Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth KDA3.3-100-3-A00-W1 / KDA3.3-150-3-A00-W1 DIAX01 Main-Spindle Drive Controllers
Bosch Rexroth KDA3.3-100-3-A00-W1 / KDA3.3-150-3-A00-W1 DIAX01 Main-Spindle Drive Controllers

Bosch Rexroth KDA3.3-100-3-A00-W1 / KDA3.3-150-3-A00-W1 DIAX01 Main-Spindle Drive Controllers Item NO.: 2944592

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth KDA3.3-100-3-A00-W1 / KDA3.3-150-3-A00-W1 DIAX01 Main-Spindle Drive Controllers
Item NO. 2944592
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-24

Bosch Rexroth KDA3.3-100-3-A00-W1 / KDA3.3-150-3-A00-W1 DIAX01 Main-Spindle Drive Controllers

Bosch Rexroth KDA3.3-100-3-A00-W1 / KDA3.3-150-3-A00-W1 DIAX01 Main-Spindle Drive Controllers

Product facts

Product Description

KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1 are modular main-spindle drive controllers for controlled 2AD asynchronous motors and 1MB frameless spindle motors. Both use a 300 V DC bus and provide the current control, feedback processing and application functions required by a CNC spindle drive.

The rated-current field distinguishes KDA3.3-100-3-A00-W1 at 100 A from KDA3.3-150-3-A00-W1 at 150 A. Their documented continuous-current values are 70 A and 90 A respectively, while the common A00 interface block identifies the same analog-command and standard additional-interface arrangement.

The W1 ending on KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1 identifies forced cooling by the heatsink blower with a 220 V, 50–60 Hz blower supply. Internal heat enters the cabinet air, while the external heatsink and blower carry most power-stage heat outside the enclosure.

Exact model data

Product Specifications

Specification KDA3.3-100-3-A00-W1 KDA3.3-150-3-A00-W1
Brand Bosch Rexroth Bosch Rexroth
Product family KDA 3.3 KDA 3.3
Product type Main-spindle drive controller Main-spindle drive controller
Rated current 100 A 150 A
Continuous current 70 A 90 A
DC-bus rated voltage 300 V DC 300 V DC
Command interface Analog speed command Analog speed command
Additional encoder input None in A00 None in A00
Additional interface Standard / none in A00 Standard / none in A00
Cooling Forced, heatsink blower Forced, heatsink blower
Blower supply 220 V AC, 50–60 Hz 220 V AC, 50–60 Hz
Control-voltage current 1.4 A 1.6 A
±15 V test-voltage load 160 mA 160 mA
Controller mass 17.1 kg 17.4 kg
Protection IP10 IP10
System function

Main-Spindle Control Loop

The KDA controller links the CNC command, digital control loop, motor feedback and spindle power stage in one modular drive.

Path 01

Command conversion

The analog command enters the controller and is combined with parameters stored in the associated programming module.

Path 02

Rotor feedback

High-resolution motor feedback closes the speed and position loop across the controlled 2AD or 1MB spindle motor.

Path 03

Power modulation

The 300 V DC bus feeds a current-regulated output stage sized to the 100 A or 150 A controller frame.

System function

Forced-Air Heat Path

W1 cooling separates the internal electronics environment from the external heatsink airflow.

Path 01

Internal cabinet air

Control electronics release a smaller share of heat inside the sealed enclosure and rely on defined cabinet air conditions.

Path 02

External heatsink

Power-stage heat conducts to the rear heatsink where it can leave the cabinet boundary instead of accumulating inside.

Path 03

220 V blower

The assigned blower moves air across the external heatsink; the W1 supply identity must remain with the controller record.

Practical checks

Common Questions

01Before power-up, which blower checks are required for KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1?

For service work on KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, confirm the W1 220 V, 50–60 Hz blower supply and free airflow through the external heatsink.

02Which motor and feedback records establish the correct pairing for KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1?

Before work begins on KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, match the 2AD or 1MB motor plate, feedback type and programming-module identity with the controller model.

03Which type-plate and current-class details distinguish the two frames of KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1?

On KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, compare the complete type plates because the 100 A and 150 A frames have different current boundaries even though their control architecture is related.

04When a cabinet containing KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1 overheats, which cooling conditions should be checked?

For commissioning records for KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, check internal temperature, blower operation, heatsink obstruction and the installed controller current class.

05If spindle torque is weak on KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, what can be compared before any parameter is altered?

With KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, compare command value, feedback stability, DC-bus condition and the exact programming-module state.

06Which functions are shared by KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, and which current limits remain different?

For a site record covering KDA3.3-100-3-A00-W1 and KDA3.3-150-3-A00-W1, recognize that both frames use a 300 V DC bus, analog command processing and W1 forced cooling while their rated and continuous currents remain different.

Main-spindle drive record support

Our Services

Moore Automation

https://www.mvme.cn

Moore Automation supports multi-line enquiries for industrial automation products by keeping each complete main-spindle controller code visible through document and quotation preparation.

For the KDA3.3 pair, the 100 A and 150 A records, requested product documents, packing information and delivery destination can be coordinated without merging the two frames.

Model reviewEach KDA current frame retained
Document coordinationAvailable records tied to the exact line
Quotation preparationQuantities kept frame-specific
Delivery follow-upPacking and tracking communicated together

Enquiry Information

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.