Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth KDA3.2-100-3-A00-W1 KDA 3 Modular Main Spindle Drive
Bosch Rexroth KDA3.2-100-3-A00-W1 KDA 3 Modular Main Spindle Drive

Bosch Rexroth KDA3.2-100-3-A00-W1 KDA 3 Modular Main Spindle Drive Item NO.: 2944324

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth KDA3.2-100-3-A00-W1 KDA 3 Modular Main Spindle Drive
Item NO. 2944324
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-23

Bosch Rexroth KDA3.2-100-3-A00-W1 KDA 3 Modular Main Spindle Drive
Bosch
Rexroth
Indramat

KDA 3 · ANALOG COMMAND

Bosch Rexroth KDA3.2-100-3-A00-W1 KDA 3 Modular Main Spindle Drive

KDA3.2100 A / 300 V DC

Model Overview

100 A / 300 V DC

Bosch Rexroth Indramat KDA3.2-100-3-A00-W1 is a 100 A modular main spindle drive for Indramat 2AD asynchronous and 1MB frameless spindle motors. The microcomputer-controlled unit regulates spindle speed and position, receives a ±10 V analog command through the A interface and coordinates the motor power stage with feedback and stored operating parameters.

The modular drive chain of KDA3.2-100-3-A00-W1 separates energy, control and feedback connections. DC-bus power enters from the supply module, the inverter feeds the main spindle motor through the motor power cable, and the motor-feedback cable returns rotor information. A serial interface provides parameter storage and loading to a PC without becoming the real-time analog command path.

Cooling for KDA3.2-100-3-A00-W1 uses the W1 forced-air arrangement with a heatsink blower and external air duct. Most power-stage heat is carried outside the sealed control enclosure through the rear heatsink, while the programming module stores the drive operating software and machine-specific parameters separately from the power hardware.

Technical Details

15 verified rows
AttributeKDA3.2-100-3-A00-W1
Brand Bosch Rexroth Indramat
Product name KDA 3 modular main spindle drive
Series / design KDA3.2
Type current 100 A
DC-bus voltage class 300 V DC
Command interface ±10 V analog speed command
Motor feedback option Standard feedback input
Additional encoder input None
Auxiliary interface None
Cooling option W1 forced cooling
Programming module AS3
Housing width / depth 150 mm / 325 mm
Device mass 17.1 kg
Mounting orientation Vertical
Rated ambient boundary +5…+45 °C; up to 1000 m

Supply Module, KDA Drive and Spindle Motor Form One Chain

Component allocation

The supply module delivers DC-bus energy to KDA3.2-100-3-A00-W1. Its inverter converts that energy for the main spindle motor, while the separate feedback cable returns motor position and speed information to the control electronics.

The allocation diagram keeps the programming module, electrical connection accessories, motor power cable, motor-feedback cable, heatsink blower and air duct as distinct components around KDA3.2-100-3-A00-W1. Each part has a defined role in power conversion, data storage or cooling.

Energy path

Supply-module DC power enters KDA3.2-100-3-A00-W1 and leaves as controlled motor power.

Feedback path

The motor-feedback cable closes the spindle-control loop independently of the analog command input.

Stored data

The AS3 programming module carries operating software and the drive/machine parameter set.

External Heatsink Airflow Keeps Most Heat Outside the Cabinet

Thermal path

The W1 cooling arrangement divides internal electronics cooling from the external heatsink airflow.

HEATSINK

Power-stage heat moves rearward

The rear heatsink of KDA3.2-100-3-A00-W1 conducts most generated heat out of the sealed enclosure.

BLOWER

Forced air crosses the external fins

The heatsink blower and air duct create the defined external airflow rather than circulating that heat through the control electronics.

ENCLOSURE

Internal and external losses remain separate

Cabinet planning uses the internal loss for enclosure heat and the external loss for the blower/duct path.

Customer Questions

06 practical checks
01What command signal must be provided to KDA3.2-100-3-A00-W1?

KDA3.2-100-3-A00-W1 uses the A-interface ±10 V analog speed command; the serial interface is for parameter storage and loading, not real-time speed command.

02Which module stores the operating data of KDA3.2-100-3-A00-W1?

The AS3 programming module of KDA3.2-100-3-A00-W1 stores operating software plus drive-specific and application-specific parameters.

03How does motor energy flow through KDA3.2-100-3-A00-W1?

DC-bus power from the supply module enters KDA3.2-100-3-A00-W1, and its inverter sends controlled three-phase power to the main spindle motor.

04Where does the motor feedback connect on KDA3.2-100-3-A00-W1?

The dedicated motor-feedback cable returns spindle-motor signals to KDA3.2-100-3-A00-W1; it is separate from the analog command and motor-power cables.

05What cooling hardware belongs to KDA3.2-100-3-A00-W1?

The W1 version of KDA3.2-100-3-A00-W1 uses a heatsink blower and external air duct to remove most power-stage heat outside the control enclosure.

06How must KDA3.2-100-3-A00-W1 be mounted?

KDA3.2-100-3-A00-W1 is mounted vertically with the specified blower/duct clearance so the external heatsink airflow is not obstructed.

Brand Supply and Enquiry Services

Moore Automation

Moore Automation Limited

https://www.mvme.cn/

Moore Automation Limited supports enquiries across established industrial automation and drive brands. Each requested type code is kept on its own commercial line with available documentation.

Account coordination covers quotation information, exact-model review and shipment communication.

Established brandsExact-model reviewQuotation coordinationShipment communication

Related Models

60 model references
Allen-Bradley 1764-LRP
GE IC754VBB06CTD
B&R X67SM4320
Motorola MVME6100-0171
Siemens 6ES7290-6AA30-0XA0
ABB ACS580-01-062A-4
Bently Nevada 3500/94
Allen-Bradley 1764-LSP
GE IC754VSI06MTD
B&R 8V1022.00-2
Motorola MVME6100-0173
Siemens 6ES7292-1AG30-0XA0
ABB ACS580-01-073A-4
Bently Nevada 3500/94M
Allen-Bradley 1762-IF4
GE IC754VBI06MTD
B&R 8V1016.00-2
Motorola MVME61006E-0161
Siemens 6ES7292-1AH30-0XA0
ABB ACS580-01-088A-4
Bently Nevada 330901-0-90-10-02-05
Allen-Bradley 1762-OF4
GE IC754VKI06MTD
B&R 8V1010.00-2
Motorola MVME61006E-0161R
Siemens 6EP1332-1SH71
ABB ACS580-01-106A-4
Bently Nevada 330903-00-07-10-01-00
Allen-Bradley 1762-IR4
GE IC754VBF12CTD
B&R 8V1045.00-2
Motorola MVME61006E-0163
Siemens 6ES7511-1AK02-0AB0
ABB ACS580-01-145A-4
Bently Nevada 330903-00-07-10-01-CN
Allen-Bradley 1762-OB16
GE IC754VBI12CTD
B&R 8V1090.00-2
Motorola MVME61006E-0163R
Siemens 6ES7511-1CK01-0AB0
ABB ACS580-01-169A-4
Bently Nevada 330905-0-25-05-02-IN
Allen-Bradley 1761-NET-ENI
GE IC754VBI12MTD
B&R 8V1180.00-2
Motorola MVME61006E-0171
Siemens 6ES7512-1DK01-0AB0
ABB ACS580-01-206A-4
Bently Nevada 330908-21-35-10-02-00
Allen-Bradley 1761-NET-AIC
GE IC754CBF15CTD
B&R 8V128M.00-2
Motorola MVME61006E-0173
Siemens 6ES7513-1AL02-0AB0
ABB ACS510-01-09A4-4
Bently Nevada 330909-00-25-10-02-00
Allen-Bradley 1772-LR
GE IC754CKF15CTD
B&R 8V1320.00-2
Siemens 6ES7513-1FL02-0AB0
Sales ContactStart an enquiry
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.