Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter CA202 144-202-000-106 / CA202 144-202-000-206 | CA202 piezoelectric accelerometers with 3 m integral cables
Meggitt Vibro-Meter CA202 144-202-000-106 / CA202 144-202-000-206 | CA202 piezoelectric accelerometers with 3 m integral cables

Meggitt Vibro-Meter CA202 144-202-000-106 / CA202 144-202-000-206 | CA202 piezoelectric accelerometers with 3 m integral cables Item NO.: 2921990

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter CA202 144-202-000-106 / CA202 144-202-000-206 | CA202 piezoelectric accelerometers with 3 m integral cables
Item NO. 2921990
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-16

Meggitt Vibro-Meter CA202 144-202-000-106 / CA202 144-202-000-206 | CA202 piezoelectric accelerometers with 3 m integral cables
Meggitt Vibro-Meter · CA202 high-temperature charge-output accelerometers

Meggitt Vibro-Meter CA202 144-202-000-106 / CA202 144-202-000-206 | CA202 piezoelectric accelerometers with 3 m integral cables

Convert machine acceleration into a differential charge signal for external conditioning

01

Product Information

Meggitt Vibro-Meter CA202 144-202-000-106 / CA202 144-202-000-206 are CA202 piezoelectric accelerometers with 3 m integral cables. The 106 code is the Ex version and the 206 code is the standard version; both generate a differential charge signal for an external charge conditioner.

A symmetrical shear-mode element inside CA202 144-202-000-106 / CA202 144-202-000-206 converts acceleration into charge at 100 pC/g. The integral low-noise cable carries that charge away from the hot sensor location, while the stainless-steel hose provides mechanical protection along the route.

Four M6 fasteners establish the mechanical coupling for CA202 144-202-000-106 / CA202 144-202-000-206. Mounting surface, tightening torque and cable strain affect the path from machine vibration to the charge amplifier, so the sensor body and cable route are treated as one installed assembly.

CA202 mechanical and cable drawing
CA202 mechanical and cable drawing
Full-size CA202 mechanical and cable drawing×
02

Technical Data

Brand
Meggitt Vibro-Meter
Product type
CA202 piezoelectric accelerometers
Product family
CA202
Complete models
CA202 144-202-000-106 / CA202 144-202-000-206
106 designation
Ex version, 3 m integral cable
206 designation
Standard version, 3 m integral cable
Measurement element
Symmetrical shear-mode piezoelectric
Signal transmission
Differential charge output
Sensitivity
100 pC/g ±5%
External processing
Charge conditioner / monitoring electronics
Integral cable
Low-noise cable in stainless-steel hose
Cable length
3 m
Resonant frequency
Greater than 22 kHz nominal
Insulation resistance
At least 10^9 ohm
Mounting
Four M6 screws
Fastening torque
15 N·m
Sensor mass
Approx. 250 g
Cable mass
Approx. 135 g/m
Input power
None at sensor
03

Product Functions

CA202 144-202-000-106 / CA202 144-202-000-206 perform the sensing stage of a charge-based vibration channel, converting machine acceleration into a differential charge signal for external conditioning electronics.

  1. 01

    Shear-mode conversion

    Machine acceleration loads the symmetrical shear-mode element in CA202 144-202-000-106 / CA202 144-202-000-206. The element produces a nominal 100 pC of differential charge for each g of acceleration.

  2. 02

    Passive sensor output

    CA202 144-202-000-106 / CA202 144-202-000-206 require no electrical supply at the sensor head. Their low-noise integral cable carries the charge directly to the external IPC70x or other specified charge-conditioning input.

  3. 03

    Hot-zone signal path

    The sensor body remains at the machine measurement point while the integral cable moves the small charge signal away from the hot zone. The flexible stainless-steel hose protects that cable without changing the sensing function.

04

Installation Highlights

Mechanical coupling, integral-cable routing and version selection determine how CA202 144-202-000-106 / CA202 144-202-000-206 transfer machine motion to the charge conditioner.

  1. 01

    Four-point mounting

    Four M6 fasteners clamp CA202 144-202-000-106 / CA202 144-202-000-206 to the prepared surface. Tightening the fasteners to 15 N·m establishes the mechanical path used by the shear element.

  2. 02

    Integral lead routing

    The three-metre low-noise cable is part of CA202 144-202-000-106 / CA202 144-202-000-206 and cannot be treated as a detachable field lead. Its protective hose is routed without pulling, twisting or transferring strain into the sensor body.

  3. 03

    Environmental version

    CA202 144-202-000-106 is the Ex version and CA202 144-202-000-206 is the standard version. The installed sensor, cable route and external conditioner therefore follow the environment represented by the complete ordering number.

05

Product Questions

Which version is hazardous-area rated in CA202 144-202-000-106 / CA202 144-202-000-206?

In CA202 144-202-000-106 / CA202 144-202-000-206, the 106 item is the Ex version with a 3 m integral cable and the 206 item is the standard 3 m version.

Why does CA202 144-202-000-106 / CA202 144-202-000-206 need a charge conditioner?

CA202 144-202-000-106 / CA202 144-202-000-206 produces a differential charge signal, so it connects to a charge conditioner rather than a powered voltage-input channel.

What mounting hardware establishes the CA202 144-202-000-106 / CA202 144-202-000-206 measurement path?

Four M6 fasteners tightened to the specified 15 N·m establish the mechanical path from the machine surface into CA202 144-202-000-106 / CA202 144-202-000-206.

How should the integral cable of CA202 144-202-000-106 / CA202 144-202-000-206 be treated?

The 3 m low-noise lead and stainless-steel hose are integral parts of CA202 144-202-000-106 / CA202 144-202-000-206 and are routed without pulling or twisting the sensor body.

What does 100 pC/g mean for CA202 144-202-000-106 / CA202 144-202-000-206?

For CA202 144-202-000-106 / CA202 144-202-000-206, a 100 pC/g sensitivity means each g of acceleration produces 100 pC of charge before the external conditioner converts it to the monitoring signal.

Which checks help separate a mounting problem from a CA202 144-202-000-106 / CA202 144-202-000-206 sensor problem?

Check the mounting surface and fasteners first, then the integral cable and conditioner input. This separates poor mechanical coupling from a CA202 144-202-000-106 / CA202 144-202-000-206 signal-path fault.

06

Quality & Warranty

Moore Automation

Moore Automation records the supplied product identity and customer request before commercial processing. Clear records help keep the quoted model, supplied item and supporting order documents aligned.

Nameplate photographs, existing drawings and installed-system details can be kept with the complete requested identifier. This gives technical, commercial and logistics records one consistent product reference.

Record controlRequested and supplied identities remain connected
Industrial scopeAutomation and machinery-monitoring hardware
Document continuityModels, drawings and shipment records stay linked
Moore Automation quality & warranty imagewww.mvme.cn
Full-size Moore Automation image×
08

Sales Enquiries

Sales Enquiries

Discuss the exact product reference and installed-system requirement with Moore Automation.

ManagerLeonia
Emailsales@mvme.cnWhatsApp+86 180 3017 5807
Moore Automation · CA202 piezoelectric accelerometers with 3 m integral cablesModel reference: CA202 144-202-000-106 / CA202 144-202-000-206

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.