Command conditioning
MOD circuitry scales the incoming set-point before the current loop applies it to the power stage.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bosch Rexroth TDM1.2-100-300-W1-115 / TDM1.2-100-300-W1-220 100 A AC Servo Drive Controllers |
| Item NO. | 2944600 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BOSCH |
| Brand | BOSCH |
| Creation Time | 2026-11-24 |
TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220 are 100 A TDM 1.2 AC servo drive controllers supplied from a 300 V DC link. Their forced-ventilated power sections provide a 100 A peak-current class and a 65 A continuous-current boundary within a modular drive system.
The 115 and 220 endings keep the blower-supply identities of TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220 separate. Both share the W1 cooling form and 100 A controller frame, but the auxiliary fan circuit must follow the voltage marked on the exact unit.
TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220 use an installed MOD programming module to match the controller to the servo motor and define command and actual-value scaling. The module board, motor feedback and current-processing paths work together while remaining electrically separate from the DC link and motor output.
| Specification | TDM1.2-100-300-W1-115 | TDM1.2-100-300-W1-220 |
|---|---|---|
| Brand | Bosch Rexroth | Bosch Rexroth |
| Product family | TDM 1.2 | TDM 1.2 |
| Product type | AC servo drive controller | AC servo drive controller |
| Current class | 100 A | 100 A |
| Peak current | 100 A | 100 A |
| Continuous current | 65 A | 65 A |
| DC-link voltage | 300 V ±15% | 300 V ±15% |
| Cooling | Forced ventilation | Forced ventilation |
| Fan-supply record | 115 V AC | 220 V AC |
| Fan frequency | 50–60 Hz | 50–60 Hz |
| Type power | 30 kW | 30 kW |
| Power loss at continuous current | 400 W | 400 W |
| Signal-processing +24 V load | 1.45 A | 1.45 A |
| Mass | 10.5 kg | 10.5 kg |
| Protection | IP10 | IP10 |
The 100 A power stage follows a command shaped by the programming module and returns an actual-current value to the controller.
MOD circuitry scales the incoming set-point before the current loop applies it to the power stage.
The output section operates inside the 100 A peak and 65 A continuous-current envelope.
The current feedback signal closes the inner torque loop and supports stable motor behavior across the operating range.
Motor matching is distributed across physical feedback wiring and the removable MOD hardware record.
Motor position and condition signals return through dedicated low-voltage terminals outside the motor-power path.
Component positions on the MOD board establish the documented scaling and controller/motor combination.
The 115 or 220 field belongs to the forced-ventilation supply and must remain with the same configuration record.
When checking TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220, confirm forced ventilation and a clear path for the 400 W continuous-current dissipation.
On TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220, inspect the feedback cable, connector, motor identity and programming-module pairing as one chain.
On TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220, read the final 115 or 220 suffix and blower plate rather than using the shared 100 A frame.
To keep TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220 unambiguous, compare command scaling, MOD settings, actual-current signal and the 65 A continuous boundary.
For TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220, photograph the MOD rating plate and board identity before moving the unit or disconnecting the module.
For a site record covering TDM1.2-100-300-W1-115 and TDM1.2-100-300-W1-220, recognize that the 115 and 220 suffixes change the fan supply while the 100 A peak, 65 A continuous and 300 V DC-link power stage remains the same.
Moore Automation coordinates industrial product enquiries that depend on complete controller and plug-in module identities.
For these 100 A TDM records, the fan-voltage suffix, MOD details, requested documentation and packing information can remain attached to the correct model through shipment follow-up.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found