2 MB controller for integrated EtherNet/IP motion
Allen-Bradley 5069-L320ERM CompactLogix 5380 Controller with Integrated Motion
Dual 1 Gb Ethernet ports, 16 local I/O modules and eight motion axes.
Product Description
For machines that need coordinated motion without a separate motion controller, the Allen-Bradley 5069-L320ERM combines Logix control with eight integrated motion drive axes over EtherNet/IP.
Its 2 MB user memory supports as many as 16 local Compact 5000 I/O modules and 40 EtherNet/IP nodes. Two Ethernet ports can be arranged for linear, Device Level Ring or Dual-IP network designs.
The 5069-L320ERM mounts horizontally on DIN rail and uses separate MOD and SA power connections, so the controller and field-side I/O supply can be segmented during commissioning and maintenance.
Technical Specifications
| Technical Item | 5069-L320ERM |
|---|---|
| Brand | Allen-Bradley |
| Product Type | CompactLogix 5380 motion controller |
| Brand Country | United States |
| User Memory | 2 MB |
| Local I/O Modules | 16 maximum |
| EtherNet/IP Nodes | 40 maximum |
| Integrated Motion Axes | 8 drive axes |
| Ethernet Ports | 2 × 10/100/1000 Mb/s |
| MOD Power | 18…32 V DC; 450 mA maximum |
| Power Dissipation | 8.5 W maximum |
| Dimensions (H × W × D) | 143.97 × 98.10 × 136.81 mm |
| Weight | 0.768 kg |
| Relative Humidity | 5…95%, noncondensing |
Integrated Motion Capacity
Coordinate eight drive axes on EtherNet/IP
- Configure as many as eight integrated motion drive axes while retaining the standard controller task model.
- Place motion drives on the EtherNet/IP path supported by the controller and budget every device against the 40-node ceiling.
- Use time-synchronized network design and validated drive update rates when axis coordination depends on deterministic timing.
- The 2 MB memory and 16-module local-I/O allowance set the practical boundary for machine logic, motion objects and local signals.
Controller Power & Expansion Limits
Separate controller power from field-side load planning
- Feed MOD power with 18…32 V DC and reserve for the 450 mA maximum controller demand plus startup inrush.
- Size SA power for the attached Compact 5000 I/O field circuits rather than assuming the controller rating covers downstream loads.
- Mount the controller on a horizontal DIN rail and keep the required end-cap and bank arrangement.
- The dimensional figure provides the enclosure envelope before cable bend space and ventilation clearances are added.
Frequently Asked Questions
Why can 5069-L320ERM accept a new drive but refuse another motion axis?
The controller has separate limits for EtherNet/IP nodes and integrated motion axes. Count configured drive axes against the eight-axis limit and all network devices against the 40-node limit before changing the project.
Can 5069-L320ERM use both Ethernet ports as two independent plant networks?
Yes when Dual-IP mode is supported and configured, but each port then requires its own IP settings and network plan. Do not bridge two existing networks accidentally; confirm the selected Ethernet mode before connecting the second cable.
What should be checked when 5069-L320ERM resets as several I/O modules energize?
Measure MOD and SA power separately during startup and compare inrush and steady-state load with the supply capacity. A healthy controller supply does not prove the field-side SA source can support the attached module bank.
Does 5069-L320ERM support more than 16 local Compact 5000 I/O modules through another adapter?
The local bank beside the controller is limited to 16 modules. Additional distributed I/O can be placed behind supported EtherNet/IP adapters, but those adapters and devices consume network-node capacity.
Why does 5069-L320ERM lose coordinated motion after a network topology change?
Check that the new topology preserves time synchronization, drive paths and ring-supervisor settings where DLR is used. Also verify that switch features and multicast handling are appropriate for the motion traffic.
How much enclosure space should be reserved for 5069-L320ERM?
Start with the published 143.97 × 98.10 × 136.81 mm controller envelope, then add wiring bend radius and required clearances. The dimension figure is the equipment size, not the complete panel-space allowance.
Inventory Coordination
Moore Automation
Warehouse checks tied to the requested suffix
Moore Automation reviews the full catalog number before inventory and quotation work begins. That suffix-level check is useful when controller families share the same base number but differ in motion or safety capability.
Send the complete part number and quantity so the requested variant remains clear from enquiry through quotation.
Recommended Products
- Brevini 1019-1012-0051
- Brinkmann SFL1150/780-CM1
- Cisco TPSN-50AB
- Crestron C2N-IO
- Datalogic MX4000-1000
- DEIF PPU/2/GS
- Euchner ZSA2A1G10A
- FERMAX 2419
- Grundfos CRT16-5-E-FGJ-A-E-AUUE
- Hager CD440S
- Heidenhain LS704C23713414
- Hirschmann 5TX
- HORA C408
- Inspiroy H950P
- Intermec 98087
- Kissling 65.B12.112D
- KUKA 00-183-005
- Leuze MLC530R14-1500
- Mersen OTS125
- Merten 644992
- MTL 4541AS
- Pepperl+Fuchs Z787
- Prok EL05
- Sauter 0930240541
- Siba 2000204.35
- SINEAX DME442
- Stöber K713SG0230MQ40
- SYSTIMAX 760028373
- Tecsis P3251B086654
- Theben TR614
- Turck MK13-12Ex0-DZ/230VAC
- Wenglor OPT104
- White A-0085-WHITE
- WIKA 0-300PSI
- Wilo DL200/240-15/4
- ACI A/CTE-50
- Siemens 3RM1207-1AA04
- ABB 1SAZ211201R1031
- Allen-Bradley 889D-F4AC-2
- Honeywell 5894PI
- Festo DGPL-40-1550-PPV-A-HD40-GK
- Schneider PM2200
- WAGO 750-343
- B&R X20DI9371
- Beckhoff KL9510
- Rexroth PV7-18/100-118RE07MC0-16
- GE D7130WDMA
- Lenze MCA19S35-SRSF2-B28R-KS5F12N-R0SU
- Legrand 574644
- Brady PTL-8-439-RD
- ifm IG5398
- SEW DFY112L/B/TH/XV2A/SM41
- SMC ECXSM25-50
- SICK C40S-1803CA010
- Weidmüller 1478110000
- Baumüller DAF132K-23A30-5
- Bosch SD-B6.480.020-15.000
- Indramat MAC112C-0-HD-4-C/180-A-2/WI520LV/S029
- KEB 20F4F3R-4R01
- Omron S8VS-01524
Contact Us
Send the complete part number and quantity for a quotation.









No related record found