Shared energy stage
Mains is rectified once inside 8EI2X2HWD10.0600-1. The resulting DC bus becomes the common energy source for both axis inverters.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | B&R Industrial Automation 8EI2X2HWD10.0600-1 ACOPOS P3 Dual-Axis Servo Drive |
| Item NO. | 2944888 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | B&R |
| Brand | B&R |
| Creation Time | 2026-11-25 |
B&R Industrial Automation 8EI2X2HWD10.0600-1 is an ACOPOS P3 wall-mounted dual-axis servo drive. One housing contains the mains rectifier and DC bus together with two motor-output channels, allowing two servo axes to share the incoming power stage while retaining separate motor, brake, temperature and encoder connections.
Inside 8EI2X2HWD10.0600-1, the 470 µF DC bus supplies both inverter channels. Axis 1 terminates at the X51 motor path and Axis 2 at X52, while X41 and X42 return the respective motor-feedback and temperature information; this pairing prevents one axis channel from being commissioned against the other motor’s feedback.
Control power for 8EI2X2HWD10.0600-1 enters independently of the mains connection and supports both brake circuits, trigger inputs and enable inputs. POWERLINK provides the real-time network path, while status for each axis remains associated with its own motor and encoder connectors even though the two channels share the module housing and DC bus.
| Attribute | 8EI2X2HWD10.0600-1 |
|---|---|
| Brand | B&R Industrial Automation |
| Product Type | ACOPOS P3 dual-axis servo drive |
| Brand Country | Austria |
| Mains input | 3 × 200 to 480 VAC ±10% |
| Installed load | Maximum 5 kVA |
| DC-bus continuous power | 2 kW |
| DC-bus capacitance | 470 µF |
| Control supply | 24 VDC ±25% |
| Motor outputs | 2 independent connections |
| Current per motor connection | 2.2 A continuous; 6 A peak |
| Peak power output | 2.5 kW per module class |
| Switching frequencies | 5, 10 or 20 kHz; 5 kHz nominal |
| Encoder inputs | 2 digital EnDat 2.2 interfaces |
| Dimensions / weight | 66 × 374 × 258.5 mm / 4 kg |
8EI2X2HWD10.0600-1 shares rectification and stored DC energy, but its two inverter outputs remain distinct all the way to their motor connectors.
Axis 2 output — The second inverter of 8EI2X2HWD10.0600-1 terminates at X52 with feedback on X42. Sharing the bus does not combine the two motor phases or encoder returns.
Mains is rectified once inside 8EI2X2HWD10.0600-1. The resulting DC bus becomes the common energy source for both axis inverters.
The first inverter of 8EI2X2HWD10.0600-1 drives the motor on X51 and uses the corresponding feedback path on X41. Its current and temperature state are evaluated as Axis 1.
Each motor channel on 8EI2X2HWD10.0600-1 carries its own feedback and holding-brake information even though the 24 V source is common to the module.
X41 belongs to Axis 1 and X42 to Axis 2 on 8EI2X2HWD10.0600-1. Commissioning must preserve those pairs from the motor cable through the configured axis object.
The two brake outputs of 8EI2X2HWD10.0600-1 are assigned per motor connection. Their combined load is included in the module’s 24 V supply budget.
POWERLINK carries commands and status for both axes of 8EI2X2HWD10.0600-1, but diagnostic interpretation still follows the individual axis channel.
Motor-temperature information remains paired with the X41 and X42 feedback paths of 8EI2X2HWD10.0600-1, preventing a thermal condition on one motor from being assigned to the other axis.
The two channels share mains and DC-bus hardware but keep separate encoder, temperature, brake and motor connections. A fault limited to one side of 8EI2X2HWD10.0600-1 should therefore be traced through that axis pair before the shared power stage is suspected.
Label the X51/X41 pair as Axis 1 and the X52/X42 pair as Axis 2 before commissioning 8EI2X2HWD10.0600-1. Verify one disabled axis at a time so a crossed motor and encoder pair is found before torque is enabled.
Use the complete 8EI2X2HWD10.0600-1 string and include a clear type-plate image. The family code 8EI2X2HWD10.XXXX-1 identifies the hardware range but does not preserve the configured suffix on the installed device.
Include the electronics consumption of 8EI2X2HWD10.0600-1 together with both connected motor holding brakes. Do not add the two motor phase currents because those are supplied from the DC-bus inverter stage.
First check the physical enable and common references on 8EI2X2HWD10.0600-1, then review POWERLINK node status and the individual axis state. A valid network connection does not by itself prove that both local enable paths are present.
The chosen switching frequency influences current derating and the permitted motor-cable conditions for 8EI2X2HWD10.0600-1. Confirm the configured frequency with the actual motor current and cable arrangement instead of treating 5, 10 and 20 kHz as interchangeable labels.
Moore Automation assigns one account contact to coordinate international industrial automation enquiries. The contact keeps manufacturer codes, requested quantities and documentation requirements together from review through quotation.
Lead-time information, carrier details and tracking updates are communicated against the same enquiry record.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found