Shared processing
Both 4PPC70.101G-20B and 4PPC70.101N-20B use the same processor, DRAM, FRAM and onboard flash organization, so orientation does not create a different controller architecture.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | B&R Industrial Automation 4PPC70.101G-20B / 4PPC70.101N-20B Power Panel C70 Controllers |
| Item NO. | 2944892 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | B&R |
| Brand | B&R |
| Creation Time | 2026-11-25 |
B&R Industrial Automation 4PPC70.101G-20B and B&R Industrial Automation 4PPC70.101N-20B are Power Panel C70 controllers with a 10.1-inch resistive-touch display. Each unit combines an Atom-based Automation Runtime controller, onboard flash and FRAM with the HMI, so control execution, visualization and field communication meet at the cabinet-mounted panel.
The two products rotate the same 1024 × 600 pixel canvas into different mechanical formats. 4PPC70.101G-20B is the 276 × 172 mm landscape assembly, while 4PPC70.101N-20B is the 172 × 276 mm portrait assembly; their rear connector field follows the corresponding mounting direction even though processor, memory and base interfaces remain the same.
On both 4PPC70.101G-20B and 4PPC70.101N-20B, POWERLINK carries deterministic network traffic, the separate Ethernet port serves standard 10/100 Mbit/s communication, and X2X Link extends local I/O. The two USB ports and 24 VDC supply terminate at the rear, while the front sealing boundary remains at the cabinet cutout.
| Attribute | 4PPC70.101G-20B | 4PPC70.101N-20B |
|---|---|---|
| Brand | B&R Industrial Automation | B&R Industrial Automation |
| Product Type | Power Panel C70 controller | Power Panel C70 controller |
| Brand Country | Austria | Austria |
| Orientation | Landscape | Portrait |
| Display / resolution | 10.1-inch / 1024 × 600 | 10.1-inch / 600 × 1024 |
| Touch technology | Analog resistive | Analog resistive |
| Processor | Atom E620T, 333 MHz compatible | Atom E620T, 333 MHz compatible |
| Memory | 256 MB DRAM; 32 kB FRAM; 2 GB flash | 256 MB DRAM; 32 kB FRAM; 2 GB flash |
| Interfaces | POWERLINK, Ethernet, X2X Link, 2 × USB | POWERLINK, Ethernet, X2X Link, 2 × USB |
| Supply / maximum power | 24 VDC -15% / +20% / 14.5 W | 24 VDC -15% / +20% / 14.5 W |
| Operating temperature | 0 to 50°C | 0 to 50°C |
| Dimensions | 276 × 172 × 51 mm | 172 × 276 × 51 mm |
| Weight | 1.05 kg | 1.05 kg |
| Protection | Front IP65 / back IP20 | Front IP65 / back IP20 |
4PPC70.101G-20B and 4PPC70.101N-20B share controller hardware while their front frame, cutout orientation and coordinate system are rotated.
Mechanical rotation — The width and height of 4PPC70.101G-20B become the height and width of 4PPC70.101N-20B. The cabinet opening and connector access therefore must be checked in the intended orientation.
Both 4PPC70.101G-20B and 4PPC70.101N-20B use the same processor, DRAM, FRAM and onboard flash organization, so orientation does not create a different controller architecture.
4PPC70.101G-20B presents 1024 × 600 in landscape; 4PPC70.101N-20B presents the corresponding 600 × 1024 portrait space. HMI object placement must follow that coordinate system.
The C70 controller receives touch coordinates locally while network and I/O traffic enter through dedicated rear interfaces.
The resistive surface on 4PPC70.101G-20B or 4PPC70.101N-20B is processed by the panel touch controller before coordinates reach the visualization application.
POWERLINK and standard Ethernet on 4PPC70.101G-20B and 4PPC70.101N-20B are separate physical interfaces, so their traffic roles should not be interchanged in wiring documents.
X2X Link on 4PPC70.101G-20B and 4PPC70.101N-20B connects the controller to supported local I/O stations, while USB remains a separate peripheral connection.
The USB connectors on 4PPC70.101G-20B and 4PPC70.101N-20B serve local peripherals and do not replace the POWERLINK, Ethernet or X2X Link wiring paths.
Use the supply, operating-state, module-status, POWERLINK and Ethernet indicators on 4PPC70.101G-20B or 4PPC70.101N-20B. Their combination shows whether the problem is at 24 V power, controller startup or a particular network path.
Use the interface labels and network plan: POWERLINK is the deterministic fieldbus port, while the second RJ45 is standard 10/100 Ethernet. Link activity alone on 4PPC70.101G-20B or 4PPC70.101N-20B does not prove the cable is on the intended network.
Review the visualization for a 1024 × 600 landscape canvas on 4PPC70.101G-20B versus a 600 × 1024 portrait canvas on 4PPC70.101N-20B. Also rotate the cabinet cutout and verify rear cable access instead of only changing a screen-orientation setting.
Confirm that the configured panel orientation matches the physical orientation of 4PPC70.101G-20B or 4PPC70.101N-20B, then run the applicable resistive-touch calibration. A rotated visualization with an unrotated touch map produces consistent but displaced coordinates.
The cutout dimensions contain the same two nominal sides, but their orientation is reversed between 4PPC70.101G-20B and 4PPC70.101N-20B. Existing door hardware, cable ducts and adjacent devices must still be checked after rotation.
The two USB ports on 4PPC70.101G-20B and 4PPC70.101N-20B have defined current capacities. Include the peripheral load in the 24 V supply and power-consumption review rather than assuming every bus-powered device can be connected simultaneously.
Moore Automation coordinates international shipment information through the account contact assigned to each enquiry. Available carrier details, tracking information and dispatch updates are communicated against the exact product record.
Secure packaging requirements can be recorded together with the destination and requested documentation.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found