Compact controller for networked machine control
Allen-Bradley 5069-L310ER CompactLogix 5380 Standard Controller
1 MB memory, eight local I/O modules and 24 EtherNet/IP nodes.
Product Description
A compact control platform for smaller networked machines, the Allen-Bradley 5069-L310ER offers 1 MB user memory with capacity for eight local Compact 5000 I/O modules.
The controller manages up to 24 EtherNet/IP nodes through two 1 Gb ports and provides a USB 2.0 Type-B connection for temporary local programming and maintenance.
Because 5069-L310ER is a standard, non-motion catalog, selection should be based on logic, local I/O and network capacity rather than an expectation of integrated motion axes.
Technical Specifications
| Technical Item | 5069-L310ER |
|---|---|
| Brand | Allen-Bradley |
| Product Type | CompactLogix 5380 standard controller |
| Brand Country | United States |
| User Memory | 1 MB |
| Local I/O Modules | 8 maximum |
| EtherNet/IP Nodes | 24 maximum |
| Integrated Motion Axes | Not supported |
| Ethernet Ports | 2 × 10/100/1000 Mb/s |
| USB Port | USB 2.0 Type B; 12 Mb/s |
| MOD Power | 18…32 V DC; 450 mA maximum |
| Power Dissipation | 8.5 W maximum |
| Weight | 0.768 kg |
| Dimensions (H × W × D) | 143.97 × 98.10 × 136.81 mm |
Local Programming Ports
Use USB only for temporary engineering access
- The front USB 2.0 Type-B port operates at 12 Mb/s for local programming, firmware and diagnostic work.
- Keep the USB cable at or below 3 m and connect directly; hubs are not part of the documented connection.
- USB is not intended as a permanent control or production communication link.
- Use the Ethernet ports for the operating controller network and reserve USB for attended maintenance.
Linear and DLR Network Topology
Choose the port mode before wiring the machine
- In linear or Device Level Ring mode, both embedded ports participate in the same network path.
- A DLR design needs a correctly configured ring supervisor and a complete ring so a single cable break can be detected and recovered.
- Dual-IP uses separate network identities and must not be treated as an unmanaged bridge.
- Keep the complete controller project within the 24-node limit after adapters, drives, HMIs and other configured devices are counted.
Frequently Asked Questions
Can 5069-L310ER run integrated motion after a firmware upgrade?
No; integrated motion capability is determined by the controller catalog, not added by firmware. Select an ERM catalog when coordinated integrated drive axes are part of the application.
Why is Studio 5000 unable to reach 5069-L310ER over USB?
Use a direct USB 2.0 Type-B cable no longer than 3 m and confirm that the controller is powered and the local driver is available. Remove any USB hub and treat the connection as temporary local access.
What happens if 5069-L310ER is connected to two switches while still in linear/DLR mode?
Both ports belong to the same configured topology, so an unintended loop can be created if the surrounding network is not designed for DLR. Confirm the port mode and ring supervision before closing the second path.
How should the 24-node limit of 5069-L310ER be counted?
Count EtherNet/IP devices added to the controller I/O configuration, including communication adapters and drives. Do not confuse physical switch ports or unconfigured engineering computers with configured controller nodes.
Can 5069-L310ER carry more than eight I/O modules directly beside it?
No; its local Compact 5000 I/O bank is limited to eight modules. Use distributed I/O over EtherNet/IP when more points are required and include the added adapter in the node budget.
Why does 5069-L310ER communicate locally but not through the plant network?
A direct USB session bypasses the Ethernet addressing and topology, so it can succeed while IP settings are wrong. Check port mode, IP address, subnet, gateway and any DLR or managed-switch configuration from the controller display and project.
Technical Response Service
Moore Automation
Useful answers start with the whole catalog number
Moore Automation keeps technical and commercial questions attached to the same enquiry. Buyers can submit the complete model, quantity and application concern so close controller variants are not mixed during follow-up.
Send the complete part number and quantity so the requested variant remains clear from enquiry through quotation.
Recommended Products
- Eaton C320KGS3
- Finder 83.62.0.240.0000
- Herion 2381108
- Keyence PX-10P
- Parker 07E32A13AC9
- Phoenix Contact 2320018
- Yaskawa CIMR-AC4A0058AAA-0121
- CAREL PGD1000F00
- Krones 0-903-95-169-8
- Danfoss VLT6052HT4C54STR3DLF10A00C0
- Lapp 4160414K
- Murr 7000-99601-0000000
- Notifier FSM500
- Roemheld 1940826
- Aventics 0820031051
- Delta TP70P-22XA1R
- Emerson 3A99266G01
- EMG 17-REL/KSR-24/21-21-LC
- Extron 60-652-01
- FISCHER DE455700P8PK03MW
- Foxboro 3A2-I3D
- Huion HS64
- Hydac SB330-20A1/112U-330A
- Mitsubishi QX40
- Moeller NZM7-100N-M
- Motorola RMN5111B
- Norgren 2432575134402400
- Pilz 506400
- PULS SL10.100
- Schunk OSE-A22-4
- TRUMPF 2655705
- Wieland 57.535.9055.0
- ZIEHL-ABEGG ER40C-2DN.G7.CR
- AEG bw117
- Siemens 3RU2126-4EB0
- ABB 1SDA054873R1
- Allen-Bradley 1756CPR2
- Honeywell NetAXS-123
- Festo DGC-K-32-2500-PPV-A-GK
- Schneider 56C315RP
- WAGO 750-842
- B&R X20DO4529
- Beckhoff KL4032
- Rexroth MDD093C-N-020-N2M-110PR2
- GE IC693MDL742D
- Lenze MCA19S35-RS0F3-Z0G0-ST5F30N-R0SU
- Legrand 573033
- Brady 42104
- ifm IM5115
- SEW MDS60A0370-503-4-0T
- SMC MXS25-20
- SICK C40S-1801AA030
- Weidmüller 2580230000
- Baumüller BUM62T-100/130-54-M-019
- Bosch SD-B6.480.020-00.000
- Indramat MAC112D-0-ED-C/130-A-1/WI565/S05
- KEB 17F4C1H3440
- Omron H3DE-S1
- Eaton DG1-34140FN-C21C
- Finder 19.21.0.024.0000
Contact Us
Send the complete part number and quantity for a quotation.









No related record found