The analog setpoint enters through the control-facing module assigned to HDS02.2-W040N-HA01-01-FW.
Rexroth
Indramat
DIAX04 · ANALOG COMMAND
Bosch Rexroth HDS02.2-W040N-HA01-01-FW DIAX04 HDS Analog Drive Controller
Model Overview
40 A / HA01Bosch Rexroth Indramat HDS02.2-W040N-HA01-01-FW is a second-generation DIAX04 HDS drive controller configured with an analog command interface. Its HDS02.2-W040N basic unit contains the 40 A power stage, motor-feedback connection and local diagnostics, while the HA01 command module, HSM software module and recorded U-slot modules complete the configured controller.
The modular structure of HDS02.2-W040N-HA01-01-FW keeps the command path separate from stored drive data. The analog command module receives the control-facing setpoint, the HSM software module holds firmware and parameters, X2 remains the RS232/RS485 service route, and X4 returns motor-feedback signals to the control electronics.
Power for HDS02.2-W040N-HA01-01-FW enters from the neighboring DIAX supply unit through the integrated control bus and L+/L− DC bus. The controller switches that DC energy to the motor at X5, while X6 groups motor-temperature monitoring, holding-brake wiring and the external 24 V brake supply.
Technical Details
15 verified rows| Brand | Bosch Rexroth Indramat |
|---|---|
| Product name | DIAX04 HDS analog drive controller |
| Basic unit | HDS02.2-W040N |
| Configuration code | HA01-01-FW |
| Command communication | Analog interface |
| Cooling | Internal air, built-in blower |
| Rated / peak current | 40 A / 40 A |
| Continuous current at 4 / 8 kHz | 20 A / 15 A |
| Power loss at continuous current | 125 W |
| Basic-unit weight | 6.5 kg |
| Signal-processing consumption | 20 W from ±26 V source |
| Serial service interface | RS232 / RS485 at X2 |
| Motor feedback | X4 |
| Rated ambient boundary | +5…+45 °C; up to 1000 m |
| Protection / mounting | IP10 / closed cabinet |
Configured Controller: Analog Command and Stored Drive Data
Module organizationThe HA01 command module in HDS02.2-W040N-HA01-01-FW converts the external analog command into the control input used by the drive electronics. Its function is distinct from the HSM software module, which carries firmware and the parameter set.
The configuration plate of HDS02.2-W040N-HA01-01-FW records the basic unit, command module, software module and occupied U slots. Reading these fields together identifies the assembled controller rather than only the W040N power frame.
Firmware and drive parameters remain stored separately from the analog interface hardware.
The plate links the basic unit and every installed module to the complete controller code.
DC Bus, Feedback and Motor Connections Keep Separate Roles
Electrical boundariesThe front connection groups of HDS02.2-W040N-HA01-01-FW separate cabinet-bus power, motor feedback and load wiring.
Supply unit feeds X1 and L+/L−
The adjacent supply unit provides the control bus and DC-bus energy used by HDS02.2-W040N-HA01-01-FW.
X4 closes the motor loop
Position and speed information returns through X4 without sharing the analog-command or serial-service connector.
X5 and X6 divide motor circuits
X5 carries three-phase motor power, while X6 carries temperature, brake and external 24 V brake-supply wiring.
Customer Questions
06 practical checks01How can the complete configuration of HDS02.2-W040N-HA01-01-FW be verified?
Read the configured-controller code, HDS02.2-W040N basic-unit code, HA01 command module, HSM software module and U-slot entries together for HDS02.2-W040N-HA01-01-FW.
02Which command signal belongs to HDS02.2-W040N-HA01-01-FW?
HDS02.2-W040N-HA01-01-FW uses the HA01 analog command interface; X2 is the separate RS232/RS485 parameterization and diagnostic route.
03Where does HDS02.2-W040N-HA01-01-FW receive DC-bus energy?
HDS02.2-W040N-HA01-01-FW receives DC-bus power at L+/L− from the neighboring DIAX supply unit and control-bus power through X1.
04What current must be used at 8 kHz for HDS02.2-W040N-HA01-01-FW?
The continuous-current boundary of HDS02.2-W040N-HA01-01-FW is 15 A at 8 kHz, compared with 20 A at 4 kHz.
05Which connector carries the motor feedback for HDS02.2-W040N-HA01-01-FW?
Connect the motor-feedback cable to X4 on HDS02.2-W040N-HA01-01-FW; X5 is the motor-power output and X6 is the auxiliary motor connection group.
06Why must HDS02.2-W040N-HA01-01-FW be installed in a closed cabinet?
HDS02.2-W040N-HA01-01-FW has IP10 protection and internal air cooling, so the manual places it inside a closed control cabinet with the specified airflow space.
Automation Component Coordination
Moore AutomationMoore Automation Limited
https://www.mvme.cn/Moore Automation Limited handles industrial automation enquiries by exact manufacturer code and interface version. Analog and bus-based controller configurations remain on separate commercial records.
Quotation data, requested product documentation and delivery communication are coordinated through one named contact.








No related record found