Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth TDA1.1-100-3-A00 Modular Main-Spindle Controller
Bosch Rexroth TDA1.1-100-3-A00 Modular Main-Spindle Controller

Bosch Rexroth TDA1.1-100-3-A00 Modular Main-Spindle Controller Item NO.: 2944595

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth TDA1.1-100-3-A00 Modular Main-Spindle Controller
Item NO. 2944595
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-24

Bosch Rexroth TDA1.1-100-3-A00 Modular Main-Spindle Controller

Bosch Rexroth TDA1.1-100-3-A00 Modular Main-Spindle Controller

Product facts

Product Overview

TDA1.1-100-3-A00 is a modular main-spindle controller for controlled 2AD asynchronous motors and 1MB frameless spindle motors. The controller operates from a 300 V DC link, carries a 100 A current rating and provides 70 A continuous effective current for spindle power and C-axis operation.

The A00 interface code on TDA1.1-100-3-A00 identifies an analog ±10 V speed-command input without the optional additional encoder input or additional interface. Standard control inputs, signal outputs, motor feedback and the ready contact remain part of the controller connection structure.

TDA1.1-100-3-A00 uses a plug-in AS programming module to hold motor matching, operating software and application parameters. Its high-resolution feedback processing supports low-speed C-axis control, while the modular busbars connect the controller to the common 300 V DC link and control-voltage bus.

Exact model data

Technical Specifications

Specification TDA1.1-100-3-A00
Brand Bosch Rexroth
Product family TDA 1.1
Product type Modular main-spindle controller
Current rating 100 A
Continuous effective current 70 A
DC-link rated voltage 300 V DC
Command interface Analog ±10 V
Additional encoder input Not included in A00
Additional interface Not included in A00
Cooling principle Air inside control cabinet
Control-voltage load 1.4 A at +24 V
±15 V test-voltage load 160 mA
Controller mass 10.5 kg
Protection IP10
Operating temperature +5 to +45 °C at nominal ratings
System function

Spindle Command Processing

The controller converts an NC command into parameterized speed, torque and position behavior inside the spindle drive.

Path 01

Analog command

The A interface receives a ±10 V speed command through X4 and keeps that path separate from the standard X2 control I/O.

Path 02

AS programming module

Motor-specific and application-specific parameters are stored in the removable programming module used by the digital controller.

Path 03

Power output

The 300 V link feeds the A1/A2/A3 motor terminals through a current-regulated output stage sized for the 100 A frame.

System function

Feedback and Positioning Chain

High-resolution feedback lets the same spindle power stage operate across speed control, positioning and C-axis modes.

Path 01

Motor feedback

X3 receives the high-resolution motor feedback signal used by the internal speed and position loops.

Path 02

C-axis positioning

Rotor position processing supports low-speed positioning and interpolation when the spindle is used as a servo axis.

Path 03

Standard signal path

X2 carries control inputs and signal outputs, while ready status and motor thermistor circuits retain their own terminals.

Practical checks

Frequently Asked Questions

01Before the NC is connected, which A00 interface boundaries must be confirmed on TDA1.1-100-3-A00?

With TDA1.1-100-3-A00, verify the analog X4 command path and do not assume an optional X5 encoder input or X6 additional interface.

02If TDA1.1-100-3-A00 is ready but does not follow the speed command, which conditions should be separated during diagnosis?

On TDA1.1-100-3-A00, check the ±10 V reference, X2 enable inputs, ready chain and stored parameters as separate conditions.

03Which parts of the 300 V modular bus should be checked around TDA1.1-100-3-A00?

When documenting TDA1.1-100-3-A00, inspect the supply module, busbars, adjacent controllers and control-voltage link with the DC bus safely discharged.

04What nameplate evidence confirms the motor and programming-module pairing for TDA1.1-100-3-A00?

To keep TDA1.1-100-3-A00 unambiguous, match the motor type, feedback identity and AS programming-module code with the controller plate.

05How can the low-speed C-axis behavior of TDA1.1-100-3-A00 be preserved in the application record?

For service work on TDA1.1-100-3-A00, retain the high-resolution feedback and application parameters that define low-speed position control.

06What operating information does the AS programming module provide to TDA1.1-100-3-A00?

For a site record covering TDA1.1-100-3-A00, use the AS module to retain the motor-specific and application-specific parameters that shape speed, torque and positioning behavior.

Multi-brand automation sourcing

Advantageous Brands

Moore Automation

https://www.mvme.cn

Moore Automation handles enquiries across established automation brands, including legacy drive and control families used in modular machine systems.

For the TDA controller, the complete model, programming-module identity and requested documents can be kept together while quotation, packing and shipment information are prepared.

Drive familiesBosch Rexroth and other motion brands
Control systemsPLC, DCS and industrial control parts
Exact recordsModel and module codes retained
Commercial follow-upQuotation through shipment tracking

Contact Information

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.