300 V DC input
The modular DC link feeds the servo power section through the busbars and bus connector.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bosch Rexroth TDM4.1-030-300-W1 30 A Forced-Ventilation Servo Drive Controller |
| Item NO. | 2944601 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BOSCH |
| Brand | BOSCH |
| Creation Time | 2026-11-24 |
TDM4.1-030-300-W1 is a forced-ventilation AC servo drive controller for a 300 V DC modular drive bus. The power section provides 30 A type and peak current, 25 A continuous current and 9 kW type power for the connected servo motor.
The W1 cooling field in TDM4.1-030-300-W1 requires an LE5 fan unit. Depending on the fan version, the auxiliary supply can be 24 V DC, 115 V AC or 220 V AC, while the controller remains the same 30 A forced-ventilation frame.
TDM4.1-030-300-W1 combines busbar and bus-connection hardware, a MOD programming module, plug-in signal terminals and a three-phase motor output on the front of the modular unit. Power and feedback paths remain separated while the fan moves air through the assigned cooling route.
| Specification | TDM4.1-030-300-W1 |
|---|---|
| Brand | Bosch Rexroth |
| Product family | TDM 4.1 |
| Product type | AC servo drive controller |
| Cooling | Forced ventilation; fan unit required |
| Type current | 30 A |
| Peak current | 30 A |
| Continuous current | 25 A |
| DC-link voltage | 300 V ±15% |
| Type power | 9 kW |
| Power loss at continuous current | 175 W |
| Mass | 8 kg |
| +24 V signal-processing load | 800 mA with LE5-024; 650 mA with AC fan units |
| ±15 V test-voltage loads | +150 mA / −60 mA |
| Fan-unit options | LE5-024, LE5-115 or LE5-220 |
| Protection | IP10 |
The W1 frame couples a 30 A current path to an external fan-assisted heat path without combining their electrical supplies.
The modular DC link feeds the servo power section through the busbars and bus connector.
The controller produces up to 30 A peak and 25 A continuous current through the A1/A2/A3 motor output.
Losses at continuous current must leave through the fan-assisted airflow route instead of accumulating around the module.
Cooling accessories, programming hardware and signal terminals occupy distinct positions around the controller front and heatsink.
LE5 fan units match 24 V DC, 115 V AC or 220 V AC supplies and remain external cooling accessories.
The programming module carries the controller/motor matching and current or speed scaling record.
Signal connectors, bus hardware and motor terminals remain accessible on the front while airflow passes through the cooling assembly.
For a site record covering TDM4.1-030-300-W1, photograph the MOD plate and keep its motor/controller code with the complete drive model.
When checking TDM4.1-030-300-W1, inspect the W1 code, fan model, fan voltage and free airflow before applying load.
To keep TDM4.1-030-300-W1 unambiguous, use the 30 A peak and 25 A continuous boundaries together with the exact motor and MOD settings.
When documenting TDM4.1-030-300-W1, check fan rotation, airflow obstruction, cabinet temperature and the 175 W loss path.
For TDM4.1-030-300-W1, inspect busbars, the bus connector, supply module and adjacent controllers only after the power is isolated.
Before work begins on TDM4.1-030-300-W1, match the LE5-024, LE5-115 or LE5-220 fan to the available auxiliary supply and confirm the required airflow direction before operation.
Moore Automation assigns one sales contact to industrial automation enquiries so exact product identity and commercial communication remain connected.
For this TDM4.1 controller, the full model, fan-unit record, requested documents, quotation notes, packing information and shipment updates can be coordinated through one enquiry path.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found