Transducer position
The M20 × 1.5 body thread fixes the probe at the selected mounting location.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 TQ403 12 mm-range proximity transducer |
| Item NO. | 2918998 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | VIBRO METER |
| Brand | OTHER PRODUCTS |
| Creation Time | 2026-10-13 |
The Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 is a TQ403 proximity transducer for the TQ403, EA403 and IQS900 proximity measurement system. Its 12 mm measurement-range family is used when the probe, extension and conditioner are specified as one calibrated chain.
For TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10, the code selects the standard environment, M20 × 1.5 body thread, 36 mm body length, zero unthreaded length, 1 m integral cable, no optional cable protection, no flexible hose and a 10 m total system length code. The F0/G000 combination leaves the cable without the optional hose or IP172 protection options.
For TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10, the self-locking miniature coaxial connector carries the sensor signal into the EA403/IQS900 path. The total-system length is completed by the integral cable and any EA403 extension selected for the installation.
| Technical Item | TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 |
|---|---|
| Brand | Vibro-Meter |
| Product Type | TQ403 proximity transducer |
| Measurement Range Family | 12 mm |
| Body Thread | M20 × 1.5 |
| Body Length | 36 mm |
| Unthreaded Length | 0 mm |
| Integral Cable | 1 m ±100 mm |
| Cable Protection | None / F0 |
| Flexible Hose | None / G000 |
| Total System Length | 10 m code H10 |
| Extension Cable | EA403 |
| Connector | Self-locking miniature coaxial plug |
TQ403 is the front-end transducer in a chain that continues through EA403 and IQS900.
The M20 × 1.5 body thread fixes the probe at the selected mounting location.
The 1 m integral cable can be combined with an EA403 extension to reach the conditioner.
The IQS900 receives the chain signal and supplies the processed analog output to the monitoring system.
The TQ403 code sets the mechanical range and cable boundaries that govern the measurement chain.
The TQ403 family is the 12 mm-range proximity transducer group, distinct from the shorter-range TQ402 family.
F0 and G000 specify that no optional hose or flexible-hose section is ordered.
H10 records a 10 m total system length, so the integral and extension cables must be considered together.
Will the M20 × 1.5 thread and 36 mm body of Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 fit the available machine space?
Check the M20 × 1.5 mounting thread, 36 mm body and target clearance before installing Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. The mechanical reach must be correct before the EA403 cable and IQS900 settings are checked.
How should the EA403 extension be selected around the 1 m cable and H10 arrangement of Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10?
Use the EA403 extension to complete the H10 total-system length for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. Add the 1 m E010 cable and extension together before wiring; do not solve an overlong route by changing only the conditioner.
What protection is required when Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 is ordered with F0 and G000?
F0 and G000 indicate no optional cable protection or flexible hose on Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. Add mechanical support and entry sealing in the installation without recording those site measures as part of the product code.
How should the 12 mm-range target gap be checked before enabling Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10?
Place the probe against the specified metallic target and verify its stand-off before accepting the IQS900 output from Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. A wrong gap changes the transducer response and cannot be corrected by extending the cable.
What should be inspected when the TQ403 chain for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 is noisy?
Inspect the probe thread seating, miniature coaxial connector, E010 cable and EA403 extension in sequence for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. Then check the IQS900 input and the H10 chain length so a wiring fault is not confused with a sensor fault.
Can a TQ402 chain replace Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10 when the controller input is the same?
No; retain the TQ403/EA403/IQS900 relationship for Vibro-Meter TQ403 111-403-000-013-A1-B1-C036-D000-E010-F0-G000-H10. The shared controller family does not make the different probe range, thread and chain coding interchangeable.
Moore Automation records the complete model and manufacturer before packing so the commercial record remains tied to the requested variant. Eligibility details are kept with the same item record.
Send the complete model and requested quantity with your enquiry.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found