Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth HDS03.2-W075N-HS32-01-FW / HDS03.2-W100N-HS32-01-FW DIAX04 HDS SERCOS Drive Controllers
Bosch Rexroth HDS03.2-W075N-HS32-01-FW / HDS03.2-W100N-HS32-01-FW DIAX04 HDS SERCOS Drive Controllers

Bosch Rexroth HDS03.2-W075N-HS32-01-FW / HDS03.2-W100N-HS32-01-FW DIAX04 HDS SERCOS Drive Controllers Item NO.: 2944316

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth HDS03.2-W075N-HS32-01-FW / HDS03.2-W100N-HS32-01-FW DIAX04 HDS SERCOS Drive Controllers
Item NO. 2944316
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-23

Bosch Rexroth HDS03.2-W075N-HS32-01-FW / HDS03.2-W100N-HS32-01-FW DIAX04 HDS SERCOS Drive Controllers
Bosch
Rexroth
Indramat

DIAX04 · TWO CURRENT FRAMES

Bosch Rexroth HDS03.2-W075N-HS32-01-FW / HDS03.2-W100N-HS32-01-FW DIAX04 HDS SERCOS Drive Controllers

HDS03.275 A / 100 A

Product Details

75 A / 100 A

Bosch Rexroth Indramat HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW are second-generation DIAX04 HDS drive controllers configured with SERCOS command communication. The HDS03.2 basic unit supplies the power stage, motor-feedback connection and local diagnostics, while plug-in modules and the HSM software module define the complete controller configuration.

Their current frames are not interchangeable data points. HDS03.2-W075N-HS32-01-FW uses the 75 A rated frame with 40 A continuous current at 4 kHz, whereas HDS03.2-W100N-HS32-01-FW uses the 100 A frame with 50 A continuous current at 4 kHz. The frame change also raises the published power loss from 220 W to 280 W.

On both HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW, SERCOS handles cyclic command exchange, X2 remains the serial parameterization and diagnostic path, and X4 receives motor feedback. The HSM software module stores firmware and parameter data independently of the power-frame size.

Specifications Overview

14 verified rows
AttributeHDS03.2-W075N-HS32-01-FWHDS03.2-W100N-HS32-01-FW
Brand Bosch Rexroth Indramat
Product name DIAX04 HDS SERCOS drive controller
Basic unit HDS03.2-W075N HDS03.2-W100N
Configuration HS32-01-FW
Command communication SERCOS interface
Cooling Internal air, built-in blower
Rated / peak current 75 A / 75 A 100 A / 100 A
Continuous current at 4 / 8 kHz 40 A / 30 A 50 A / 35 A
Power loss at continuous current 220 W 280 W
Basic-unit weight 11 kg
Signal-processing consumption 25 W from ±26 V source
Serial service interface RS232 / RS485 at X2
Rated ambient boundary +5…+45 °C; up to 1000 m
Protection / mounting IP10 / closed cabinet

System Integration: SERCOS Commands and Local Feedback

Closed-loop structure

The SERCOS command module in HDS03.2-W075N-HS32-01-FW receives cyclic setpoints and returns status on the optical network. The motor-feedback path closes locally through X4, so network communication and encoder wiring retain separate boundaries.

The same signal organization applies to HDS03.2-W100N-HS32-01-FW. Its larger current frame changes power-stage capacity and heat loss but does not move the SERCOS, X2 or motor-feedback roles to different interfaces.

Optical command path

SERCOS carries the control-facing data for HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW.

Local feedback path

X4 returns motor position and speed information directly to the control electronics in each HDS03.2 frame.

Stored drive context

The HSM software module retains firmware and parameter data, while the configuration plate records the installed modules.

Cabinet Coordination: Frame Identity, Heat Path and Switching Choice

Installation relationship

The W075 and W100 frames occupy the same controller family, but the cabinet must preserve the relationship between the exact frame, the selected switching frequency and the air route through the enclosure.

FRAME

The plate selects the thermal record

The complete HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW designation determines which loss record belongs in the cabinet calculation; equal mass does not make the heat contribution equal.

FREQUENCY

Switching choice changes usable load

Moving either HDS03.2 controller to 8 kHz changes the continuous-current boundary, so the motor load and the selected switching frequency are checked together rather than as separate settings.

AIR

Internal cooling joins drive and enclosure

The built-in blower moves cabinet air through each HDS03.2 frame. Inlet space, outlet space and the enclosure heat-removal path therefore form one installation condition.

Product Q&A

06 practical checks
01A failed HDS03.2 controller is being replaced. How can HDS03.2-W075N-HS32-01-FW be kept separate from HDS03.2-W100N-HS32-01-FW?

Match the full HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW plate, then confirm the W075 or W100 basic unit before transferring the shared HS32 configuration. Their current frames and cabinet losses are different.

02Parameters must be retained during work on HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW. Which component carries them?

The HSM software module stores firmware and drive parameters for HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW; it is a separate record from the SERCOS command module and basic power frame.

03If SERCOS communication is healthy but commissioning access is unavailable, which route belongs to HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW?

Use X2 as the RS232/RS485 service route on HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW. The optical SERCOS path remains dedicated to cyclic machine commands and status.

04The cabinet calculation is being copied from HDS03.2-W075N-HS32-01-FW. Can it be reused unchanged for HDS03.2-W100N-HS32-01-FW?

No. HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW share an 11 kg basic-unit mass, but their published continuous-current losses are 220 W and 280 W, so the exact frame must drive the heat calculation.

05What should be rechecked before selecting 8 kHz on HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW?

Confirm the motor load against the 8 kHz continuous-current boundary of the exact HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW frame; the allowable continuous current is lower than at 4 kHz.

06How can a receiving inspection confirm the configured identity of HDS03.2-W075N-HS32-01-FW and HDS03.2-W100N-HS32-01-FW?

Photograph the complete HDS03.2-W075N-HS32-01-FW or HDS03.2-W100N-HS32-01-FW designation together with the configuration plate, HSM entry and SERCOS module so the frame and installed configuration remain one evidence set.

Our Services

Moore Automation

Moore Automation Limited

https://www.mvme.cn/

Moore Automation Limited supports enquiries for industrial drives, control hardware and automation components. Each HDS03.2 frame is recorded with its full configuration suffix so commercial documents preserve the technical identity supplied by the customer.

The account contact can coordinate requested product records, quotation data and delivery communication across a multi-line enquiry.

Drive and control enquiriesFrame-specific recordsQuotation coordinationMulti-line order support

Recommended Models

60 model references
Siemens 6ES7214-1HG40-0XB0
ABB PM564-RP
Bently Nevada 330106-05-30-10-02-00
Allen-Bradley 1794-IA16
Emerson IC694MDL740
GE IC660BBD100
B&R X20CS1030
Bosch Rexroth HCS01.1E-W0054-A-03-B-ET-EC-NN-L3-NN-FW
Vibro-Meter CE281
Motorola MVME2306
Siemens 6ES7215-1AG40-0XB0
ABB PM564-RP-AC
Bently Nevada 330106-05-30-10-02-05
Allen-Bradley 1794-AENT
Emerson IC694ALG223
GE IC660BBD101
B&R X20IF10E1-1
Bosch Rexroth DDS02.1-W050-D
Vibro-Meter CE620
Motorola MVME2307
Siemens 6ES7215-1BG40-0XB0
ABB PM572
Bently Nevada 330180-50-00
Allen-Bradley 1794-AENTR
Emerson IC200CPUE05
GE IC660BBD110
B&R X20IF2772
Vibro-Meter CV210
Motorola MVME2308
Siemens 6ES7215-1HG40-0XB0
ABB PM582
Bently Nevada 330180-50-05
Allen-Bradley 1794-ACN15
Emerson IC200MDL650
GE IC660BBD120
B&R X20BM01
Bosch Rexroth DDS02.1-W200-D
Motorola MVME2604
Siemens 6ES7217-1AG40-0XB0
ABB PM573-ETH-XC
Bently Nevada 330180-51-00
Allen-Bradley 1794-ACNR15
Emerson IC200MDL740
GE IC660BBR100
B&R X20BM12
Bosch Rexroth DDS02.2-W050-BE12-01-FW
Motorola MVME2604-712
Siemens 6ES7217-1BG40-0XB0
ABB PM583-ETH-XC
Bently Nevada 330180-51-05
Allen-Bradley 1794-ASB
Emerson IC200ALG264
GE IC660BBR101
B&R X20BM15
Bosch Rexroth DDS02.2-W100-BE12-01-FW
Motorola MVME2604-761
Siemens 6ES7212-1AF40-0XB0
ABB PM591-ETH-XC
Bently Nevada 330180-90-00
Allen-Bradley 1794-IB16
Enquiry DetailsStart an enquiry
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.