Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ED1052-1HB08-0BA2 | LOGO! 24 V AC/DC Relay Base Module
Siemens 6ED1052-1HB08-0BA2 | LOGO! 24 V AC/DC Relay Base Module

Siemens 6ED1052-1HB08-0BA2 | LOGO! 24 V AC/DC Relay Base Module Item NO.: 2927536

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ED1052-1HB08-0BA2 | LOGO! 24 V AC/DC Relay Base Module
Item NO. 2927536
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-27

Siemens 6ED1052-1HB08-0BA2 LOGO! 24 V AC/DC Relay Base Module
LOGO! 24RCE

Siemens · Industrial Automation

Siemens 6ED1052-1HB08-0BA2 | LOGO! 24 V AC/DC Relay Base Module

Eight digital inputs and four relay outputs in the LOGO! 8.4 platform.

Supply24 V AC/DC
Outputs4 relays
01

Product Introduction

Siemens 6ED1052-1HB08-0BA2 is the LOGO! 24RCE base module for 24 V AC/DC control power. It provides eight digital inputs, four relay outputs, a local display and keys, and the Ethernet connection used by the LOGO! 8.4 engineering and communication functions.

In a machine circuit, Siemens 6ED1052-1HB08-0BA2 reads the eight 24 V field states into the user program and switches externally supplied loads through its four relay contacts. Because the contact side is separate from the input supply, the load voltage, protection and return path must be documented independently.

Expansion and network operation extend Siemens 6ED1052-1HB08-0BA2 beyond its base I/O. The exact expansion order, IP settings, program version and local-display pages belong to the device record and should be retained together during commissioning or replacement.

02

Technical Information

Brand Siemens
Model 6ED1052-1HB08-0BA2
Product Name LOGO! 24RCE
Country Germany
Generation LOGO! 8.4
Supply 24 V AC/DC; 20.4 to 26.4 V AC or 20.4 to 28.8 V DC
Digital Inputs 8
Relay Outputs 4
Program Capacity 400 function blocks
Ethernet Integrated
Local Display / Keys Yes
Programming LOGO! Soft Comfort V8.4 or later
Power Consumption 60 to 185 mA AC; 25 to 100 mA DC
Power Loss 1.4 to 4.4 W AC; 0.6 to 2.4 W DC
RTC Backup / Accuracy Typically 20 days; ±2 s/day
Relay Contact Rating Up to 10 A per relay; 240 V AC/DC rated
Maximum Surge Current 30 A
Module Width 4 spacing units
Dimensions (W × H × D) 71.5 × 90 × 60 mm
Approximate Weight 240 g
03

System Integration

Siemens 6ED1052-1HB08-0BA2 links 24 V field wiring, relay loads, Ethernet and optional LOGO! expansion modules through one configured base module. Treat the controller, its mixed digital or analog inputs, transistor load supply and Ethernet project as four linked layers during integration.

01

Map the base I/O

Assign every Siemens 6ED1052-1HB08-0BA2 terminal to a named field device and keep the relay load supply separate in the drawing. Create a terminal map that identifies which configurable inputs are used as digital, analog or high-speed points, then keep the same assignment in the project tags.

02

Build the expansion chain

Place supported modules in the documented order and verify their power demand before coupling them to Siemens 6ED1052-1HB08-0BA2. Add expansion modules in their physical left-to-right order and reserve the resulting addresses before copying program blocks from another LOGO! station.

03

Connect the network

Set the Siemens 6ED1052-1HB08-0BA2 address and communication role before linking other LOGO! or supervisory devices. Prove the communication route by checking the configured IP partner and online device identity before relying on remote status or downloads.

04

Monitoring and Control

Operate Siemens 6ED1052-1HB08-0BA2 by comparing field state, displayed program state and physical relay-load response at each step. Monitoring should follow the signal from terminal to logic result and finally to the powered load, rather than stopping at the front-panel symbol.

1

Input confirmation

Use the front display and online status to confirm that Siemens 6ED1052-1HB08-0BA2 sees the intended 24 V input. For a questionable input, compare measured voltage, the input indication and the live program value; disagreement between two of these narrows the fault layer.

2

Logic observation

Monitor timers, counters and interlocks in Siemens 6ED1052-1HB08-0BA2 before forcing an output; the absent output may be a valid program result. Use online block status to locate the permissive, latch or timer that prevents an output, then confirm that the logic belongs to the intended physical channel.

3

Load proof

Command the Siemens 6ED1052-1HB08-0BA2 relay and measure the externally supplied load circuit under actual operating conditions. For an active output, measure the field supply and load return under operation and record whether overload protection or wiring, rather than the command bit, interrupted current.

05

Frequently Asked Questions

Why does Siemens 6ED1052-1HB08-0BA2 power up but not read a 24 V input?

Check whether Siemens 6ED1052-1HB08-0BA2 is supplied and referenced for the selected AC or DC circuit, then measure the input against the documented common.

Why is the Siemens 6ED1052-1HB08-0BA2 Ethernet connection unavailable?

Verify link state, IP address, subnet and project interface for Siemens 6ED1052-1HB08-0BA2, then rule out an address conflict before changing hardware.

Can Siemens 6ED1052-1HB08-0BA2 switch a different load voltage than its input supply?

The Siemens 6ED1052-1HB08-0BA2 relay contacts are separately supplied, but the selected load voltage and current must stay within the contact specification and external protection.

Why does Siemens 6ED1052-1HB08-0BA2 lose expected functions after a project download?

Confirm that the project targets Siemens 6ED1052-1HB08-0BA2 and LOGO! 8.4, and verify expansion configuration, network settings and parameter blocks.

How should an intermittent Siemens 6ED1052-1HB08-0BA2 output be isolated?

Compare the Siemens 6ED1052-1HB08-0BA2 output bit, relay indication, contact voltage and load current at the same time; this separates logic, contact and field-load causes.

What data should accompany a Siemens 6ED1052-1HB08-0BA2 enquiry?

Provide the exact Siemens 6ED1052-1HB08-0BA2 article, quantity, program generation, expansion list, supply type, load schedule and destination.

06

Service Support

Moore Automation

https://www.mvme.cn

Moore Automation provides a direct enquiry route for industrial automation article review, available documents and order communication.

The service keeps the requested article and quantity together without promising manufacturer authorization, stock or a fixed completion date.

Article checkExact model and quantity stay visible.
Document handlingAvailable records can be coordinated.
Packing reviewProduct form informs preparation.
Follow-upOne named contact handles questions.

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.