SIL 2 controller with expanded safety memory
Allen-Bradley 5069-L310ERS2 Compact GuardLogix 5380 SIL 2 Safety Controller
1 MB standard memory, 0.5 MB safety memory and 24 EtherNet/IP nodes.
Product Description
Combining conventional machine logic with a certified safety task, the Allen-Bradley 5069-L310ERS2 allocates 1 MB to standard control and 0.5 MB to safety content.
Its local bank accepts eight Compact 5000 I/O modules, and the EtherNet/IP configuration can include up to 24 nodes. Dual embedded ports support the network arrangements used across CompactLogix 5380 systems.
A 5069-L310ERS2 project should keep device ownership, safety connections and standard communications explicit so commissioning changes do not blur the boundary between control and protection.
Technical Specifications
| Technical Item | 5069-L310ERS2 |
|---|---|
| Brand | Allen-Bradley |
| Product Type | Compact GuardLogix 5380 SIL 2 controller |
| Brand Country | United States |
| Standard Memory | 1 MB |
| Safety Memory | 0.5 MB |
| Local I/O Modules | 8 maximum |
| EtherNet/IP Nodes | 24 maximum |
| Safety Rating | SIL 2; PLd; Category 3 |
| Ethernet Ports | 2 × 10/100/1000 Mb/s |
| USB Port | USB 2.0 Type B; 12 Mb/s |
| MOD Power | 18…32 V DC SELV/PELV; 475 mA maximum |
| Thermal Dissipation | 30.9 BTU/hr maximum |
| Relative Humidity | 5…95%, noncondensing |
Standard and Safety Project Integration
Develop both control domains in one Logix project
- Standard tasks handle machine sequencing while the safety task owns validated protective logic.
- Use mapped or permitted tag exchange deliberately and prevent standard routines from becoming an undocumented safety dependency.
- Safety signatures identify a validated safety application state and must be managed whenever protected content changes.
- Allocate code and tags against the separate 1 MB standard and 0.5 MB safety capacities.
Controller System Layout
Place controller, local I/O and remote safety devices on defined paths
- The system diagram separates the local Compact 5000 bank from EtherNet/IP-connected HMIs, drives and I/O adapters.
- Keep the local row within eight modules and the total configured network within 24 nodes.
- Choose linear, DLR or Dual-IP topology based on failure recovery and traffic separation requirements.
- Document every safety I/O path so replacement and troubleshooting preserve the validated architecture.
Frequently Asked Questions
Why can 5069-L310ERS2 run standard logic while the safety task remains faulted?
Standard and safety execution are supervised separately, so a safety fault can inhibit the protective application without stopping every standard routine. Diagnose the safety status and place the machine in a safe condition before attempting a reset.
Can 5069-L310ERS2 safety tags be changed from an HMI like ordinary setpoints?
Only design-approved, permitted interactions should be exposed, and they must not bypass the validated safety function. Treat safety-related operator input as part of the risk assessment and validation rather than ordinary process data.
What must be preserved when replacing 5069-L310ERS2?
Record firmware, project revision, safety network numbers, ownership and the valid safety signature. After replacement, follow the controlled download and verification procedure and test the complete safety function.
Why does 5069-L310ERS2 report a safety I/O connection mismatch?
Compare the configured device catalog, revision, electronic keying, safety network identity and connection parameters with the installed module. A standard I/O connection can appear healthy while the safety connection is rejected.
Can the USB port of 5069-L310ERS2 remain connected to a service computer?
The USB 2.0 Type-B port is intended for temporary local programming, not permanent production communication. Remove the cable after attended maintenance and use the Ethernet design for normal operation.
How should growth be planned around the 24-node limit of 5069-L310ERS2?
Reserve node capacity for anticipated safety adapters, drives, remote I/O and supervisory devices before commissioning. A later device addition may require architecture changes even when memory remains available.
Dedicated Account Management
Moore Automation
One contact from enquiry through order communication
Moore Automation assigns an account manager to maintain continuity across product details, quotations and progress updates. Buyers do not need to restart the same model discussion at each commercial step.
Send the complete part number and quantity so the requested variant remains clear from enquiry through quotation.
Recommended Products
- SMC CDQMA40-25
- SICK WT12L-2B530
- Weidmüller 1709460000
- Baumüller BUM62T-100/130-54-M-038
- Bosch 044437-201401
- Indramat KDA3.3-150-3-A00-W
- Siemens 3RU2116-1GB0
- ABB 2CDG110027R0011
- Allen-Bradley 20-750-ML1-C1K4D1K3
- Honeywell P8000A0016G
- Festo 530411
- Schneider METSEDM1310
- WAGO 753-647
- B&R 8BVI0110HWSS.000-1
- Beckhoff KL3061
- Rexroth 5610214710
- GE DP65
- Lenze MDFKABS100-22
- Legrand 077691L
- Brady PTL-30-428-CALI
- ifm IF6074
- SEW 8221049.16
- SMC SFD102-F02
- SICK WS9-3D3430
- Weidmüller 1029800000
- Baumüller BUM62T-100/130-54-M-011-01
- Bosch 041889-109401
- KEB DL90S4
- Siemens 6ES7972-0BA60-0XA0
- ABB 68870089
- Allen-Bradley 20-750-MI2-C585D545
- Honeywell XF521
- Festo DSBC-63-200-PPVA-N3
- Schneider U202SPM_RJ_B00
- WAGO 750-610
- B&R 8BVI0014HWSS.000-1
- Beckhoff EK1100
- Rexroth R168120133
- GE CR104PBG91G3
- Lenze MDSKABS090-22
- Legrand 050027
- Brady PTL-11-427
- ifm E12205
- SEW 8221049.10
- SMC MXS8-20
- SICK WLL12-B5481
- Weidmüller 1709490000
- Baumüller BUM62T-100/130-54-M-039
- Bosch 041523-110401
- Siemens AQR2531ANW
- ABB 6120/12-101-500
- Allen-Bradley 100-D630ED11
- Honeywell S7810A1009
- Festo DGE-KG-40-ZR
- Schneider A3031WBP
- WAGO 750-430
- B&R 5PC600.SX05-01
- Beckhoff LC5200
- Rexroth R162322220
- GE RL4RD022TD
Contact Us
Send the complete part number and quantity for a quotation.









No related record found