Target displacement
The probe responds to changes in the gap between its tip and the metallic target.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05 TQ402 standard-mount proximity transducer |
| Item NO. | 2918989 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | VIBRO METER |
| Brand | OTHER PRODUCTS |
| Creation Time | 2026-10-13 |
The Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05 is a standard-mount TQ402 proximity transducer for the TQ402, EA402 and IQS900 proximity measurement system. It senses the relative position of a metallic target and supplies the front-end signal used to derive displacement and vibration measurements.
For TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05, the selected coding specifies the standard environment, M10 × 1 body thread, 72 mm body length, zero unthreaded length, 5 m integral cable, F2 flexible hose with FEP sheath, 50 mm hose length and a 5 m total system length code. These values describe one assembled transducer configuration and should be kept together when selecting the mating installation.
For TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05, the integral coaxial cable terminates in a self-locking miniature coaxial plug. The TQ402 then connects into the EA402 extension and IQS900 conditioner path, where the sensor response is processed into measurement signals for the VM600 or related monitoring system.
| Technical Item | TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05 |
|---|---|
| Brand | Vibro-Meter |
| Product Type | TQ402 standard-mount proximity transducer |
| Measurement Chain | TQ402 / EA402 / IQS900 |
| Body Thread | M10 × 1 |
| Body Length | 72 mm |
| Unthreaded Length | 0 mm |
| Integral Cable | 5 m ±500 mm |
| Cable Protection | Flexible hose with FEP sheath |
| Flexible Hose Length | 50 mm code G050 |
| Total System Length | 5 m code H05 |
| Target | Metallic target |
| Cable Connector | Self-locking miniature coaxial plug |
TQ402 forms the sensing end of the 2 mm-range proximity measurement system.
The probe responds to changes in the gap between its tip and the metallic target.
The integral cable carries the sensor signal to the extension or conditioner without changing the sensor role.
The EA402 and IQS900 complete the chain and provide the processed displacement and vibration output.
The TQ402 ordering codes define how the transducer fits into the mechanical and cable path.
The M10 × 1 thread fixes the transducer at the selected machine location.
F2 and G050 define a short protected section at the cable exit; the remaining cable route still follows the E050 length.
The H05 total-system code is tied to the 5 m configuration and must be considered with any EA402 extension.
Will the available thread and machine clearance accept Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05 at the intended probe point?
Verify the M10 × 1 thread, 72 mm body and 2 mm unthreaded section before installing Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05. The probe position must preserve the required metallic-target gap; cable length cannot compensate for a wrong mounting point.
Can the installed EA402 extension be reused with Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05?
Reuse the EA402 only after checking the connector, calibrated chain length and the 5 m E050 integral cable of Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05. The H05 total-system code must still be met by the complete probe, extension and IQS900 path.
Does the F2/G050 option on Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05 cover every part of the cable route?
F2 and G050 describe the flexible hose protection and its coded length for Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05. Check the unprotected cable exit, bend radius and sealing at both ends; the option does not turn the entire installation into a sealed conduit.
What installation check prevents a false gap signal from Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05?
Confirm the metallic target, probe face and mechanical stand-off before tuning the IQS900 channel for Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05. A wrong target or gap changes the measurement response and should not be corrected by altering the conditioner filter.
How should a noisy output be traced on a Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05 chain?
Inspect the probe seating, coaxial connector, E050 cable and EA402 extension in sequence for Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05. Check the IQS900 input only after the mechanical path and cable shield continuity are confirmed.
Can Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05 be replaced with a TQ902 by keeping the same extension?
No; retain the TQ402 measurement family and complete ordering relationship for Vibro-Meter TQ402 111-402-000-013-A1-B1-C072-D000-E050-F2-G050-H05. TQ402 and TQ902 differ in chain and mechanical selection, so a shared-looking extension does not prove interchangeability.
Moore Automation organizes product enquiries around the complete manufacturer code, requested quantity and the corresponding commercial record. The same identifiers are carried into packing documentation.
Send the complete model and requested quantity with your enquiry.