The supply begins at L+ and L−
HMS02.1N-W0028-A-07-NNNN and HMS02.1N-W0054-A-07-NNNN do not rectify AC mains. Their input stage starts at the IndraDrive M DC bus, which supplies the internal inverter bridge.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bosch Rexroth HMS02.1N-W0028-A-07-NNNN / HMS02.1N-W0054-A-07-NNNN IndraDrive M Motor Inverters |
| Item NO. | 2942588 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BOSCH |
| Brand | BOSCH |
| Creation Time | 2026-11-19 |
Bosch Rexroth HMS02.1N-W0028-A-07-NNNN and HMS02.1N-W0054-A-07-NNNN are compact IndraDrive M HMS02 motor inverters. They receive 254–750 V DC from the drive bus and generate a controlled three-phase output up to 500 V for the connected motor axis.
HMS02.1N-W0028-A-07-NNNN draws 18.4 A from the DC bus and supplies 13.8 A, while HMS02.1N-W0054-A-07-NNNN draws 30.7 A and supplies 25 A. Their maximum-current limits are 28.3 A and 54 A, so the W code and continuous-current row describe different operating boundaries.
Forced ventilation moves 17.2 m³/h through HMS02.1N-W0028-A-07-NNNN and 37 m³/h through HMS02.1N-W0054-A-07-NNNN. The 50 mm and 75 mm frames dissipate 150 W and 350 W continuously, linking the model-specific width, fan demand and current capacity.
| Attribute | HMS02.1N-W0028-A-07-NNNN | HMS02.1N-W0054-A-07-NNNN |
|---|---|---|
| 01Brand | Bosch Rexroth | Bosch Rexroth |
| 02Product type | Motor inverter | Motor inverter |
| 03Series | IndraDrive M HMS02 | IndraDrive M HMS02 |
| 04DC-bus input | DC 254…750 V | DC 254…750 V |
| 05Output voltage | 3 × AC 0…500 V | 3 × AC 0…500 V |
| 06DC input current | 18.4 A | 30.7 A |
| 07Output current | 13.8 A | 25 A |
| 08Maximum output current | 28.3 A | 54 A |
| 09Switching frequencies | 4 / 8 kHz | 4 / 8 / 12 / 16 kHz |
| 10Control-voltage input | 24 V ±20% | 24 V ±20% |
| 11Control power | 13 W | 17 W |
| 12Continuous power dissipation | 150 W | 350 W |
| 13Airflow | 17.2 m³/h | 37 m³/h |
| 14Housing width | 50 mm | 75 mm |
| 15Mass | 3.5 kg | 5.0 kg |
The HMS02 receives an already established DC bus, controls one motor output and returns regenerative energy to the same bus.
HMS02.1N-W0028-A-07-NNNN and HMS02.1N-W0054-A-07-NNNN do not rectify AC mains. Their input stage starts at the IndraDrive M DC bus, which supplies the internal inverter bridge.
The inverter of HMS02.1N-W0028-A-07-NNNN or HMS02.1N-W0054-A-07-NNNN switches the bus voltage into three controlled phases. The current row belongs to that output stage at the stated switching frequency.
Returned motor energy passes through HMS02.1N-W0028-A-07-NNNN or HMS02.1N-W0054-A-07-NNNN back to L+/L−. Braking capacity is determined by the wider drive system rather than an internal mains/braking section.
A 25 mm increase in frame width accompanies changes in current, airflow, frequency options and control demand.
HMS02.1N-W0028-A-07-NNNN is documented at 4 and 8 kHz, whereas HMS02.1N-W0054-A-07-NNNN also includes 12 and 16 kHz. A configuration list from W0054 must not be applied to W0028.
The 150 W loss of HMS02.1N-W0028-A-07-NNNN is paired with 17.2 m³/h, while the 350 W loss of HMS02.1N-W0054-A-07-NNNN is paired with 37 m³/h. Both conditions depend on clear top and bottom airflow.
The 24 V control input is common, but HMS02.1N-W0028-A-07-NNNN uses 13 W and HMS02.1N-W0054-A-07-NNNN uses 17 W. The cabinet control supply therefore retains the exact model row.
For HMS02.1N-W0028-A-07-NNNN / HMS02.1N-W0054-A-07-NNNN, retain the model-specific control-power values of 13 W and 17 W and add the documented control-side loads for the complete axis.
W0028 is documented for 4 and 8 kHz; W0054 is documented for 4, 8, 12 and 16 kHz. This condition belongs to HMS02.1N-W0028-A-07-NNNN / HMS02.1N-W0054-A-07-NNNN.
When checking HMS02.1N-W0028-A-07-NNNN / HMS02.1N-W0054-A-07-NNNN, the specified forced-air values are 17.2 m³/h for W0028 and 37 m³/h for W0054.
Use the full type plate and the 50 mm or 75 mm frame view; current and frequency data should remain beside that exact model. Keep this requirement with HMS02.1N-W0028-A-07-NNNN / HMS02.1N-W0054-A-07-NNNN.
HMS02.1N-W0028-A-07-NNNN / HMS02.1N-W0054-A-07-NNNN should be recorded with this result: 28.3 A is maximum output current, while 13.8 A is the published output-current row; the two values describe different limits.
HMS02.1N-W0028-A-07-NNNN / HMS02.1N-W0054-A-07-NNNN: No. Both are DC-bus-fed motor inverters and receive DC 254–750 V at L+/L−.
Moore Automation supports multi-brand automation enquiries, including rare, discontinued and hard-to-find components. The company reference material combines inventory access, global sourcing, international delivery and secure packaging as one supply workflow.
HMS02.1N-W0028-A-07-NNNN and HMS02.1N-W0054-A-07-NNNN remain separate so width, frequency capability and control-power evidence stay attached to the correct type plate.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found