Locate the motor continuous current on the W150 loss curve for DDS02.1-W150-D.
Rexroth
Indramat
DIAX02 · 150 A FRAME
Bosch Rexroth DDS02.1-W150-D DIAX02 Digital AC Servo Drive Controller
Product Summary
W150 / DIGITAL FEEDBACKBosch Rexroth Indramat DDS02.1-W150-D is a DIAX02 digital AC servo drive controller basic unit with a 150 A power stage and digital servo feedback. Installed in the cabinet drive line, it receives DC-bus energy from the DIAX supply unit, switches that energy to the motor and closes the motion loop through the connected digital feedback system.
The W150 power section of DDS02.1-W150-D is combined with a modular control assembly. Command communication and auxiliary functions occupy U1–U4, while U5 contains the software module with firmware and parameter data. The hardware and firmware configuration plates preserve which modules belong to the assembled controller.
Heat produced by DDS02.1-W150-D is removed by the specified internal cabinet airflow. The manual relates cabinet heat loss to motor continuous current, so the enclosure calculation follows the actual continuous operating point rather than treating the 150 A current-frame code as a constant thermal load.
Specification Details
14 verified rows| Brand | Bosch Rexroth Indramat |
|---|---|
| Product name | DIAX02 digital AC servo drive controller |
| Series / basic unit | DDS02.1 |
| Current frame | W150 |
| Feedback version | Digital servo feedback |
| Cooling | Air, inside control cabinet |
| DC-bus input | 300 V DC ±15% |
| Maximum peak current | 150 A |
| Maximum continuous current | 105 A |
| Signal supplies | +24 V and ±15 V |
| Plug-in module positions | U1–U4 |
| Software module position | U5 |
| Rated ambient boundary | 0…+45 °C; up to 1000 m |
| Protection / mounting | IP20 / vertical cabinet mounting |
Continuous Motor Load Determines Cabinet Heat
Thermal behaviorThe energy-loss curve for DDS02.1-W150-D relates enclosure heat to the motor continuous current at standstill. This means the cabinet calculation uses the operating current of the connected motor rather than copying only the maximum current-frame value.
Internal airflow carries the calculated heat from DDS02.1-W150-D into the control cabinet. The enclosure ventilation must therefore be sized for the controller loss together with the other cabinet components at the intended operating point.
Use the corresponding curve value as the controller contribution to cabinet heat.
Maintain the required vertical airflow and free space so the heat can leave the power section.
Configuration Plates Link the Power Frame to Its Modules
Hardware identityThe W150 basic unit is only one layer of the complete DDS02.1-W150-D controller identity.
W150 identifies the power stage
The 150 A peak and 105 A continuous-current boundary belong to the basic unit of DDS02.1-W150-D.
U1–U4 identify installed interfaces
The hardware configuration plate records command communication and auxiliary modules by slot.
U5 carries firmware and parameters
The software module links the stored operating data to the assembled DDS02.1-W150-D configuration.
Questions & Answers
06 practical checks01How should cabinet heat be calculated for DDS02.1-W150-D?
Use the motor continuous current at standstill with the W150 energy-loss curve for DDS02.1-W150-D, then add the resulting controller loss to the other cabinet heat sources.
02What does the W150 field identify on DDS02.1-W150-D?
W150 identifies the power-stage current frame of DDS02.1-W150-D; the published maximum peak current is 150 A and maximum continuous current is 105 A.
03Which plates define the assembled DDS02.1-W150-D controller?
The basic-unit plate, hardware configuration plate and firmware configuration plate together identify DDS02.1-W150-D and its installed modules.
04Where are command and auxiliary modules installed on DDS02.1-W150-D?
The command-communication and auxiliary plug-in modules of DDS02.1-W150-D occupy U1–U4, with each position recorded on the hardware configuration plate.
05What is stored in U5 on DDS02.1-W150-D?
U5 of DDS02.1-W150-D contains the software module with firmware and drive parameter context.
06Which environmental limits preserve rated data for DDS02.1-W150-D?
Rated data for DDS02.1-W150-D applies from 0 to +45 °C and up to 1000 m installation elevation in an IP20 cabinet installation.