Power boundary
Mains, DC-bus and motor-power terminals carry the energy path without sharing the low-voltage control connector.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bosch Rexroth DKC05.3-040-7-FW Drive Controller |
| Item NO. | 2944900 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BOSCH |
| Brand | BOSCH |
| Creation Time | 2026-11-25 |
Bosch Rexroth DKC05.3-040-7-FW is an ECODRIVE03 drive controller built around a 700 V nominal DC bus and a 40 A current-class power stage. Its front panel groups mains and DC-bus power, motor output, control voltage, motor feedback, brake control and digital interface connections into defined terminal areas.
On DKC05.3-040-7-FW, the 24 V control supply is separated from the power section so control electronics can be checked independently of the motor power path. The device accepts 19.2 to 28.8 V DC at its control input, while the IP20 enclosure is intended for installation inside a closed control cabinet.
The communication side of DKC05.3-040-7-FW provides a CANopen path with CAN_H, CAN_L and shield references. Motor feedback and control connections remain on their designated connectors, allowing the controller to exchange motion commands while the feedback circuit returns the position and motor-state information used by the drive control loop.
| Specification | DKC05.3-040-7-FW |
|---|---|
| Brand | Bosch Rexroth |
| Product Type | ECODRIVE03 drive controller |
| Brand Country | Germany |
| Rated current class | 40 A |
| DC-bus nominal voltage | 700 V DC |
| Control voltage | 19.2–28.8 V DC |
| Maximum control-supply overvoltage | 45 V for 1 ms |
| Control-supply inrush current | 4 A |
| Control-power requirement | 20 W |
| Communication | CANopen |
| CAN signal references | CAN_H, CAN_L and shield |
| Enclosure protection | IP20 |
| Mounting environment | Closed control cabinet |
| Motor interface | Power output with dedicated feedback connector |
| Brake connection | Dedicated holding-brake control path |
The front of Bosch Rexroth DKC05.3-040-7-FW separates energy, feedback and control circuits so each signal family has a distinct physical boundary.
Mains, DC-bus and motor-power terminals carry the energy path without sharing the low-voltage control connector.
The motor-feedback connector returns position and motor data to the controller separately from output power.
Control voltage, brake control and digital connections remain available for cabinet wiring and status handling.
Bosch Rexroth DKC05.3-040-7-FW uses a defined CANopen link rather than treating the fieldbus as an unspecified serial connection.
CAN_H and CAN_L form the differential communication pair between the controller and the CANopen network.
The cable shield is bonded at the assigned connection to control interference around the bus pair.
Network address, baud rate and the controller parameter set must describe the same physical node before cyclic control begins.
Bosch Rexroth DKC05.3-040-7-FW can energize its control electronics from 24 V while the 700 V DC-bus or enable chain is unavailable. Check the control supply, DC-bus state, enable inputs and recorded fault before tracing the motor circuit.
For Bosch Rexroth DKC05.3-040-7-FW, confirm CAN_H and CAN_L polarity, shield bonding, end-of-line termination and the configured node address. A powered controller with reversed bus conductors will not exchange valid CANopen telegrams.
Inspect the dedicated feedback plug on Bosch Rexroth DKC05.3-040-7-FW for bent contacts, shield continuity and cable separation from motor conductors. Then compare the selected motor-feedback type with the connected motor.
Bosch Rexroth DKC05.3-040-7-FW releases the brake only when its control sequence and brake circuit conditions are satisfied. Verify brake voltage at the assigned connector, output timing and the motor-brake coil before changing drive parameters.
Measure inlet air and the temperature rise above Bosch Rexroth DKC05.3-040-7-FW under load, then inspect clearances and airflow. IP20 protection requires a cabinet, but the cabinet must still remove drive losses.
Keep the full Bosch Rexroth DKC05.3-040-7-FW identity, connected motor data, CANopen node settings and the proven parameter backup together. Loading a file from a different current class or motor can create immediate enable and feedback faults.
Moore Automation specializes in sourcing discontinued, obsolete and hard-to-find industrial automation components. Its broad stock and global sourcing network help customers locate parts for established control, drive and monitoring platforms while keeping access to mature product families open.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found