HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW are Bosch Rexroth IndraDrive Cs HCS01 compact single-axis converters in the -03 three-phase 200–500 V class. Both combine a mains rectifier, DC link, motor inverter and Basic control section with ET network and EC encoder interfaces, but the W0028 and W0054 power stages have different current and thermal capacities.
At the power terminals, HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW accept the same voltage range and expose X77 for the DC bus. W0028 is rated for 10.0 A input and 11.5 A output, while W0054 is rated for 28.0 A input and 21.0 A output; the larger unit also changes branch-circuit protection, conductor size and continuous heat loss.
The W0028 member of HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW is 70 mm wide and 2.10 kg, whereas the W0054 member is 130 mm wide and 4.60 kg. Both are 268 mm high and 196 mm deep, use 24 V control power, and share the ET X22/X23, EC X4 and Bb X47 signal organization.
HCS01.1E-W0054 standard-mounting dimensions with the wider 130 mm power frame.
02
Technical Information
Attribute
HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW
HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW
Brand
Bosch Rexroth
Bosch Rexroth
Product type
Compact single-axis converter
Compact single-axis converter
Rated power input
3 × AC 200…500 V
3 × AC 200…500 V
Rated input current
10.0 A
28.0 A
Branch-circuit protection fuse
15 A
30 A
Output voltage
3 × AC 0…500 V
3 × AC 0…500 V
Output current
11.5 A
21.0 A
Control-voltage input
24 V ±20%
24 V ±20%
Power dissipation at continuous current
120 W
400 W
Mass
2.10 kg
4.60 kg
Housing height
268 mm
268 mm
Housing width
70 mm
130 mm
Housing depth
196 mm
196 mm
DC-bus connection X77
Available
Available
03
Shared signal paths, unequal power stages
The control-section code remains the same while conductor current, heat loss and frame width increase with the power class.
01
Common ET and EC routing
Both members of HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW use X22/X23 for ET network traffic and X4 for EC motor-encoder feedback. The Basic control section processes the same kinds of command and feedback data.
02
W0028 power-stage boundary
The W0028 member of HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW processes the common command and encoder paths through its own current sensing, protection and motor-output stage. Its conductor and cooling data remain tied to the W0028 type plate even though the option suffix matches W0054.
03
W0054 power-stage boundary
The W0054 member of HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW keeps the same control architecture but expands the power, terminal and heat-removal envelope. The larger frame changes the cabinet and wiring boundary without changing the meaning of ET, EC or L3.
04
Cabling, heat and mounting scale together
The larger frame changes more than the current number: protection, wire size, heat removal and side-to-side cabinet occupation all move with it.
Branch protection belongs to each input row
The upstream branch protection for each member of HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW is coordinated with that model’s rated input and conductor table. A shared voltage class does not make the W0028 and W0054 protection entries interchangeable.
DC-bus and motor terminations
Both members of HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW provide X77 for L+/L-, X3 for mains and X5 for motor output. The same connector roles do not imply the same conductor cross-section or terminal loading.
Mounting drawing belongs to the power frame
The W0054 drawing beside HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW shows the boring position and front-face envelope for the wider device. W0028 requires its own frame drawing; a common height and depth do not make the side-to-side mounting coordinates identical.
1. For HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW, do the two models share the same input-voltage class?
Yes. Both use the -03 three-phase 200–500 V class and both provide the X77 DC-bus connection on HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW.
2. What current values distinguish the power stages on HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW?
For HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW, w0028 is 10.0 A input / 11.5 A output, while W0054 is 28.0 A input / 21.0 A output.
3. HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW: Why is the W0054 cabinet footprint larger?
With HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW, its 130 mm frame carries the higher-current power stage and 400 W continuous-current dissipation, compared with the 70 mm W0028 frame.
4. Can the same branch fuse entry be used for both for HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW?
No. The table lists 15 A for W0028 and 30 A for W0054, together with their model-specific input wiring data for HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW.
5. Regarding HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW, which communication and feedback connectors are common?
On HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW, both use ET at X22/X23 and EC encoder feedback at X4, with Bb ready status at X47.
6. How should X77 be described in the enquiry with HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW?
In HCS01.1E-W0028-A-03-B-ET-EC-NN-L3-NN-FW and HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW, identify X77 as the L+/L- DC-bus connection present on both -03 models; do not describe it as the AC mains or motor output.
Moore Automation keeps the W0028 and W0054 evidence sets separate even though the remaining option string is identical. Rated input, rated output, branch protection, width, mass and heat loss are recorded on the corresponding model row.
Connector photographs can confirm the shared ET, EC and X77 arrangement, while the type plates remain the source for deciding which current frame is present.
Current data stored per modelFrame width checked against plateFuse entry kept model-specificShared connectors documented once per row
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found