Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter RPS6U 200-582-916-034 / RPS6U 200-582-993-022 | RPS6U rear power-input panels
Meggitt Vibro-Meter RPS6U 200-582-916-034 / RPS6U 200-582-993-022 | RPS6U rear power-input panels

Meggitt Vibro-Meter RPS6U 200-582-916-034 / RPS6U 200-582-993-022 | RPS6U rear power-input panels Item NO.: 2921989

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter RPS6U 200-582-916-034 / RPS6U 200-582-993-022 | RPS6U rear power-input panels
Item NO. 2921989
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-16

Meggitt Vibro-Meter RPS6U 200-582-916-034 / RPS6U 200-582-993-022 | RPS6U rear power-input panels
Meggitt Vibro-Meter · VM600Mk2 / VM600 ABE04x rack power system

Meggitt Vibro-Meter RPS6U 200-582-916-034 / RPS6U 200-582-993-022 | RPS6U rear power-input panels

Terminate two external AC or DC feeds and route them to the rack power-supply positions

01

Product Description

At the rear of an ABE04x rack, Meggitt Vibro-Meter RPS6U 200-582-916-034 / RPS6U 200-582-993-022 are rear power-input panel variants rather than RPS6U converter modules. The 916-034 panel terminates two AC feeds; the 993-022 panel terminates two DC feeds for the corresponding rack supply arrangement.

Two screw-terminal input paths on RPS6U 200-582-916-034 / RPS6U 200-582-993-022 keep the external sources separate on their way to the front RPS6U positions. The AC version adds input fuses and filters and omits front-panel switches, while the DC version provides individual DC inputs for the installed supplies.

Because RPS6U 200-582-916-034 / RPS6U 200-582-993-022 sits at the mains or DC entry boundary, cable type, protective devices and feed separation belong to the panel installation. The panel does not generate the +5 VDC and ±12 VDC rails; conversion occurs in the front RPS6U supply.

RPS6U 200-582-916 AC rear-panel power-path schematic
RPS6U 200-582-916 AC rear-panel power-path schematic
Full-size RPS6U 200-582-916 AC rear-panel power-path schematic×
02

Product Specifications

Brand
Meggitt Vibro-Meter
Product type
RPS6U rear power-input panels
Product family
VM600Mk2 / VM600 ABE04x rack
Complete models
RPS6U 200-582-916-034 / RPS6U 200-582-993-022
Installation position
Rear of ABE04x rack
916-034 input type
Two AC inputs
916-034 termination
Screw terminals
916-034 protection
Input fuses and filters
916-034 switching
No panel switches
993-022 input type
Two DC inputs
993-022 termination
Screw terminals
993-022 feed arrangement
Individual input for each installed supply
Downstream hardware
Front-mounted RPS6U power supplies
Converted rack rails
Generated by RPS6U, not by rear panel
Redundancy boundary
Two independent external feeds when configured
03

Installation Highlights

RPS6U 200-582-916-034 / RPS6U 200-582-993-022 form the cabinet-side input boundary at the rear of an ABE04x rack, so conductor type, external protection and feed separation follow the selected panel.

  1. 01

    916 AC input panel

    RPS6U 200-582-916-034 presents two screw-terminal AC inputs and sends each feed through its own fuse and filter path. The panel has no mains switches, so isolation is provided by the external installation.

  2. 02

    993 DC input panel

    RPS6U 200-582-993-022 presents two screw-terminal DC inputs with an individual input path for each front RPS6U supply. The DC panel does not add AC-style fuse protection, so the installation uses a correctly rated external breaker.

  3. 03

    Rack position and access

    Both RPS6U 200-582-916-034 / RPS6U 200-582-993-022 mount at the rear of the ABE04x rack. Their terminals remain the service boundary between facility wiring and the internal backplane path to the front supplies.

04

System Integration

The rear panel, rack backplane and front RPS6U modules divide the power route into input termination, feed distribution and regulated voltage conversion.

  1. 01

    External source to rear panel

    Facility AC enters RPS6U 200-582-916-034 through two filtered and fused branches, while facility DC enters RPS6U 200-582-993-022 through two separate DC branches. These inputs remain distinct before reaching the rack.

  2. 02

    Rear panel to front supplies

    Each path from RPS6U 200-582-916-034 / RPS6U 200-582-993-022 crosses the backplane connection to the matching front RPS6U position. The rear panel routes input power but does not generate the regulated card supplies.

  3. 03

    Front supplies to card rails

    The front RPS6U modules convert the routed inputs into +5 VDC and ±12 VDC, then return those rails to the rack backplane. This separates a rear-input fault from a converter fault or a downstream rack-card load.

05

Common Questions

Are RPS6U 200-582-916-034 / RPS6U 200-582-993-022 power supplies or rear panels?

RPS6U 200-582-916-034 / RPS6U 200-582-993-022 are rear power-input panels. The front RPS6U modules perform the actual AC/DC-to-backplane conversion.

Which input sources belong to RPS6U 200-582-916-034 / RPS6U 200-582-993-022?

Within RPS6U 200-582-916-034 / RPS6U 200-582-993-022, the 916-034 panel terminates two AC inputs at screw terminals and includes input fuses and filters without panel switches.

How do RPS6U 200-582-916-034 / RPS6U 200-582-993-022 keep two external feeds separate?

Within RPS6U 200-582-916-034 / RPS6U 200-582-993-022, the 993-022 panel keeps two DC feeds on separate screw-terminal paths so each installed front supply can receive its own source.

Why are the fuses on RPS6U 200-582-916-034 / RPS6U 200-582-993-022 not a substitute for rack-card protection?

For RPS6U 200-582-916-034 / RPS6U 200-582-993-022, the 916-034 fuses protect incoming AC paths; rack-card over-voltage, overload and short-circuit behaviour is handled downstream by the converter stages.

Where should voltage conversion be checked when RPS6U 200-582-916-034 / RPS6U 200-582-993-022 has input power?

If input is present at RPS6U 200-582-916-034 / RPS6U 200-582-993-022 but backplane rails are absent, continue the check at the corresponding front RPS6U supply and its high-current connectors.

What must be isolated before working on RPS6U 200-582-916-034 / RPS6U 200-582-993-022?

Isolate both external inputs, not only one feed, before servicing RPS6U 200-582-916-034 / RPS6U 200-582-993-022 in a redundant arrangement.

06

Shipping Services

Moore Automation

Moore Automation can coordinate international shipment details after the requested model and destination are confirmed. Carrier information, tracking updates and order progress are returned through the same account contact.

Nameplate photographs, existing drawings and installed-system details can be kept with the complete requested identifier. This gives technical, commercial and logistics records one consistent product reference.

Shipment continuityDestination and tracking stay with the order
Industrial scopeAutomation and machinery-monitoring hardware
Document continuityModels, drawings and shipment records stay linked
Moore Automation shipping services imagewww.mvme.cn
Full-size Moore Automation image×
08

Enquiry Information

Enquiry Information

Discuss the exact product reference and installed-system requirement with Moore Automation.

ManagerLeonia
Emailsales@mvme.cnWhatsApp+86 180 3017 5807
Moore Automation · RPS6U rear power-input panelsModel reference: RPS6U 200-582-916-034 / RPS6U 200-582-993-022

No related record found