Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer

Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer Item NO.: 2945607

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer
Item NO. 2945607
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-27

Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer | Moore Automation
YOKOGAWA
INDUSTRIAL · CONTROL
Flameproof Paramagnetic Oxygen Analyzer

Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer

Continuous oxygen measurement in flammable process gas with nitrogen auxiliary gas

01 / Product

Equipment Profile

Selective oxygen measurement in combustible process mixtures is the defining purpose of Yokogawa MG8E-5AWNS-E. The analyzer uses the paramagnetic property of oxygen and a magnetic proportional-flow cell, allowing oxygen concentration to be measured without placing a moving sensor element in the sample stream.

Inside MG8E-5AWNS-E, clean nitrogen auxiliary gas is divided into two streams around the magnetic cell. Oxygen in the sample changes the flow balance between those streams; thermistors detect that difference and the electronics convert it into the displayed concentration and isolated 4-20 mA output.

The configured MG8E-5AWNS-E record covers a 0-5 to 25 vol% oxygen range, standard cell material, nitrogen auxiliary gas and a 35 ml/min auxiliary-flow arrangement. Its flameproof Ex d IIB T4 construction, 100-115 VAC supply and English interface belong to the complete order identity.

Click for clear original
02 / Data

Operating Data

Technical Item MG8E-5AWNS-E
Brand Yokogawa
Product Type Flameproof paramagnetic oxygen analyzer
Brand Country Japan
Measurement Object Oxygen concentration in gaseous mixtures
Measurement Range 0-5 to 25 vol% O2
Measurement System Magnetic proportional-flow paramagnetic system
Analog Output Isolated 4-20 mA DC; 550 ohm maximum load
Response Time 90% response within 3 seconds
Repeatability / Linearity Within +/-1% of span
Sample Gas Flow 300-800 ml/min; 600 ml/min standard
Analyzer Inlet Pressure Approximately 7 kPa
Sample Temperature 0 to 50 deg C
Auxiliary Gas Nitrogen, 350-500 kPa; 35 ml/min
Power / Construction 100-115 VAC, 50/60 Hz; flameproof Ex d IIB T4
03 / Sensor Cell

Magnetic Proportional-Flow Measurement

Oxygen-specific force

A balanced auxiliary-gas path converts oxygen attraction into an electrical signal.

MG8E-5AWNS-E does not expose the measuring thermistors directly to the process gas. Two auxiliary-gas streams meet the sample inside the ring-shaped sensor cell, and oxygen drawn toward the magnetic field changes one stream relative to the other.

A

Thermistor bridge

The paired thermistors in MG8E-5AWNS-E sense the differential flow instead of measuring oxygen by a consumable electrochemical reaction.

B

Background compensation

Cell-angle adjustment in MG8E-5AWNS-E compensates the density-related influence of a defined background gas or gas mixture.

04 / Gas Paths

Sample, Auxiliary-Gas and Calibration Paths

Sample path

A regulated 300-800 ml/min sample enters MG8E-5AWNS-E at approximately 7 kPa and leaves through the common gas outlet.

Nitrogen path

Clean nitrogen at 350-500 kPa feeds the protected sensor-cell path of MG8E-5AWNS-E at the configured 35 ml/min flow.

Calibration path

Zero gas and span gas can be switched through MG8E-5AWNS-E for manual, semiautomatic or programmed automatic calibration.

05 / Answers

Purchasing Questions

Why should nitrogen flow be established before sample gas reaches MG8E-5AWNS-E?

The protected measuring cell of MG8E-5AWNS-E depends on clean nitrogen auxiliary gas to isolate the thermistors from the process mixture and establish the balanced flow reference. Loss of that flow is therefore an operating fault, not a minor flow variation.

What sample-flow window keeps MG8E-5AWNS-E inside its stated operating conditions?

MG8E-5AWNS-E is specified for 300-800 ml/min, with 600 ml/min as the standard setting. The inlet pressure is approximately 7 kPa, so the sampling system must regulate both flow and pressure rather than forcing plant pressure into the analyzer.

Can MG8E-5AWNS-E measure oxygen when the process mixture is flammable?

Yes. MG8E-5AWNS-E is the flameproof MG8E construction and is identified as Ex d IIB T4. The installed wiring, cable entries and sampling system must still preserve the certified enclosure and site classification.

How quickly can MG8E-5AWNS-E show a changing oxygen concentration?

The documented response of MG8E-5AWNS-E reaches 90% within three seconds at the analyzer. Sampling-line volume, filters and conditioning equipment can add transport delay before the gas reaches the cell.

Which calibration gases are appropriate for MG8E-5AWNS-E?

MG8E-5AWNS-E uses nitrogen as zero gas and a known oxygen-in-nitrogen mixture, or dry instrument air where appropriate, as span gas. The entered concentration must match the cylinder value used for the calibration.

What does the 0-5 to 25 vol% range statement mean for MG8E-5AWNS-E?

MG8E-5AWNS-E supports configured oxygen ranges whose span lies from 5 to 25 vol% O2. It is not a 0-100% analyzer record, so the selected output range must stay within that order-code boundary.

06 / Moore

Analyzer Documentation Desk

www.mvme.cn

Moore Automation

https://www.mvme.cn/

Moore Automation keeps analyzer identity, available technical documents and destination records aligned for Yokogawa MG8E-5AWNS-E. Specialized process-instrumentation requests follow a single communication chain, preserving the full configuration while documents and logistics are coordinated.

Identity reviewComplete analyzer code retained
Document alignmentAvailable technical records coordinated