Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>B&R>B&R X20BC0043 / X20BC0053 / X20BC0063 X20 Fieldbus Bus Controllers
B&R X20BC0043 / X20BC0053 / X20BC0063 X20 Fieldbus Bus Controllers

B&R X20BC0043 / X20BC0053 / X20BC0063 X20 Fieldbus Bus Controllers Item NO.: 2943226

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name B&R X20BC0043 / X20BC0053 / X20BC0063 X20 Fieldbus Bus Controllers
Item NO. 2943226
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-20

B&R X20BC0043 / X20BC0053 / X20BC0063 X20 Fieldbus Bus Controllers

FIELDBUS GATEWAY / X2X LINK

B&R X20BC0043 / X20BC0053 / X20BC0063 X20 Fieldbus Bus Controllers

CANopenDeviceNetPROFIBUS DP
Product dossier

Model Overview

B&R X20BC0043, X20BC0053 and X20BC0063 are X20 bus controllers that connect an X2X Link I/O station to three different host networks. X20BC0043 presents the station as a CANopen slave, X20BC0053 operates as a DeviceNet adapter, and X20BC0063 operates as a PROFIBUS DP slave; each controller translates the selected fieldbus exchange into cyclic access to the attached X20 modules.

The external network enters X20BC0043 or X20BC0053 through a five-position CAN-family connector, while X20BC0063 uses a nine-pin female DSUB for the RS485 PROFIBUS segment. Address switches identify the station on the respective network, and the integrated termination arrangement applies to the actual fieldbus end rather than to the downstream X2X modules.

Downstream from X20BC0043, X20BC0053 or X20BC0063, X20 and other X2X-based modules form the local I/O node. The controller and I/O rails are supplied through an X20PS9400 or X20PS9402 on the matching base, so network configuration, node address, fieldbus termination and station power must all be correct before the host can exchange valid process data with the local modules.

Verified data

Technical Details

SpecificationX20BC0043X20BC0053X20BC0063
Host Network CANopen DeviceNet PROFIBUS DP
Fieldbus Role Slave Adapter / slave DP slave
Physical Connector 5-pin CAN multipoint connector 5-pin DeviceNet multipoint connector 9-pin female DSUB
Maximum Transfer Rate 1 Mbit/s 500 kbit/s 12 Mbit/s
Maximum Segment Distance 1000 m 500 m 1200 m
Network Address Node-number switches MAC ID switches, range 0–63; 64 for software setting Node-number switches
Termination Integrated, switchable Integrated, switchable External PROFIBUS connector termination
X2X Link Minimum Cycle 400 µs 400 µs 400 µs
Fieldbus Isolation CANopen isolated from I/O DeviceNet isolated from I/O PROFIBUS isolated from I/O
Power Consumption 1.5 W 1.5 W 2.3 W
Controller Power Module X20PS9400 or X20PS9402 X20PS9400 or X20PS9402 X20PS9400 or X20PS9402
Bus Base X20BB80 X20BB80 X20BB80
I/O Terminal Block X20TB12 X20TB12 X20TB12
Operating Temperature -25 to 60°C horizontal; -25 to 50°C vertical -25 to 60°C horizontal; -25 to 50°C vertical -25 to 60°C horizontal; -25 to 50°C vertical

Fieldbus-to-X2X Data Route

Each controller terminates a different host protocol but exposes one local X2X station behind it.

01

CANopen object exchange

X20BC0043 receives CANopen process and service communication on the host side, maps the configured station data, and moves the resulting values through X2X Link to the local modules. The host address and baud rate must match the CANopen network.

02

DeviceNet connection model

X20BC0053 builds explicit and I/O connections with the scanner and can automatically detect the transfer rate. Its auto-scan and mapping functions organize attached modules, but valid DeviceNet voltage and a completed master connection remain separate status conditions.

03

PROFIBUS cyclic station

X20BC0063 presents the modular station to a DP master using its device description and configured module order. The DP address binds the physical controller to the host configuration while X2X Link continues serving local I/O.

Commissioning Boundaries

Address, termination, power and local module order must be checked at their own boundaries instead of as one general bus fault.

01

Host-side address

The rotary switches on X20BC0043, X20BC0053 and X20BC0063 identify the fieldbus station. A correct local X2X configuration cannot compensate for an address that differs from the master project.

02

Segment end and connector

CANopen and DeviceNet use the appropriate five-wire connection and termination at the CAN segment ends; PROFIBUS uses the DSUB network connector and RS485 termination. The methods are protocol-specific and should not be interchanged.

03

Local station power

The bus controller, X2X Link and I/O supply are established by the base, power module and terminal block. Fieldbus LEDs can be present while a downstream I/O module remains unavailable because its local power or configured position is wrong.

Field questions

Customer Questions

What should be compared when X20BC0063 waits for configuration?

Compare the physical module sequence behind X20BC0063 with the PROFIBUS master configuration and device description. Also confirm the node-number switches and the DSUB connection before treating the condition as an I/O-module fault.

Why can local I/O remain missing behind X20BC0043, X20BC0053 or X20BC0063 after the host bus starts?

For X20BC0043, X20BC0053 or X20BC0063, check the X20PS9400/9402 supply, X20BB80 base, X20TB12 wiring and configured module order. Host communication and downstream X2X availability are related but separately diagnosed.

Can X20BC0043 be connected directly to a DeviceNet scanner?

No. X20BC0043 is a CANopen slave, while X20BC0053 is the DeviceNet adapter in this group. Although both use CAN signaling, their application protocols and master configuration are different.

Which connector change is required when moving from X20BC0053 to X20BC0063?

A station using X20BC0053 has a five-position DeviceNet connection, whereas X20BC0063 uses a nine-pin female DSUB PROFIBUS connection. The network cable, termination method and master configuration must all change with the protocol.

Why does X20BC0053 show no DeviceNet connection even though its module LED is active?

For X20BC0053, verify the external 24 V DeviceNet supply, NET LED, detected transfer rate, MAC ID and scanner connection. Module power alone does not establish a DeviceNet explicit or I/O connection.

Where should termination be enabled for X20BC0053?

Enable the integrated resistor on X20BC0053 only when the controller is at a DeviceNet segment end. The switch on the housing and the TERM indication apply to the DeviceNet trunk, not the X2X Link station.

Moore Automation

Multi-Protocol Order Review

Moore Automation

https://www.mvme.cn/

Moore Automation keeps visually similar controller variants separated by their complete order number and communication protocol.

Protocol checkThe requested host network is recorded before model comparison.
Connector scopeNetwork plugs and terminal blocks remain separate accessory lines.
Station contextPower module and base requirements stay linked to the controller request.
Revision claritySuffix and hardware details are preserved when supplied by the customer.

Sales Contact

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.