Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>AB>Allen-Bradley 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A 1394C analog-servo multi-axis system modules
Allen-Bradley 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A 1394C analog-servo multi-axis system modules

Allen-Bradley 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A 1394C analog-servo multi-axis system modules Item NO.: 2913273

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A 1394C analog-servo multi-axis system modules
Item NO. 2913273
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-10-08

Allen-Bradley 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A | Moore Automation
Allen-Bradley1394 Analog Servo Motion Control

Allen-Bradley 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A 1394C analog-servo multi-axis system modules

Product Overview

Allen-Bradley 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A are Series C 1394 analog-servo system modules, not SERCOS modules. The -A suffix provides a traditional ±10 V DC analog reference interface for velocity or torque control, with SCANport available as a standard system interface. A Human Interface Module can be used for commissioning, auto tuning, and start-up prompting.

Three-phase 324–528 V AC enters 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A, and the system module creates the 530/680 V DC bus used by connected 1394 axis modules. The SJT05, SJT10, and SJT22 codes set 4/5 kW, 8/10 kW, and 17/22 kW continuous bus-power levels, respectively. The bus then supplies individual axis modules rather than connecting directly to the motors.

The system boundary grows across 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A: AC input current rises from 6.5 A to 13.0 A and 28.6 A, and the 22 kW model requires an external shunt because it has no internal shunt resistor. Analog reference, encoder feedback, logic power, DC-bus distribution, and motor output must remain distinct circuits. Series C also adds active soft-start current limiting during DC-link charging.

Technical Specifications

Technical Item 1394C-SJT05-A 1394C-SJT10-A 1394C-SJT22-A
Brand Allen-Bradley
Product Type Analog-servo multi-axis system module
Brand Country United States
Product Family 1394 Series C
Interface Suffix -A: traditional ±10 V DC analog interface
Control Modes Velocity or torque control
AC Input 324–528 V AC, three-phase, 50/60 Hz
AC Input Current 6.5 A 13.0 A 28.6 A
Nominal DC Bus Output 530/680 V DC
Continuous Power Output 4/5 kW 8/10 kW 17/22 kW
Peak Power Output 28 kW 136 kW
Efficiency 99% 98%
Continuous DC Output Current 7.36 A 14.73 A 33.8 A
Peak DC Output Current 15.0 A 29.46 A 200 A
Series C Capacitance 220 µF 345 µF 660 µF
Inductance 1000 µH 750 µH 500 µH
Internal Shunt 200 W continuous; 40 kW peak None; external shunt required
System Interface SCANport; analog reference and encoder-related connections

System Integration

Allen-Bradley 1394C-SJT05-A and 1394C-SJT10-A Series C connector locations
Allen-Bradley 1394C-SJT22-A 22 kW system module terminal block
01

System-module connection map

1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A sit at the power and control head of a 1394 analog-servo system and feed the attached axis-module chain.

02

Analog motion reference

The -A system accepts a traditional ±10 V DC command for velocity or torque control rather than a SERCOS fiber-ring command.

03

Shared DC-bus supply

The system module converts the three-phase line input into the 530/680 V DC bus distributed to the axis modules.

04

Axis and logic coordination

Logic power, analog references, encoder-related signals, axis-module power, and motor wiring remain separate while the system module coordinates faults and enable behavior.

Diagnostics and Protection

Protective hardware for 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A changes with the system power class and must be matched to the connected axis capacitance and regenerative load.
01

Model-specific input current

The input and branch-protection calculation must use 6.5 A, 13.0 A, or 28.6 A for the installed SJT05, SJT10, or SJT22 module.

02

Shunt boundary

Series C SJT05 and SJT10 include an internal 200 W continuous shunt; SJT22 has no internal shunt and uses the specified external shunt module.

03

Status and fault monitoring

System and axis status LEDs, current monitoring, thermal-overload detection, and feedback-signal monitoring provide separate diagnostic evidence during commissioning.

Frequently Asked Questions

Are these three -A catalog numbers SERCOS system modules across the 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A model group?

No. The -A suffix identifies the 1394 analog-servo system with a traditional ±10 V DC reference for velocity or torque control. The SERCOS system-module suffix is -D, so the interface letter must not be omitted from identification. This requirement covers 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A.

For users of 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A, how do I choose among SJT05-A, SJT10-A, and SJT22-A?

For equipment identified as 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A, calculate the total continuous and peak demand of the connected axis modules and motors, then select the system module whose DC-bus power and current limits cover that combination. The three choices provide 4/5, 8/10, and 17/22 kW continuous output.

Why does the 22 kW system need a different regeneration plan when the catalog group is 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A?

1394C-SJT22-A has no internal shunt resistor, while the Series C 5 kW and 10 kW system modules include a 200 W continuous internal shunt. The 22 kW installation therefore uses the specified external shunt module and associated fan/power wiring. The models covered are 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A.

Regarding 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A, how should the total axis demand be checked against the selected system-module rating?

Regarding 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A, add the continuous and peak demand of the installed axis modules and compare that total with the selected 4/5 kW, 8/10 kW, or 17/22 kW system-module boundary. The calculation must also include the applicable DC-bus current, capacitance, and regenerative arrangement rather than relying on the number of connected axes.

Can the ±10 V reference be wired with the motor-power conductors for 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A?

No. The analog reference and encoder-related signals are low-level circuits and should be routed and shielded separately from AC input, DC bus, shunt, and motor-output conductors to prevent electrical noise from entering the command path. This distinction applies to 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A.

Within 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A, what should be recorded before replacing only the system module?

Within 1394C-SJT05-A / 1394C-SJT10-A / 1394C-SJT22-A, record the complete -A catalog number, Series C designation, connected axis modules, total bus load, input voltage, shunt arrangement, logic-power source, analog command mode, and stored parameters. Matching only the 1394 family name is insufficient.

Customer Support

www.mvme.cn

One accountable contact throughout the enquiry

Moore Automation keeps product clarification, quotation updates, order communication and shipment information with one contact so customers can follow the same request through each stage.

Enquiry responseCustomer messages receive a response within 12 hours.
Quotation updatesCommercial changes remain attached to the request.
Order follow-upConfirmed information stays with the responsible contact.
Shipment updatesDispatch and tracking details are communicated.

Contact Us

Send the complete model, quantity and destination for a precise quotation.

ContactLeonia
Frequently Asked Questions

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.