The HDS05.2-W300N frame sets the 300 A rated and peak-current class of HDS05.2-W300N-HS32-01-FW.
Rexroth
Indramat
DIAX04 · 300 A POWER STAGE
Bosch Rexroth HDS05.2-W300N-HS32-01-FW DIAX04 HDS SERCOS Drive Controller
Model Overview
SERCOS · HS32Bosch Rexroth Indramat HDS05.2-W300N-HS32-01-FW is a second-generation DIAX04 HDS drive controller whose HDS05.2-W300N basic unit provides a 300 A rated power stage. The HS32-01-FW configuration adds SERCOS command communication and an HSM software module to the air-cooled basic unit.
The internal signal chain of HDS05.2-W300N-HS32-01-FW connects the SERCOS command module, HSM parameter store, optional plug-in positions and motor feedback to the drive controller. The optical command path carries setpoints and status, while X4 returns the motor measuring-system signals and X3 carries local control and diagnostic signals.
The larger frame of HDS05.2-W300N-HS32-01-FW supplies 175 A continuous current at 4 kHz or 100 A at 8 kHz and has 1200 W power loss at the published continuous point. Its built-in blower uses control-cabinet air, making the 25 kg unit and its thermal load part of the cabinet mechanical and cooling plan.
Technical Details
15 verified rows| Brand | Bosch Rexroth Indramat |
|---|---|
| Product name | DIAX04 HDS SERCOS drive controller |
| Basic unit | HDS05.2-W300N |
| Configuration | HS32-01-FW |
| Command communication | SERCOS interface |
| Cooling | Internal air, built-in blower |
| Rated / peak current | 300 A / 300 A |
| Continuous current at 4 / 8 kHz | 175 A / 100 A |
| Power loss at continuous current | 1200 W |
| Basic-unit weight | 25 kg |
| Signal-processing consumption | 55 W from ±26 V source |
| Serial service interface | RS232 / RS485 at X2 |
| Motor feedback / motor output | X4 / X5 |
| Rated ambient boundary | +5…+45 °C; up to 1000 m |
| Protection / mounting | IP10 / closed cabinet |
Power and Thermal Management: A 300 A Cabinet Load
Heat flowAt 4 kHz, HDS05.2-W300N-HS32-01-FW carries the higher 175 A continuous-current boundary. At 8 kHz, that boundary becomes 100 A, so switching frequency, motor load and heat generation have to be treated together.
The published 1200 W loss for HDS05.2-W300N-HS32-01-FW enters the cabinet heat balance alongside supply-unit and neighboring-drive losses. The built-in blower moves internal cabinet air rather than separating the heat into an external cooling circuit.
Internal air cooling links inlet clearance, outlet clearance and cabinet heat removal to the same installation plan.
The 1200 W published loss belongs to the exact HDS05.2 continuous-current condition, not to every operating point.
Diagnostics and Protection: Signals Around the Power Stage
Control boundariesThe control electronics monitor command, feedback and motor conditions without mixing those low-level paths with the 300 A motor-power output.
H1 reports local drive conditions
Warnings and errors for HDS05.2-W300N-HS32-01-FW appear on the local display, with S1 assigned to fault reset.
X4 closes the measuring loop
Motor feedback reaches HDS05.2-W300N-HS32-01-FW at X4, while motor temperature and brake circuits remain on X6.
SERCOS carries cyclic control data
The optical transmitter and receiver connect the HS32 SERCOS configuration to the machine-control ring; X2 remains the separate service interface.
Customer Questions
06 practical checks01A label shows W300 on HDS05.2-W300N-HS32-01-FW. Can 300 A be used as its continuous-current value?
No. The W300 field identifies the rated and peak-current frame of HDS05.2-W300N-HS32-01-FW; continuous current remains 175 A at 4 kHz or 100 A at 8 kHz.
02The HDS05.2-W300N-HS32-01-FW cabinet runs hot after nearby hardware is installed. What should be checked first?
Inspect the blower inlet and outlet around HDS05.2-W300N-HS32-01-FW and confirm that adjacent wiring or devices do not block internal cabinet airflow through the 300 A frame.
03After motor work on HDS05.2-W300N-HS32-01-FW, which front connections must remain separated?
Keep X4 motor feedback, X5 motor power, and X6 temperature-monitor and holding-brake circuits separate on HDS05.2-W300N-HS32-01-FW; each connector serves a different part of the closed-loop drive.
04If the machine control cannot exchange cyclic data with HDS05.2-W300N-HS32-01-FW, should X2 be treated as the SERCOS port?
No. HDS05.2-W300N-HS32-01-FW uses the HS32 optical transmitter and receiver for SERCOS; X2 is the separate RS232/RS485 programming and diagnostic interface.
05How is the thermal contribution of HDS05.2-W300N-HS32-01-FW added without double counting?
Assign the published 1200 W continuous-point loss once to HDS05.2-W300N-HS32-01-FW, then add the independent supply-unit and neighboring-drive losses to the cabinet balance.
06What evidence should be recorded before HDS05.2-W300N-HS32-01-FW is removed from service?
Record the complete HDS05.2-W300N-HS32-01-FW designation, configuration plate, HS32 module, HSM software-module entry and connector layout so the 300 A basic unit is not separated from its installed configuration.