Bosch Rexroth HMV01.1R-W0065-A-07-NNNN IndraDrive M Regenerative Supply Unit
Product Details
65 kW / 700 V DC BUSBosch Rexroth HMV01.1R-W0065-A-07-NNNN is a regenerative IndraDrive M supply unit that links three-phase mains power to the common DC bus used by modular drive controllers. Its main task is to rectify incoming mains energy for the DC bus and return regenerated drive energy toward the mains through the regenerative power section instead of assigning that function to each connected inverter.
On HMV01.1R-W0065-A-07-NNNN, 3 × AC 400…480 V passes through the required mains filter and HNL mains choke before reaching X3. The internal mains contactor and converter feed the DC bus at L+ and L−, while the 24 V control-voltage bus and X1 module bus continue across the modular drive line. X14 supplies mains-voltage synchronization required by the regenerative design.
Control and status wiring of HMV01.1R-W0065-A-07-NNNN is divided by function: X2 provides RS232 service communication, X31 carries status messages, X32 handles mains-contactor control and DC-bus short-circuit control, and X33 provides power acknowledgements. Optional HLC capacity and HLB brake modules connect at the DC bus rather than at the low-voltage signal connectors.
Specifications Overview
16 verified rows| Brand | Bosch Rexroth |
|---|---|
| Product name | IndraDrive M regenerative supply unit |
| Material number | R911297426 |
| Continuous DC-bus power | 65 kW with mains choke |
| Mains input | 3 × AC 400…480 V (+10/−15%) |
| Rated input current | 94 A |
| Nominal DC-bus voltage | 700 V DC |
| Output voltage / current | 750 V DC / 87 A |
| Cooling | Air, internal integrated blower |
| Control-voltage input | 24 V DC ±5% |
| Control-supply consumption | 108 W / 4.5 A |
| Width / height / depth | 350 / 440 / 309 mm |
| Mass | 31 kg |
| Protection | IP20 |
| Regenerative synchronization | X14 mains-voltage synchronization |
| Service interface | RS232 at X2 |
Mains Energy and Regenerated Drive Energy Share a Controlled Path
Bidirectional power flowMains power reaches HMV01.1R-W0065-A-07-NNNN through the external filter and the HNL mains choke. The internal contactor and regenerative converter establish the DC bus used by the connected IndraDrive M inverters.
When a connected motor regenerates, energy returns through the common L+/L− bus to HMV01.1R-W0065-A-07-NNNN. The synchronization signal at X14 lets the regenerative section align this returned energy with the three-phase mains rather than dissipating all of it locally.
L+ and L− distribute power to drive modules
X14 follows mains voltage
Control, Status and Module-Bus Connections Remain Functionally Separate
Interface organizationThe connection groups of HMV01.1R-W0065-A-07-NNNN prevent service communication, contactor control and power acknowledgement from being treated as one signal path.
Messages and power acknowledgements
X31 reports supply-unit status while X33 provides power acknowledgements to the external control circuit.
Mains-contactor and DC-bus control
X32 carries the control signals for the mains contactor and DC-bus short-circuit circuit.
Module bus and control voltage continue through the line
The X1 module bus and 24 V control bus link HMV01.1R-W0065-A-07-NNNN with neighboring IndraDrive M modules.
Product Q&A
06 practical checks01Why is an HNL mains choke required with HMV01.1R-W0065-A-07-NNNN?
The regenerative topology of HMV01.1R-W0065-A-07-NNNN uses the specified HNL mains choke between the filter and X3 as part of the controlled mains and return-energy path.
02Which connector synchronizes HMV01.1R-W0065-A-07-NNNN with the mains?
X14 on HMV01.1R-W0065-A-07-NNNN receives mains-voltage synchronization so the regenerative converter has the required phase reference.
03Where does HMV01.1R-W0065-A-07-NNNN distribute DC-bus power?
HMV01.1R-W0065-A-07-NNNN distributes the common DC bus through L+ and L− to the connected IndraDrive M power sections.
04What must be connected to X32 on HMV01.1R-W0065-A-07-NNNN?
X32 of HMV01.1R-W0065-A-07-NNNN is assigned to mains-contactor control and DC-bus short-circuit control, not to RS232 service communication.
05How is service communication accessed on HMV01.1R-W0065-A-07-NNNN?
Use the RS232 interface at X2 for service access to HMV01.1R-W0065-A-07-NNNN; X31 and X33 have separate message and acknowledgement roles.
06Which physical data should be reserved for HMV01.1R-W0065-A-07-NNNN?
Allow for the 350 mm width, 440 mm maximum height, 309 mm depth and 31 kg mass of HMV01.1R-W0065-A-07-NNNN, together with the required internal-air cooling clearance.