SERCOS connects HDS04.2-W200N-HS32-01-FW to the machine control through optical transmit and receive paths.
Rexroth
Indramat
DIAX04 · 200 A POWER STAGE
Bosch Rexroth HDS04.2-W200N-HS32-01-FW DIAX04 HDS SERCOS Drive Controller
Product Summary
SERCOS · HS32Bosch Rexroth Indramat HDS04.2-W200N-HS32-01-FW is a second-generation DIAX04 HDS drive controller with a 200 A rated power stage, internal air cooling and SERCOS command communication. The configured unit combines the HDS04.2-W200N basic unit, the SERCOS command module, an HSM software module and the plug-in modules recorded by the configuration type plate.
The power and signal routes of HDS04.2-W200N-HS32-01-FW meet at the drive control electronics but remain physically divided. The integrated bus at X1 brings control power from the neighboring supply unit, L+ and L− carry the shared DC bus, X5 sends three-phase power to the motor, and X4 receives the motor-feedback signals used by the control loop.
At the published continuous point, HDS04.2-W200N-HS32-01-FW provides 120 A at 4 kHz or 80 A at 8 kHz and produces 800 W of power loss. These values apply with rated ambient conditions of +5…+45 °C and installation elevation up to 1000 m; the IP10 enclosure requires installation in a closed cabinet.
Specification Details
15 verified rows| Brand | Bosch Rexroth Indramat |
|---|---|
| Product name | DIAX04 HDS SERCOS drive controller |
| Basic unit | HDS04.2-W200N |
| Configuration | HS32-01-FW |
| Command communication | SERCOS interface |
| Cooling | Internal air, built-in blower |
| Rated / peak current | 200 A / 200 A |
| Continuous current at 4 / 8 kHz | 120 A / 80 A |
| Power loss at continuous current | 800 W |
| Basic-unit weight | 19 kg |
| Signal-processing consumption | 30 W from ±26 V source |
| Serial service interface | RS232 / RS485 at X2 |
| Motor feedback / motor output | X4 / X5 |
| Rated ambient boundary | +5…+45 °C; up to 1000 m |
| Protection / mounting | IP10 / closed cabinet |
Monitoring and Control: Commands, Feedback and Status
Closed-loop operationThe SERCOS module in HDS04.2-W200N-HS32-01-FW receives cyclic commands from the control and returns drive status. X4 supplies the separate motor-feedback path that lets the drive compare actual motion with those commands.
Local information remains available independently of the optical command bus. HDS04.2-W200N-HS32-01-FW uses H1 for warnings and errors, S1 for fault reset, and X2 for RS232/RS485 parameterization and diagnosis.
X4 returns the motor measuring-system signals, while X6 carries temperature monitoring and brake circuits.
The HSM software module holds firmware and parameter data so those records remain distinct from the 200 A basic unit.
Installation Highlights: Shared Bus and Thermal Load
Cabinet planningThe 200 A frame affects both electrical distribution and heat removal, so the neighboring bus connections and cabinet airflow must be planned as one physical arrangement.
Supply continues from the neighboring unit
X1 carries the integrated control bus and L+/L− carry DC-bus power into HDS04.2-W200N-HS32-01-FW and onward to adjacent drive units.
Continuous load becomes cabinet loss
At the published continuous-current point, HDS04.2-W200N-HS32-01-FW contributes 800 W of drive-controller loss to the thermal calculation.
Internal cooling needs a clear route
The built-in blower moves cabinet air through the controller, so inlet and outlet regions must remain clear within the closed enclosure.
Questions & Answers
06 practical checks01HDS04.2-W200N-HS32-01-FW is being added to an existing DIAX04 row. Which links continue power through the cabinet?
On HDS04.2-W200N-HS32-01-FW, X1 continues the integrated control bus while L+/L- carry DC-bus energy. These links must not be confused with the X5 motor output.
02A motor reports no position after reconnecting HDS04.2-W200N-HS32-01-FW. Which connector should be checked before the power terminals?
Check the motor measuring-system connection at X4 on HDS04.2-W200N-HS32-01-FW. X5 is motor power, while X6 is reserved for temperature monitoring and holding-brake circuits.
03Can the optical command loop replace the service cable during diagnosis of HDS04.2-W200N-HS32-01-FW?
No. HDS04.2-W200N-HS32-01-FW uses SERCOS for cyclic commands and status, but X2 remains the separate RS232/RS485 route for parameterization and diagnostic access.
04Before sizing cabinet cooling for HDS04.2-W200N-HS32-01-FW, which drive loss belongs in the calculation?
Use the 800 W published loss for HDS04.2-W200N-HS32-01-FW at its stated continuous-current point, then add the losses of the supply unit and neighboring cabinet devices once.
05Why is an open mounting panel unsuitable for HDS04.2-W200N-HS32-01-FW?
HDS04.2-W200N-HS32-01-FW is an IP10, internal-air-cooled unit. A closed control cabinet provides the protection boundary and keeps the blower inlet and outlet within the planned air route.
06Which records should travel with HDS04.2-W200N-HS32-01-FW when its software module is removed?
Keep the HDS04.2-W200N-HS32-01-FW full designation, HSM software-module code, firmware entry and parameter backup together; the W200N basic-unit code alone does not identify the configured drive.
Service Support
Moore AutomationMoore Automation Limited
https://www.mvme.cn/Moore Automation Limited coordinates component enquiries through one named account contact. Complete model strings, quantities and requested documentation are recorded together so the commercial response remains tied to the exact product.
Shipment updates and document requests can be coordinated on the same enquiry without rewriting the manufacturer code.






No related record found