Runtime and remanence
Automation Runtime on 4PPC70.0573-20W executes control tasks, while FRAM retains configured remanent variables independently of the display refresh path.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | B&R Industrial Automation 4PPC70.0573-20W Power Panel C70 Controller |
| Item NO. | 2944893 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | B&R |
| Brand | B&R |
| Creation Time | 2026-11-25 |
B&R Industrial Automation 4PPC70.0573-20W is a Power Panel C70 controller with a 5.7-inch landscape display. It combines a fanless controller, visualization engine and analog resistive touch surface in one cabinet-mounted unit, while its C70 processor executes Automation Runtime and connects the HMI to the machine network.
The 640 × 480 display of 4PPC70.0573-20W is backed by 256 MB DRAM, 32 kB FRAM and 2 GB onboard flash. Touch coordinates enter the visualization locally, while POWERLINK, Ethernet and X2X Link each retain a separate rear connector and communication role.
A 24 VDC feed powers 4PPC70.0573-20W through its terminal block, and the front frame forms the IP65 boundary at the cutout. The aluminum-white W front differs in finish from the B variant; it does not add the fieldbus connectors found in the -21, -22 or -23 C70 variants.
| Attribute | 4PPC70.0573-20W |
|---|---|
| Brand | B&R Industrial Automation |
| Product Type | Power Panel C70 controller |
| Brand Country | Austria |
| Display | 5.7-inch TFT, landscape |
| Resolution | 640 × 480 VGA |
| Touch technology | Analog resistive |
| Processor | Atom E620T, 333 MHz compatible |
| Memory | 256 MB DRAM; 32 kB FRAM; 2 GB flash |
| Interfaces | POWERLINK, Ethernet, X2X Link, 2 × USB |
| Supply voltage | 24 VDC -15% / +20% |
| Maximum power | 14.5 W |
| Front design | Aluminum-white pinstripe |
| Dimensions | 172 × 140 × 51 mm |
| Protection | Front IP65 / back IP20 |
4PPC70.0573-20W keeps the controller, nonvolatile memory and visualization engine behind a compact VGA touch surface.
Fanless heat path — 4PPC70.0573-20W relies on passive cooling through the installed panel assembly. Rear clearance and the permitted mounting orientation therefore form part of the thermal path.
Automation Runtime on 4PPC70.0573-20W executes control tasks, while FRAM retains configured remanent variables independently of the display refresh path.
The HMI of 4PPC70.0573-20W is rendered from onboard application storage through the 640 × 480 display controller, and touch coordinates return through the local serial touch controller.
The rear of 4PPC70.0573-20W separates supply, deterministic networking, standard Ethernet, local I/O and USB peripheral wiring.
The 24 VDC terminal supplies 4PPC70.0573-20W, while the front gasket provides the protected boundary only when the panel is installed in the specified cutout.
POWERLINK carries real-time network traffic, Ethernet carries standard communication and X2X Link connects local I/O for 4PPC70.0573-20W.
The resistive surface of 4PPC70.0573-20W does not use an external fieldbus. Its coordinates are processed inside the panel before the application receives them.
On 4PPC70.0573-20W, standard Ethernet remains the service and general communication path while POWERLINK retains the deterministic network role.
Use the standard Ethernet interface for ordinary 10/100 communication and keep the POWERLINK connector assigned to its deterministic network. Check the interface labels on 4PPC70.0573-20W before moving an RJ45 cable because both ports use similar connectors.
4PPC70.0573-20W uses a 640 × 480 VGA canvas. A project prepared for a wider C70 panel can place buttons or text outside that boundary even when the controller program itself is compatible.
Review the supply and operating-state indicators on 4PPC70.0573-20W and check whether the unit is still visible on its configured network. A controller that communicates with no image points to the display path, while no status or network activity starts the check at the 24 V feed.
Install 4PPC70.0573-20W in the specified flat cutout and tighten the retaining hardware evenly against the front gasket. Front IP65 does not extend to the rear housing or to an opening that is oversized or uneven.
Confirm the 640 × 480 landscape orientation and recalibrate the analog resistive touch path for 4PPC70.0573-20W. If the shift is uniform, calibration and orientation should be checked before replacing the panel.
The W ending identifies the aluminum-white pinstripe front on 4PPC70.0573-20W. It should not be interpreted as an added communication interface because fieldbus options are defined by the preceding numeric suffix.
Moore Automation supports enquiries for current, rare and obsolete industrial automation components from established manufacturers. Exact part numbers and requested documentation are recorded so discontinued and nearby active variants remain distinct.
One account contact coordinates available commercial information and shipment updates.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found