BR supply boundary
The BR position permits 380–480 V AC or 513–620 V DC input and must not be confused with the lower- or higher-voltage catalog codes.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Allen-Bradley 1336F-BRF10-AA-EN 1336 PLUS II adjustable-frequency AC drive |
| Item NO. | 2913277 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | AB |
| Brand | ALLEN-BRADLEY |
| Creation Time | 2026-10-08 |
Allen-Bradley 1336F-BRF10-AA-EN is a 1336 PLUS II adjustable-frequency AC drive rated 0.75 kW (1 hp). Its complete catalog code identifies a BR 380–480 V AC or 513–620 V DC supply class, F10 power rating, AA IP20/NEMA 1 enclosure, and English-language configuration. The AA enclosure is intended for protected indoor installation rather than washdown or outdoor exposure.
In 1336F-BRF10-AA-EN, the input stage creates the internal DC bus and the inverter produces variable-frequency, variable-voltage motor output. Run commands, speed reference, status, and option communications use the control section, while the high-current motor terminals remain dedicated to the three-phase output path. The command source and speed-reference source must both agree with the active parameter configuration.
Replacement and commissioning of 1336F-BRF10-AA-EN depend on retaining every catalog position. BR prevents confusion with 230 V or 575 V hardware, F10 fixes the 1 hp rating, AA defines the finger-safe panel enclosure boundary rather than a sealed enclosure, and EN identifies the language group without changing the electrical rating. Any option or modification code on the nameplate must also remain attached.
| Technical Item | 1336F-BRF10-AA-EN |
|---|---|
| Brand | Allen-Bradley |
| Product Type | Adjustable-frequency AC drive |
| Brand Country | United States |
| Product Family | 1336 PLUS II |
| Bulletin Code | 1336F |
| Voltage Code | BR |
| AC Voltage Class | 380–480 V AC |
| DC Input Class | 513–620 V DC |
| Rating Code | F10 |
| Nominal Rating | 0.75 kW (1 hp) |
| Enclosure Code | AA |
| Enclosure Type | IP20 / NEMA Type 1 |
| Language Code | EN |
| Language Group | English |
| Power Function | Variable-frequency, variable-voltage motor control |
| Motor Output | Dedicated three-phase inverter output terminals |
| Control Path | Separate command, reference, and status terminals |
| Catalog Requirement | All code positions retained for exact identification |
The BR position permits 380–480 V AC or 513–620 V DC input and must not be confused with the lower- or higher-voltage catalog codes.
F10 identifies the 0.75 kW (1 hp) rating; motor current, overload, protection, and conductor sizing must follow that rating and the nameplate.
The drive varies output frequency and voltage to control the connected AC motor, while commands and references remain on the low-level control side.
Correct configuration of 1336F-BRF10-AA-EN begins with the complete catalog identity, motor nameplate data, command source, speed reference, acceleration/deceleration values, and protective limits.
Run, stop, direction, and other commands must be assigned to the installed terminal or communication option rather than inferred from the family name.
The selected analog, digital, preset, or communication reference must be scaled to the motor and process speed range before operation.
Motor voltage, frequency, current, and base speed values must agree with the connected motor, while the AA enclosure remains inside its IP20/NEMA 1 environmental boundary.
For 1336F-BRF10-AA-EN, consider the following. No. In this catalog structure, F10 is the 0.75 kW (1 hp) rating code. The BR portion identifies the 380–480 V AC or 513–620 V DC supply class; reading the digits without the catalog-code table can produce the wrong power selection.
When 1336F-BRF10-AA-EN is involved, no. AA is IP20/NEMA Type 1, intended for a protected indoor panel environment. It is not a sealed washdown enclosure, so any harsher environment requires a suitable external enclosure designed for that location.
Confirm the command source, active stop or interlock inputs, speed-reference source, drive-enable state, fault status, and motor-terminal wiring. An energized display proves control power is present, not that a valid run command and reference have reached the inverter. This guidance covers 1336F-BRF10-AA-EN.
On 1336F-BRF10-AA-EN, the drive uses motor voltage, frequency, current, and base-speed information to apply limits and scaling. Incorrect values can cause unsuitable current limiting, speed display, or protection even when the BR and F10 hardware codes are correct.
They should be separated. Motor-output conductors carry switched high-frequency current that can couple noise into analog references, encoder signals, and digital control wiring; use the specified grounding, shielding, and routing practice. The stated boundary applies to 1336F-BRF10-AA-EN.
Use 1336F-BRF10-AA-EN exactly, plus any separate option or modification codes shown on the nameplate. Omitting BR, F10, AA, or EN loses the voltage, power, enclosure, or language identity needed to match the installed drive.
Moore Automation supplies 100% original products and connects one-year warranty coverage to the order record, preserving product identification for subsequent customer communication.