Product Name Siemens 6ED1052-1CC08-0BA2 | LOGO! 24 V DC Transistor Base Module
Item NO. 2927537
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-27

Siemens 6ED1052-1CC08-0BA2 LOGO! 24 V DC Transistor Base Module
LOGO! 24CE

Siemens · Industrial Automation

Siemens 6ED1052-1CC08-0BA2 | LOGO! 24 V DC Transistor Base Module

Fast 24 V DC control with eight inputs and four transistor outputs.

Inputs8 · 4 analog-capable
Outputs4 transistor
01

Model Information

Siemens 6ED1052-1CC08-0BA2 is the LOGO! 24CE base module for 24 V DC systems. Its eight digital inputs include four positions that can be assigned as 0 to 10 V analog inputs, while four transistor outputs switch DC loads without relay contacts.

The signal path through Siemens 6ED1052-1CC08-0BA2 depends on input assignment. A mixed-use input wired for analog measurement needs the documented M reference and an analog function in the program; a transistor output needs the correct 24 V load supply, polarity and return.

As a LOGO! 8.4 device, Siemens 6ED1052-1CC08-0BA2 combines its local display with Ethernet, data and web-related functions supported by the configured project. The exact article remains important because relay-output LOGO! modules do not reproduce the same DC switching behavior.

02

Technical Specifications

Brand Siemens
Model 6ED1052-1CC08-0BA2
Product Name LOGO! 24CE
Country Germany
Generation LOGO! 8.4
Supply 24 V DC; permitted 20.4 to 28.8 V DC
Digital Inputs 8; four can serve as 0–10 V AI
Transistor Outputs 4
Program Capacity 400 function blocks
Ethernet Integrated
Local Display / Keys Yes
Programming LOGO! Soft Comfort V8.4 or later
No-Load / Full-Load Current 25 to 50 mA no-load; up to 1.2 A at full output load
Power Loss 0.6 to 1.2 W
High-Speed Inputs I3 to I6; up to 5 kHz
Analog Input Characteristics I1, I2, I7, I8; 0 to 10 V; 80 kΩ; ±1.5% full scale
Transistor Output Behavior 0.3 A per channel; short-circuit and overload protected
Module Width 4 spacing units
Dimensions (W × H × D) 71.5 × 90 × 60 mm
Approximate Weight 195 g
03

Product Functions

Siemens 6ED1052-1CC08-0BA2 acquires binary or selected analog values, executes the LOGO! program and drives four DC transistor outputs. The base module combines discrete control, configurable voltage inputs and protected transistor outputs, so the project must define the role of each terminal before commissioning.

01

Mixed-use acquisition

Configure the intended Siemens 6ED1052-1CC08-0BA2 input as digital or 0 to 10 V analog before scaling it in the program. Assign every configurable input to one documented function and use scaling and limits that match the connected sensor instead of treating an analog value as a generic percentage.

02

Program execution

Timers, counters, logic blocks and network values in Siemens 6ED1052-1CC08-0BA2 determine the output command rather than direct input-to-output wiring. Build the control sequence so input validation, permissives and output commands can be observed independently during a stopped-machine test.

03

DC output switching

The four Siemens 6ED1052-1CC08-0BA2 transistor channels switch correctly only with the documented polarity, load supply and return. When a load does not operate, trace the commanded output through its field supply, common return and protection path before changing program logic.

04

Performance Characteristics

Siemens 6ED1052-1CC08-0BA2 response is shaped by input mode, program cycle and the electrical behavior of its transistor load path. Performance checks should test timing, analog stability and switching behavior in the actual program path without turning the module table into a second specification list.

1

Analog stability

Route low-level analog wiring for Siemens 6ED1052-1CC08-0BA2 away from switching conductors and use one stable reference potential. Apply known input transitions and compare online timing with the programmed filter or counting function so short pulses are not misdiagnosed as wiring faults.

2

Cycle-dependent logic

Check the Siemens 6ED1052-1CC08-0BA2 program cycle and block timing when a fast input event does not produce the expected output duration. For analog channels, use a known reference signal and compare raw value, scaled value and process display while checking shielding and the common reference.

3

Output loading

Evaluate steady current and switching frequency for each Siemens 6ED1052-1CC08-0BA2 transistor load; do not apply relay contact assumptions. Cycle each transistor load at the intended operating rate and observe temperature, supply dip and protection response under the real load rather than an unloaded indicator test.

05

Common Product Questions

Why is a 0 to 10 V value wrong on Siemens 6ED1052-1CC08-0BA2?

Confirm the selected analog-capable input, M reference and scaling block for Siemens 6ED1052-1CC08-0BA2, then measure the voltage at the terminal.

Why does a Siemens 6ED1052-1CC08-0BA2 output LED turn on without load current?

Check the Siemens 6ED1052-1CC08-0BA2 load supply, polarity, return and field fuse; the logic command does not complete an open external circuit.

Can Siemens 6ED1052-1CC08-0BA2 replace a relay-output LOGO! module?

Not by output count alone. Siemens 6ED1052-1CC08-0BA2 has 24 V DC transistor outputs, so voltage, polarity and load behavior must match the application.

What causes noisy thresholds in Siemens 6ED1052-1CC08-0BA2?

Inspect analog reference, shielding, routing and programmed hysteresis for Siemens 6ED1052-1CC08-0BA2 before increasing software filtering.

Why does Siemens 6ED1052-1CC08-0BA2 miss a brief input change?

Compare the pulse width with Siemens 6ED1052-1CC08-0BA2 input behavior and program cycle, then use the suitable counting or edge logic where documented.

What should be documented before replacing Siemens 6ED1052-1CC08-0BA2?

Save the exact Siemens 6ED1052-1CC08-0BA2 article, project, IP settings, input modes, analog scaling, output loads and expansion order.

06

Our Advantages

Moore Automation

https://www.mvme.cn

Moore Automation keeps complete article references, requested quantities and available technical files in one industrial automation enquiry route.

This organization supports clear follow-up without representing manufacturer authorization, guaranteed stock, fixed delivery or guaranteed technical resolution.

Exact referencesFull article strings remain visible.
Technical coordinationAvailable files can follow the request.
Multi-brand handlingSeveral automation categories can be reviewed.
Direct routeA named contact manages follow-up.

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.