Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE IC200PWR102K VersaMax 120/240 V AC Expanded 3.3 V Power Supply
GE IC200PWR102K VersaMax 120/240 V AC Expanded 3.3 V Power Supply

GE IC200PWR102K VersaMax 120/240 V AC Expanded 3.3 V Power Supply Item NO.: 2944343

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE IC200PWR102K VersaMax 120/240 V AC Expanded 3.3 V Power Supply
Item NO. 2944343
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-23

GE IC200PWR102K VersaMax 120/240 V AC Expanded 3.3 V Power Supply
GEVersaMax Power
AC120/240 V input
Expanded backplane supply

GE IC200PWR102K VersaMax 120/240 V AC Expanded 3.3 V Power Supply

Expanded 3.3 V backplane capacity with selectable nominal AC input.

Product Information

GE IC200PWR102K is the VersaMax 120/240 V AC expanded 3.3 V power supply for CPUs, network interface units and I/O stations. It produces both 5 V and 3.3 V backplane outputs with an expanded share available on the 3.3 V rail.

The input of GE IC200PWR102K accepts the specified 120 V or 240 V AC ranges. A jumper identifies 120 V nominal operation; 240 V operation is performed without that jumper.

GE IC200PWR102K can serve as the main station supply when mounted on a CPU or NIU, or as a supplemental supply on a power-supply booster carrier. Its combined output must remain within the published current relationship.

Technical Data

GE IC200PWR102K
Specification Value
Brand GE
Product Name VersaMax 120/240 V AC Expanded 3.3 V Power Supply
Series VersaMax
Input Range at 120 V 85 to 132 V AC with jumper installed
Input Range at 240 V 176 to 264 V AC without jumper
Input Frequency 47 to 63 Hz
Input Power 27 VA
Hold-Up Time 20 ms
Output Voltages 5 V DC and 3.3 V DC
Specification Value
Total Output Current 1.5 A maximum
3.3 V Output 1.0 A maximum
5 V Output 1.5 A minus 3.3 V output current
Protection Short circuit and overload
120 V Selection Jumper installed
240 V Selection No jumper
Station Role Main CPU/NIU power supply or booster supply
Mounting Option Power Supply Booster Carrier for supplemental use

Power Conversion and Backplane Distribution

GE IC200PWR102K converts the station AC input into two regulated backplane rails shared by the controller and installed modules.

INPUT

Wide nominal AC operation

Separate published ranges cover 120 V and 240 V systems, with the jumper state identifying the intended nominal input.

5 V

Primary backplane rail

The 5 V output supports modules whose current demand is assigned to the standard VersaMax backplane supply.

3.3 V

Expanded low-voltage rail

Up to 1.0 A is available on 3.3 V, with the combined output still limited by the total current relationship.

Jumper and Hold-Up Behavior

The GE IC200PWR102K input jumper and energy-storage interval define how the supply is applied and how it rides through a short input interruption.

120 V

Jumper required

The jumper is installed only for the 120 V nominal input range so the supply interprets the lower AC range correctly.

240 V

Jumper prohibited

The jumper is removed for 240 V nominal operation; fitting it at 240 V can damage the supply.

20 MS

Brief continuity interval

The published hold-up interval sustains the outputs through a short input loss before the station experiences a power interruption.

Product Questions

Why must the jumper be checked before energizing GE IC200PWR102K?

GE IC200PWR102K requires the jumper for 120 V nominal service and no jumper for 240 V; the wrong state can create unsafe operation or damage.

How is the 1.5 A rating shared on GE IC200PWR102K?

On GE IC200PWR102K, the 3.3 V demand subtracts from the available 5 V share, so calculate both rails together rather than treating each maximum independently.

Can GE IC200PWR102K be used as a supplemental supply?

Yes. GE IC200PWR102K can be mounted on the specified booster carrier when the station needs additional backplane capacity.

What can cause a GE IC200PWR102K station to reset under load?

Check GE IC200PWR102K input range, terminal tightness, 5 V and 3.3 V load totals, module current requirements and short-circuit or overload conditions.

What does the GE IC200PWR102K hold-up time represent?

The GE IC200PWR102K 20 ms hold-up value is a brief ride-through interval, not a substitute for an external UPS during longer AC interruptions.

Which data should accompany a GE IC200PWR102K enquiry?

Provide GE IC200PWR102K exactly, nominal input voltage, station role, module load context, quantity, condition and destination.

Power Module Documentation

Moore Automation

https://www.mvme.cn/

Moore Automation supports power-module enquiries with clear lead-time communication, reliable carrier options and secure packing for shipment. For GE IC200PWR102K, the nominal input class, jumper requirement and main-or-booster station role remain attached to the quotation record.

Accurate lead timeAvailability is communicated before dispatch
Reliable carriersShipment options match the destination
Secure packingPower-module faces and terminals protected

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.