Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 TQ403 12 mm-range proximity transducer
Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 TQ403 12 mm-range proximity transducer

Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 TQ403 12 mm-range proximity transducer Item NO.: 2918998

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 TQ403 12 mm-range proximity transducer
Item NO. 2918998
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-13

Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 TQ403 12 mm-range proximity transducer
Vibro-MeterTQ403 proximity measurement chainVM600 / VM600Mk2

Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 TQ403 12 mm-range proximity transducer

Product Information

The Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 is a TQ403 proximity transducer for the TQ403, EA403 and IQS900 proximity measurement system. Its 12 mm measurement-range family is used when the probe, extension and conditioner are specified as one calibrated chain.

For TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10, the code selects the standard environment, M20 × 1.5 body thread, 36 mm body length, zero unthreaded length, 1 m integral cable, no optional cable protection, no flexible hose and a 10 m total system length code. The F0/G000 combination leaves the cable without the optional hose or IP172 protection options.

For TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10, the self-locking miniature coaxial connector carries the sensor signal into the EA403/IQS900 path. The total-system length is completed by the integral cable and any EA403 extension selected for the installation.

Technical Data

Technical Item TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10
Brand Vibro-Meter
Product Type TQ403 proximity transducer
Measurement Range Family 12 mm
Body Thread M20 × 1.5
Body Length 36 mm
Unthreaded Length 0 mm
Integral Cable 1 m ±100 mm
Cable Protection None / F0
Flexible Hose None / G000
Total System Length 10 m code H10
Extension Cable EA403
Connector Self-locking miniature coaxial plug

System Integration — EA403 Measurement Chain

TQ403 is the front-end transducer in a chain that continues through EA403 and IQS900.

Transducer position

The M20 × 1.5 body thread fixes the probe at the selected mounting location.

Extension link

The 1 m integral cable can be combined with an EA403 extension to reach the conditioner.

Conditioner handoff

The IQS900 receives the chain signal and supplies the processed analog output to the monitoring system.

Operating Characteristics — 12 mm Probe Limits

The TQ403 code sets the mechanical range and cable boundaries that govern the measurement chain.

12 mm family

The TQ403 family is the 12 mm-range proximity transducer group, distinct from the shorter-range TQ402 family.

Cable route

F0 and G000 specify that no optional hose or flexible-hose section is ordered.

Total length

H10 records a 10 m total system length, so the integral and extension cables must be considered together.

Product Questions

Will the M20 × 1.5 thread and 36 mm body of Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 fit the available machine space?

Check the M20 × 1.5 mounting thread, 36 mm body and target clearance before installing Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. The mechanical reach must be correct before the EA403 cable and IQS900 settings are checked.

How should the EA403 extension be selected around the 1 m cable and H10 arrangement of Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10?

Use the EA403 extension to complete the H10 total-system length for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. Add the 1 m E010 cable and extension together before wiring; do not solve an overlong route by changing only the conditioner.

What protection is required when Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 is ordered with F0 and G000?

F0 and G000 indicate no optional cable protection or flexible hose on Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. Add mechanical support and entry sealing in the installation without recording those site measures as part of the product code.

How should the 12 mm-range target gap be checked before enabling Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10?

Place the probe against the specified metallic target and verify its stand-off before accepting the IQS900 output from Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. A wrong gap changes the transducer response and cannot be corrected by extending the cable.

What should be inspected when the TQ403 chain for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 is noisy?

Inspect the probe thread seating, miniature coaxial connector, E010 cable and EA403 extension in sequence for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. Then check the IQS900 input and the H10 chain length so a wiring fault is not confused with a sensor fault.

Can a TQ402 chain replace Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 when the controller input is the same?

No; retain the TQ403/EA403/IQS900 relationship for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. The shared controller family does not make the different probe range, thread and chain coding interchangeable.

Quality & Warranty

MOORE AUTOMATION
https://www.mvme.cn/

Moore Automation records the complete model and manufacturer before packing so the commercial record remains tied to the requested variant. Eligibility details are kept with the same item record.

Variant record
Manufacturer match
Packing check
Eligibility record
www.mvme.cn

Sales Enquiries

Send the complete model and requested quantity with your enquiry.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.