation

https://www.mvme.cn/

Moore Automation organizes multi-brand enquiries around traceable product identities. Each requested monitor, sensor or I/O module is recorded independently, while photos and available documentation can be associated with that exact item before dispatch.

Independent linesEach requested item has its own record.
Photo linkageLabels can be matched to the line item.
Document controlFiles follow the confirmed model.
Packing checkDispatch uses the reviewed model list.
Direct contact

Contact Information

Moore Automationhttps://www.mvme.cn/
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.