Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW / HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW IndraDrive Cs Compact Converters
Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW / HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW IndraDrive Cs Compact Converters

Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW / HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW IndraDrive Cs Compact Converters Item NO.: 2944597

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW / HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW IndraDrive Cs Compact Converters
Item NO. 2944597
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-24

Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW / HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW IndraDrive Cs Compact Converters

Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW / HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW IndraDrive Cs Compact Converters

Product facts

Product Information

HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW are IndraDrive Cs compact converters with integrated power and control sections. Both use the 03 mains class for three-phase 200–500 V input and provide a variable-frequency three-phase motor output through the compact HCS01 connection architecture.

The W0018 and W0028 fields separate HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW from HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW. Their documented family output-current boundaries are 7.6 A and 11.5 A, while their B/ET and E/S3 control-section options and NN versus L3 safety fields remain distinct.

HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW share the 70 mm housing group, 268 mm height and 196 mm depth. The connection set separates mains, motor, braking, encoder, communication and 24 V control circuits into labeled terminals.

Exact model data

Technical Data

Specification HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW
Brand Bosch Rexroth Bosch Rexroth
Product family IndraDrive Cs HCS01.1E IndraDrive Cs HCS01.1E
Product type Compact converter Compact converter
Power-section field W0018 W0028
Mains class 3 × AC 200–500 V 3 × AC 200–500 V
Rated input current 5.0 A 10.0 A
Output current 7.6 A 11.5 A
Output frequency range 0–1600 Hz 0–1600 Hz
Control voltage 24 V DC ±20% 24 V DC ±20%
Control-section block B / ET E / S3
Encoder interface EC EC
Safety-option field NN L3
Dimensions W × H × D 70 × 268 × 196 mm 70 × 268 × 196 mm
Mass 2.10 kg 2.10 kg
Continuous-current dissipation 80 W 120 W
System function

Rectifier-to-Motor Energy Flow

The compact converter carries energy from the three-phase mains through an internal DC link to the controlled motor output.

Path 01

Input stage

The 03 mains-class input feeds the converter power stage through the assigned protection and power terminals.

Path 02

DC-link boundary

Rectified energy is stored and controlled internally before it reaches the inverter stage; braking connections remain a separate branch.

Path 03

Motor output

The inverter produces a variable-frequency three-phase output within the W0018 or W0028 current boundary.

System function

Ethernet, Encoder and Safety Connections

Low-voltage interfaces occupy different terminal groups from the mains and motor conductors.

Path 01

Control communication

B/ET and E/S3 define different control-section records and network behavior within the HCS01 family.

Path 02

Encoder input

EC connects the motor-feedback path used for commutation, speed regulation and position information.

Path 03

Safety circuit

NN and L3 identify different safety-option positions; the exact field must remain tied to the installed external circuit.

Practical checks

Product Questions

01Which cable, encoder and connector checks address an encoder fault on HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW?

For HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW, verify the EC feedback cable, motor encoder identity and connector seating for the exact model.

02How should the NN and L3 safety options of HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW stay aligned with their external circuits?

For a site record covering HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW, retain NN or L3 with the complete model and match the external circuit to that installed safety option.

03Because the housings share a width, which record distinguishes the W0018 and W0028 versions of HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW?

On HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW, use the full W0018 or W0028 code and type plate rather than cabinet width alone.

04When HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW is installed in a dense cabinet row, which heat and spacing differences matter?

With HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW, inspect vertical airflow, spacing and the different 80 W versus 120 W dissipation levels.

05If mains is present but HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW gives no control response, what should be checked before the motor circuit?

For commissioning records for HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW, check 24 V control power, the exact control-section interface and the communication state before the motor circuit.

06Which power and low-voltage connection groups must remain separated when HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW is installed?

For a site record covering HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW and HCS01.1E-W0028-A-03-E-S3-EC-NN-L3-NN-FW, route mains and motor conductors apart from 24 V control, communication, EC feedback and safety wiring at their labeled terminal groups.

Traceable product and packing records

Reasons to Choose Us

Moore Automation

https://www.mvme.cn

Moore Automation can retain complete product identity, requested documentation and packing references throughout an industrial automation enquiry.

For the HCS01 pair, the different power, communication and safety-option fields remain visible in quotation and shipment records instead of being reduced to a shared family name.

Traceable identityFull type code retained
Record alignmentDocuments linked to the right option set
Packing controlLabels kept visible for receiving
Shipment referenceTracking attached to the correct line

Sales Enquiries

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.