SERCOS carries the control-facing data for HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW.
Rexroth
Indramat
DIAX04 · TWO CURRENT FRAMES
Bosch Rexroth HDS03.2-W075N-HS32-01-FW / HDS03.2-W100N-HS32-01-FW DIAX04 HDS SERCOS Drive Controllers
Product Details
75 A / 100 ABosch Rexroth Indramat HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW are second-generation DIAX04 HDS drive controllers configured with SERCOS command communication. The HDS03.2 basic unit supplies the power stage, motor-feedback connection and local diagnostics, while plug-in modules and the HSM software module define the complete controller configuration.
Their current frames are not interchangeable data points. HDS03.2-W075N-HS32-01-FW uses the 75 A rated frame with 40 A continuous current at 4 kHz, whereas HDS03.2-W100N-HS32-01-FW uses the 100 A frame with 50 A continuous current at 4 kHz. The frame change also raises the published power loss from 220 W to 280 W.
On both HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW, SERCOS handles cyclic command exchange, X2 remains the serial parameterization and diagnostic path, and X4 receives motor feedback. The HSM software module stores firmware and parameter data independently of the power-frame size.
Specifications Overview
14 verified rows| Brand | Bosch Rexroth Indramat | |
|---|---|---|
| Product name | DIAX04 HDS SERCOS drive controller | |
| Basic unit | HDS03.2-W075N | HDS03.2-W100N |
| Configuration | HS32-01-FW | |
| Command communication | SERCOS interface | |
| Cooling | Internal air, built-in blower | |
| Rated / peak current | 75 A / 75 A | 100 A / 100 A |
| Continuous current at 4 / 8 kHz | 40 A / 30 A | 50 A / 35 A |
| Power loss at continuous current | 220 W | 280 W |
| Basic-unit weight | 11 kg | |
| Signal-processing consumption | 25 W from ±26 V source | |
| Serial service interface | RS232 / RS485 at X2 | |
| Rated ambient boundary | +5…+45 °C; up to 1000 m | |
| Protection / mounting | IP10 / closed cabinet | |
System Integration: SERCOS Commands and Local Feedback
Closed-loop structureThe SERCOS command module in HDS03.2-W075N-HS32-01-FW receives cyclic setpoints and returns status on the optical network. The motor-feedback path closes locally through X4, so network communication and encoder wiring retain separate boundaries.
The same signal organization applies to HDS03.2-W100N-HS32-01-FW. Its larger current frame changes power-stage capacity and heat loss but does not move the SERCOS, X2 or motor-feedback roles to different interfaces.
X4 returns motor position and speed information directly to the control electronics in each HDS03.2 frame.
The HSM software module retains firmware and parameter data, while the configuration plate records the installed modules.
Cabinet Coordination: Frame Identity, Heat Path and Switching Choice
Installation relationshipThe W075 and W100 frames occupy the same controller family, but the cabinet must preserve the relationship between the exact frame, the selected switching frequency and the air route through the enclosure.
The plate selects the thermal record
The complete HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW designation determines which loss record belongs in the cabinet calculation; equal mass does not make the heat contribution equal.
Switching choice changes usable load
Moving either HDS03.2 controller to 8 kHz changes the continuous-current boundary, so the motor load and the selected switching frequency are checked together rather than as separate settings.
Internal cooling joins drive and enclosure
The built-in blower moves cabinet air through each HDS03.2 frame. Inlet space, outlet space and the enclosure heat-removal path therefore form one installation condition.
Product Q&A
06 practical checks01A failed HDS03.2 controller is being replaced. How can HDS03.2-W075N-HS32-01-FW be kept separate from HDS03.2-W100N-HS32-01-FW?
Match the full HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW plate, then confirm the W075 or W100 basic unit before transferring the shared HS32 configuration. Their current frames and cabinet losses are different.
02Parameters must be retained during work on HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW. Which component carries them?
The HSM software module stores firmware and drive parameters for HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW; it is a separate record from the SERCOS command module and basic power frame.
03If SERCOS communication is healthy but commissioning access is unavailable, which route belongs to HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW?
Use X2 as the RS232/RS485 service route on HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW. The optical SERCOS path remains dedicated to cyclic machine commands and status.
04The cabinet calculation is being copied from HDS03.2-W075N-HS32-01-FW. Can it be reused unchanged for HDS03.2-W100N-HS32-01-FW?
No. HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW share an 11 kg basic-unit mass, but their published continuous-current losses are 220 W and 280 W, so the exact frame must drive the heat calculation.
05What should be rechecked before selecting 8 kHz on HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW?
Confirm the motor load against the 8 kHz continuous-current boundary of the exact HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW frame; the allowable continuous current is lower than at 4 kHz.
06How can a receiving inspection confirm the configured identity of HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW?
Photograph the complete HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW designation together with the configuration plate, HSM entry and SERCOS module so the frame and installed configuration remain one evidence set.
Our Services