Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>AB>Allen-Bradley 1775-MED PLC-3 128K Memory Module
Allen-Bradley 1775-MED PLC-3 128K Memory Module

Allen-Bradley 1775-MED PLC-3 128K Memory Module Item NO.: 2909179

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 1775-MED PLC-3 128K Memory Module
Item NO. 2909179
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-09-17

Allen-Bradley 1775-MED PLC-3 128K Memory Module
CATALOG1775MED

Allen-Bradley · PLC-3 Memory

Allen-Bradley 1775-MED PLC-3 128K Memory Module

128K-word PLC-3 memory for the largest listed standard application capacity in this module group.

Product identity and system role

Product Overview

At 128K words, the 1775-MED supplies 131,072 words for large PLC-3 application and data-table requirements.

The expanded capacity of 1775-MED supports complex program structures, but scan performance and I/O behavior still depend on the processor, logic workload and complete system configuration.

A maintenance replacement must preserve the saved memory image and match the PLC-3 processor chassis, because capacity alone does not establish hardware or revision compatibility.

Concise verified values

Technical Data

Technical Item 1775-MED
Brand Allen-Bradley
Product Type PLC-3 Memory Module
Brand Country United States
Controller Family PLC-3
Memory Capacity 128K words
Exact Word Count 131,072 words
Compatible Chassis Family 1775-A1 / 1775-A2 / 1775-A3
Smaller Family Options 1775-ME4 / 1775-ME8 / 1775-MEA
System Requirement Compatible PLC-3 processor configuration
Large application image

128K Memory Capacity

Functional focus

Program scale

The 131,072-word resource accommodates a larger combined logic and data requirement than ME4, ME8 or MEA.

System relationship

Data organization

Structured tables and I/O images still share the module with executable instructions.

Maintenance check

Performance review

A larger stored program should be evaluated for scan and process-response effects on the installed processor.

Map the memory deliberately

Large-System Data Organization

More capacity needs stronger control.Document table boundaries, message areas and reserved regions so a large PLC-3 application remains understandable and recoverable.

For 1775-MED, large-system data organization must be reviewed with the installed controller hardware and saved application rather than treated as an isolated catalog-number change.

  • Keep a verified offline copy of the complete image.
  • Record capacity use and free-word margin.
  • Validate memory, I/O and communications after restoration.
Selection, replacement and commissioning

Practical Questions

How many words are available in 1775-MED?

The module is rated at 128K, equal to 131,072 words. The controller uses that capacity for both program and data storage.

Does installing 1775-MED automatically improve PLC-3 scan speed?

No; it increases memory capacity rather than processor execution speed. A larger program can increase scan time, so timing should be reviewed after application growth.

What backup practice is appropriate for 1775-MED?

Maintain a verified copy of the complete application and document the data-table layout and free-memory margin. Large legacy applications are difficult to reconstruct from partial records.

Can 1775-MED replace 1775-MEA without system checks?

The larger 128K capacity does not by itself prove compatibility. Confirm the processor, chassis, revision and restored addressing before approving the change.

Why should data-table boundaries be reviewed on 1775-MED?

Large capacity can encourage scattered allocations that are hard to maintain. A documented map reduces addressing mistakes and helps future engineers understand how the controller uses memory.

What proves a 1775-MED replacement is ready for production?

The processor must recognize the full memory image without diagnostics, and I/O, communications and timing-sensitive logic must pass controlled tests. Only then should automatic process control be restored.

Moore Automation

Quotation Accuracy

Moore Automation

Complete product codes lead to better matches

Moore Automation uses the full requested identity to distinguish capacity, revision and system-role differences across legacy automation products. Shortened numbers are not treated as sufficient when several variants share a family prefix.

The commercial response is built around the confirmed catalog, quantity and delivery requirement, with questions resolved before order placement.

Full codesSuffixes are not dropped.
Variant separationClose items kept distinct.
Quantity checkOrder scope confirmed.
Responsive reviewQuestions resolved early.

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.