004 power class
DKC10.3-004-3-MGP-01VRS identifies the 4 A basic device and its 100 W controller-power requirement.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS MGP Drive Controllers |
| Item NO. | 2944901 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BOSCH |
| Brand | BOSCH |
| Creation Time | 2026-11-25 |
Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS are ECODRIVE drive controllers with a 300 V nominal DC bus and the MGP multi-interface general-purpose configuration. The 004 and 008 identifiers separate the 4 A and 8 A current classes while the remaining type-code positions retain the same product generation and interface family.
Within DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS, the 01 position identifies the standard design and VRS marks the firmware record supplied with the controller. The firmware identity belongs with the basic-device code because parameter behavior and supported functions depend on both hardware and software.
Both DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS are IP20 devices for control-cabinet installation. Their rated operation is defined for 0 to 40 °C without derating, with documented derating toward 55 °C, and their installation record must preserve the correct current class rather than treating the two labels as interchangeable.
| Specification | DKC10.3-004-3-MGP-01VRS | DKC10.3-008-3-MGP-01VRS |
|---|---|---|
| Brand | Bosch Rexroth | Bosch Rexroth |
| Product Type | MGP drive controller | MGP drive controller |
| Brand Country | Germany | Germany |
| Current class | 4 A | 8 A |
| Nominal DC bus | 300 V DC | 300 V DC |
| Basic-device power requirement | 100 W | 200 W |
| Interface class | Multi-interface general-purpose | Multi-interface general-purpose |
| Design version | 01 standard | 01 standard |
| Firmware designation | VRS | VRS |
| Enclosure protection | IP20 | IP20 |
| Rated ambient temperature | 0 to 40 °C | 0 to 40 °C |
| Derated ambient limit | Up to 55 °C | Up to 55 °C |
| Storage temperature | -20 to 80 °C | -20 to 80 °C |
| Maximum humidity | 90%, non-condensing | 90%, non-condensing |
| Rated installation altitude | Up to 1000 m | Up to 1000 m |
Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS combine power class, interface design and firmware identity into two complete, traceable device records.
DKC10.3-004-3-MGP-01VRS identifies the 4 A basic device and its 100 W controller-power requirement.
DKC10.3-008-3-MGP-01VRS identifies the 8 A basic device and its 200 W controller-power requirement.
MGP, design 01 and VRS remain common, defining the shared interface and software family without erasing the current-class difference.
Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS depend on the cabinet for protection, cooling and environmental control.
The drive controllers require a closed cabinet that prevents access and limits contamination around live circuitry.
Full ratings apply through 40 °C; operation toward 55 °C requires the documented derating and sufficient airflow.
Humidity must remain non-condensing and altitude-related derating is considered above the documented 1000 m reference.
No. Bosch Rexroth DKC10.3-004-3-MGP-01VRS is the 4 A class and DKC10.3-008-3-MGP-01VRS is the 8 A class. Motor data and current limits must remain inside the installed controller rating.
Confirm the full Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS type code, MGP interface family and VRS release expected by the parameter set. Hardware identity alone does not prove software compatibility.
For Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS, compare cabinet inlet temperature with the 40 °C full-rating limit, inspect airflow and measure loading. Apply documented derating before operation near 55 °C.
Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS combine power switching and low-level feedback. Continuous shield bonding and cable separation reduce coupled noise that can appear as feedback or interface faults.
Isolate mains power and wait for the documented discharge interval, then measure the DC bus on Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS. A dark display is not proof that stored bus energy is absent.
Read the complete nameplate and compare the 004 or 008 position, then verify cabinet documentation and motor current. Bosch Rexroth DKC10.3-004-3-MGP-01VRS / DKC10.3-008-3-MGP-01VRS share an interface family but not the same current capacity.