V33 flexible phase input
2097-V33PR1-LM accepts 120/240 V AC in single- or three-phase form and produces 0.5 kW continuous output.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Allen-Bradley 2097-V33PR1-LM / 2097-V34PR3-LM Kinetix 350 multi-phase EtherNet/IP servo drives |
| Item NO. | 2913267 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | AB |
| Brand | ALLEN-BRADLEY |
| Creation Time | 2026-10-08 |
Allen-Bradley 2097-V33PR1-LM / 2097-V34PR3-LM are Kinetix 350 EtherNet/IP servo drives whose catalog numbers define different mains-voltage classes. V33PR1 uses 120/240 V AC, single- or three-phase input and supplies 0.5 kW, while V34PR3 uses 480 V AC three-phase input and supplies 1.0 kW. Neither catalog number includes the V32 integrated AC line filter, so filtering remains an installation selection.
Power entering 2097-V33PR1-LM / 2097-V34PR3-LM is rectified to the model-specific DC bus before the inverter produces the motor output. Both units provide 2.0 A rms continuous and 6.0 A rms peak current, but their shunt thresholds, input current, line protection, and compatible supply wiring follow the V33 or V34 voltage code. This is why a common current value cannot be used as a replacement rule.
For control integration, 2097-V33PR1-LM / 2097-V34PR3-LM exchange commands and status over EtherNet/IP while motor feedback and safe torque-off use dedicated interfaces. Because the output-current class is the same, the full model number is essential to prevent a 120/240 V drive from being mistaken for a 480 V drive. The configured axis must still match the motor and installed supply hardware.
| Technical Item | 2097-V33PR1-LM / 2097-V34PR3-LM |
|---|---|
| Brand | Allen-Bradley |
| Product Type | Single-axis EtherNet/IP servo drive |
| Brand Country | United States |
| Product Family | Kinetix 350 |
| V33 AC Input | 120/240 V rms, single- or three-phase |
| V34 AC Input | 480 V rms, three-phase |
| AC Input Frequency | 48–62 Hz |
| Continuous Power Output | 2097-V33PR1-LM: 0.50 kW; 2097-V34PR3-LM: 1.00 kW |
| Continuous Output Current | 2.0 A rms for both models |
| Peak Output Current | 6.0 A rms for both models |
| Nominal AC Input Current | V33 at 240 V: 3.0 A; V34 at 480 V: 2.7 A |
| Integrated AC Line Filter | No |
| Control Power Backup | 20–26 V DC; 500 mA nominal |
| Shunt Switching | V33: 390/375 V DC; V34: 780/750 V DC |
| Controller Interface | EtherNet/IP |
| Safety Interface | Safe torque-off |
| Weight | 1.3 kg / 1.5 kg |
| Maximum Power Loss | 28 W / 39 W |
2097-V33PR1-LM accepts 120/240 V AC in single- or three-phase form and produces 0.5 kW continuous output.
2097-V34PR3-LM accepts 480 V AC three-phase input and produces 1.0 kW while retaining the same 2.0 A rms continuous-current class.
The V33 shunt switches at 390/375 V DC, whereas the V34 stage switches at 780/750 V DC; the two supply classes are not interchangeable.
2097-V33PR1-LM / 2097-V34PR3-LM use common control-interface roles even though their incoming power circuits are different.
The controller project communicates over EtherNet/IP and must retain the full catalog number so the installed voltage class remains visible.
Motor position data enters the dedicated feedback connector and is processed locally by the drive control loop.
Safe torque-off wiring acts on the drive output stage independently of normal EtherNet/IP commands and the main AC contactor sequence.
Both drives deliver 2.0 A rms continuously, but 2097-V33PR1-LM is a 120/240 V single- or three-phase unit and 2097-V34PR3-LM is a 480 V three-phase unit. Their rectifier, DC-bus, shunt, protection, and supply wiring requirements differ. This requirement covers 2097-V33PR1-LM / 2097-V34PR3-LM.
For equipment identified as 2097-V33PR1-LM / 2097-V34PR3-LM, use 0.5 kW for 2097-V33PR1-LM and 1.0 kW for 2097-V34PR3-LM. The identical current value does not create an identical power rating because the available voltage at the motor output differs.
No. V34 identifies the 480 V rms three-phase input class. A 240 V single-phase installation requires an appropriate V31, V32, or V33 catalog selection rather than a wiring adaptation to V34. The models covered are 2097-V33PR1-LM / 2097-V34PR3-LM.
Regarding 2097-V33PR1-LM / 2097-V34PR3-LM, their DC buses correspond to different line-voltage classes. V33 switches at 390/375 V DC, while V34 switches at 780/750 V DC, so regenerative components and fault expectations must follow the installed model.
It proves that the controller-data path is operating. It does not prove that motor power, motor feedback, STO, or the supply phase arrangement is correct; each of those circuits must be checked independently. This distinction applies to 2097-V33PR1-LM / 2097-V34PR3-LM.
Within 2097-V33PR1-LM / 2097-V34PR3-LM, capture the complete catalog number, voltage and phase supply, motor catalog number, and existing line-filter/protection arrangement. The V33 or V34 code is particularly important because both pages can otherwise appear to describe a 2 A Kinetix 350 drive.
Moore Automation combines 100% original products, fast delivery, one-year warranty coverage and responsive order communication for industrial automation spare-parts enquiries.