Allen-Bradley · PanelView Plus 7 Standard
Allen-Bradley 2711P-T9W21D8S PanelView Plus 7 Standard 9 Terminal
9-inch WVGA single-port touch terminal for PanelView Plus 7 Standard applications.
System Overview
Allen-Bradley 2711P-T9W21D8S is a 9-inch widescreen touch terminal in the PanelView Plus 7 Standard family. Its 196 by 118 mm viewing area uses an 800 x 480 WVGA, 18-bit colour graphics format with a 5:3 aspect ratio.
The terminal presents and accepts information through analogue resistive touch, then runs a FactoryTalk View Machine Edition Station application created with FactoryTalk View Studio Machine Edition. The operating system is Windows CE, and the published terminal resources include 512 MB RAM, 512 MB storage and 80 MB nonvolatile storage for applications.
2711P-T9W21D8S is the 21-suffix, single-Ethernet-port configuration. The port is 10/100Base-T Auto MDI/MDI-X with IEEE 1588 support; it is not the two-port 22 version intended for star, linear and DLR topology.
Panel space is controlled by the published approximate 162 by 252 mm cutout and 190 by 280 by 56.5 mm terminal dimensions. The product's 24 V DC nominal input remains a separate power-path consideration from the Ethernet connection.
Configuration Reference
| Technical item | 2711P-T9W21D8S |
|---|---|
| Brand | Allen-Bradley |
| Product type | PanelView Plus 7 Standard touch terminal |
| Display | 9 in. wide color TFT LCD |
| Resolution | 800 x 480 WVGA, 18-bit graphics |
| Aspect ratio | 5:3 |
| Viewing area | 196 x 118 mm |
| Ethernet | One 10/100Base-T Auto MDI/MDI-X port |
| Timing support | IEEE 1588 |
| Memory | 512 MB RAM; 512 MB storage; 80 MB application storage |
| Power | 24 V DC nominal, 18 to 30 V DC; 50 W maximum |
| Cutout | 162 x 252 mm, approximate |
| Software | FactoryTalk View Studio ME 8.0 or later |
Single-port network boundary
Connection role
Single-port network boundary
The 21 marker in 2711P-T9W21D8S corresponds to one 10/100Base-T Auto MDI/MDI-X Ethernet port with IEEE 1588 support. It is a single-port terminal configuration rather than a two-port DLR device.
That distinction matters when a panel contains two network leads. The port count must be checked from the full catalog number rather than inferred from the 9-inch display.
- One Ethernet port
- IEEE 1588 support
- 21-suffix configuration
WVGA panel-fit reference
Display and mounting
WVGA panel-fit reference
The 9-inch unit combines 800 x 480 WVGA graphics with a 196 by 118 mm viewing area. Its approximate 162 by 252 mm cutout is different from both the 5.7-inch and 10.4-inch PanelView Plus 7 Standard terminals.
The official technical figure retains the family front and single-port bottom views, together with the size table used for the terminal envelope.
- 9 in. wide display
- 162 x 252 mm cutout
- Official single-port illustration
Frequently Asked Questions
A site wants to pass a ring through a 9-inch HMI; why does its single-port configuration stop that network assumption (2711P-T9W21D8S)?
The published configuration confirms that 2711P-T9W21D8S has one Ethernet port with IEEE 1588 support; the two-port DLR arrangement belongs to the 22-suffix configuration instead.
When a replacement must preserve the operator's field of view, which 5:3 WVGA dimensions define this screen (2711P-T9W21D8S)?
For a replacement decision, the listed data shows that 2711P-T9W21D8S uses a 9-inch 5:3 display with 800 x 480 WVGA resolution and a 196 x 118 mm viewing area.
A panel shop is preparing a spare door; what mechanical envelope must it reserve for this 9-inch terminal (2711P-T9W21D8S)?
The installation check is resolved by the fact that 2711P-T9W21D8S uses an approximate 162 x 252 mm cutout and an approximate 190 x 280 x 56.5 mm envelope.
For a terminal project that must be edited and then run on the machine, which two FactoryTalk environments serve those jobs (2711P-T9W21D8S)?
In the official technical record, 2711P-T9W21D8S is configured with FactoryTalk View Studio Machine Edition and runs FactoryTalk View Machine Edition Station.
When the cabinet supply is near its loading limit, which input range and maximum power figure should be used in the calculation (2711P-T9W21D8S)?
The relevant hardware boundary is that 2711P-T9W21D8S has a 24 V DC nominal, 18 to 30 V DC nonisolated input and a 50 W maximum power figure.
A maintenance team needs an offline application copy; what internal and removable memory provisions are listed (2711P-T9W21D8S)?
For engineering selection, the documented result is that 2711P-T9W21D8S has 512 MB RAM, 512 MB storage, 80 MB application storage and an SD card slot for application files.
Moore Automation
Moore Automation
Responsive commercial support
Moore Automation provides a defined contact route for industrial automation component enquiries. A complete part reference supports a clearer response about the requested item.
- Original products
- Fast delivery
- 1-year warranty
- 12-hour online response
Related Product List
- Siemens 3VA1110-5EF42-0AA0
- Omron E5EN-HAA2HBM-500
- Mitsubishi Electric FX-16MT-ESS
- Yaskawa SGD7S-R90A00A002
- Danfoss 131B5134
- Allen-Bradley 150-F85NBD
- GE IS200EPDMG1A
- B&R 6PPT50.101E-10B
- B&R 8I64S200018.00X-1
- B&R AB7000
- B&R 8EI4X5HWS10.0500-1
- B&R X20cSO4110
- B&R X20BC8083
- B&R X20IF1072
- B&R X20BC00E3
- B&R X20AI2622
- B&R 7AO352.7
- B&R AO352
- B&R DO138
- B&R 7D0138.70
- B&R 7DO138.70
- B&R 7AT324.70-1
- B&R DO139
- B&R 7D0139.70
- B&R 7DO139.70
- B&R CI410
- B&R 7CI410.70-1
- B&R IF361
- B&R AI351
- B&R 7IF361.70-1
- B&R 7AI351.70
- B&R 41F370.7
- B&R 7RM351.70
- B&R IF321
- B&R 7IF321.7
- B&R AI774
- B&R 7AI774.70
- B&R AT664
- B&R AI294
- B&R 7AI294.7
- B&R 3IF762.9
- B&R IF762
- B&R AT352
- B&R 7AT352.70
- B&R AI354
- B&R 7AI354.70
- B&R 7AT352.7
- B&R X67SI8103
- B&R 8AC110.60-3
- B&R AB7800-F
- B&R AB7834-F
- B&R AB7699-F
- B&R 5PP320.0571-39
- B&R 5AP920.1906-K07
- B&R A0352
- B&R 7R0352.70
- B&R 7RO352.70
- B&R 7AO352.70
- B&R D0135
- B&R DO135









No related record found