A 1.1 GHz RX3i CPU with 13 MB user memory, two switched Gigabit Ethernet ports and broad protocol support.
01
Product Details
GE IC695CPE310-BHAE is a PACSystems RX3i controller with a 1.1 GHz processor, thirteen megabytes of user memory and thirteen megabytes of nonvolatile flash. It runs ladder diagram, structured text, function block diagram and C applications inside a PAC Machine Edition hardware target.
Two switched Gigabit Ethernet ports on GE IC695CPE310-BHAE carry SRTP, Modbus TCP, Ethernet Global Data, OPC UA and supported PROFINET services. The controller also supports utility protocols including DNP3 Outstation, IEC 61850 client and IEC 60870-5-104 server when configured for those roles.
GE IC695CPE310-BHAE provides up to 32K discrete references in each direction, 32K analog words in each direction and as many as 512 program blocks. USB removable-data support, controller fault tables and compatible energy-pack retention complete the CPU’s runtime and recovery functions.
02
Specification Summary
Specification recordVerified product details
Brand
GE
Model
IC695CPE310-BHAE
Product Name
PACSystems RX3i Controller
Country
Not specified
Processor
1.1 GHz
User Memory
13 MB
Nonvolatile Flash
13 MB
Ethernet Interfaces
Two switched 10/100/1000 ports
Industrial Services
SRTP, Modbus TCP, EGD, OPC UA and PROFINET
Utility Protocols
DNP3, IEC 61850 client and IEC 60870-5-104 server
Programming Languages
Ladder, structured text, function block and C
Program Blocks
Up to 512
Discrete References
32K input and 32K output bits
Analog References
32K input and 32K output words
Operating Temperature
0 to 60 °C
03
Product Functions
GE IC695CPE310-BHAE combines control execution, shared process state, protocol handling and recovery functions in one RX3i CPU.
CONTROL
Coordinate multiple logic forms
Ladder, structured text, function block and C routines execute under one controller scheduler and use the same configured variables. This lets sequencing, calculations and reusable functions cooperate without separate data gateways between program languages.
DATA
Maintain one operating state
Reference tables and symbolic variables hold field values, calculated results and exchanged data for the running application. Retained content and the nonvolatile controller image remain distinct so a restart can restore the intended portions of that state.
SERVICES
Serve different data consumers
Peer exchange, supervisory access, utility communication and information-model clients reach controller data through independent protocol roles. Each service has its own endpoint and mapping even though the underlying variables belong to the same application.
04
Configuration and Programming
The complete target binds logic, module layout, network roles and recovery behavior to the controller hardware.
TARGET
Describe the RX3i system
The PAC Machine Edition target defines the universal-backplane modules, reference allocation and CPU properties that are checked when the controller starts. A mismatch is therefore evaluated against both the downloaded rack description and the physical backplane.
PROTOCOLS
Configure each network role
OPC UA, EGD, Modbus TCP and utility protocols use independent parameters, so their endpoints, data maps and security settings are maintained separately. Enabling one service does not automatically establish addressing, trust or data exchange for another.
RECOVERY
Preserve project and retained data
Flash storage, removable media and the compatible energy-pack path provide different recovery mechanisms; the project defines which data each mechanism protects. Keeping those roles distinct prevents a controller image from being mistaken for a live retained-state record.
05
Frequently Asked Questions
How can a SYS FLT on GE IC695CPE310-BHAE be preserved for analysis?
For GE IC695CPE310-BHAE, capture the controller and I/O fault tables, LED pattern, running project checksum and network state before clearing or power-cycling.
Why can GE IC695CPE310-BHAE start with a hardware mismatch?
GE IC695CPE310-BHAE compares the downloaded RX3i configuration with the installed backplane; verify slot order, module catalog numbers and project target before clearing the mismatch.
How should GE IC695CPE310-BHAE Ethernet ports be connected?
Document the two GE IC695CPE310-BHAE switched ports as one controller interface, including both cable destinations, IP plan and any line-topology recovery expectations.
Why can a DNP3 session fail while SRTP works on GE IC695CPE310-BHAE?
GE IC695CPE310-BHAE services have separate roles and parameters; check DNP3 enablement, addressing, data map, event classes and network filtering independently of SRTP.
What should be checked if GE IC695CPE310-BHAE loses retained values?
For GE IC695CPE310-BHAE, verify the retained-variable definitions, energy-pack state, shutdown sequence, flash operation and the startup source used after power restoration.
What must be archived for GE IC695CPE310-BHAE recovery?
Archive the GE IC695CPE310-BHAE target, logic, hardware map, network and protocol settings, firmware identity, retained-value plan and removable-media contents.
Moore Automation supplies a broad range of industrial control and monitoring brands for established plants. A GE IC695CPE310-BHAE enquiry can remain tied to the requested CPU while related I/O, drive, HMI and condition-monitoring items are coordinated under the same commercial discussion.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found