Product Name Eaton MTL831C Analog Transmitter
Item NO. 2945606
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category OTHER PRODUCTS
Brand OTHER PRODUCTS
Creation Time 2026-11-27

Eaton MTL831C Analog Transmitter | Moore Automation
EATON
INDUSTRIAL · CONTROL
Analog Transmitter

Eaton MTL831C Analog Transmitter

Sixteen-input hazardous-area multiplexer for the MTL830C data highway

01 / Product

Model Summary

Up to sixteen field measurements enter Eaton MTL831C, an intrinsically safe analog transmitter in the MTL830C temperature multiplexer system. Its input channels can mix thermocouples, millivolt sources, 2-, 3- or 4-wire RTDs and potentiometers in one transmitter.

A single shielded twisted-pair data highway carries both signal data and operating power for MTL831C. At the safe-area end, an MTL838C receiver converts the channel data and status for the control system; hazardous-area installations place an MTL5553 isolator/power supply in the path.

One receiver can serve one or two MTL831C transmitters, yielding as many as 32 inputs on the shared highway. The first transmitter uses address 1, while a jumper between A and S assigns address 2 to the second unit so their channel groups remain distinct.

Click for clear original
02 / Data

Technical Reference

Technical Item MTL831C
Brand Eaton
Product Type Intrinsically safe analog transmitter / multiplexer
Brand Country United Kingdom
Input Channels 16
Supported Inputs Thermocouple, millivolt, 2/3/4-wire RTD and potentiometer
Data Highway Single shielded twisted pair carrying signal and power
Receiver and IS Interface MTL838C receiver; MTL5553 isolator / power supply for IS service
Highway Capacity 1 or 2 transmitters; up to 32 inputs
Typical Highway Distance 1 km IS; 2 km non-IS, cable and noise dependent
Hazardous Location Suitable for Zone 0 when installed to the certified system rules
Ambient Temperature -40 to +70 °C
Mounting 35 mm T-section DIN rail on a vertical plane
Status Indication POWER and ERROR LEDs
Address Selection Open A-S for address 1; jumper A-S for address 2
03 / Inputs

Sixteen-Channel Input Multiplexing

Mixed sensor population

Different temperature and millivolt sources can share the same transmitter without sharing channel wiring.

MTL831C converts sixteen individually wired sensor channels into one digital data-highway stream. Channel configuration determines thermocouple, millivolt, RTD or potentiometer behavior, allowing a mixed instrument population in one hazardous-area transmitter.

A

RTD conductor choice

Each RTD channel on MTL831C is configured for its 2-, 3- or 4-wire connection so lead resistance is handled by the intended measurement mode.

B

Mixed input set

Thermocouple and RTD channels may coexist on MTL831C because the sensor type is assigned per channel rather than per transmitter.

04 / Highway

Data Highway Addressing and Reach

Power and data pair

The shielded twisted pair connected to MTL831C carries both its operating power and the multiplexed channel data.

Second transmitter

A jumper between A and S assigns address 2 to a second MTL831C, separating channels 17-32 at the receiver.

Distance boundary

The typical reach for MTL831C is 1 km in intrinsically safe service and 2 km in non-IS service, subject to cable quality and interference.

05 / Answers

User Questions

Can MTL831C mix thermocouple and RTD channels in one unit?

Yes. MTL831C configures each of its sixteen inputs independently for thermocouple, millivolt, RTD or potentiometer service. The wiring at each terminal group must match the selected channel mode.

How is a second MTL831C distinguished on the same data highway?

A jumper between the A and S address terminals sets the second MTL831C to address 2. Leaving those pins open sets address 1, so both transmitters must not use the same state.

What equipment receives the data from MTL831C?

The normal receiver for MTL831C is MTL838C, which presents the measurements and status to the control system. In an intrinsically safe installation, MTL5553 provides the required isolated power interface.

Why must the data-highway polarity be checked on MTL831C?

The same pair that carries data also powers MTL831C. Reversing the plus and minus terminals prevents the intended power and communication path from operating correctly.

How far can the MTL831C data highway run?

Typical guidance for MTL831C is up to 1 km in intrinsically safe applications and 2 km in non-IS applications. Cable characteristics and electrical interference can reduce those practical distances.

Where should an MTL831C be mounted to maintain accuracy?

MTL831C mounts on a vertical plane using vertical or horizontal 35 mm T-section DIN rail. It should be separated from heat sources that create a temperature gradient across the transmitter.

06 / Moore

International Service Coverage

www.mvme.cn

Moore Automation

https://www.mvme.cn/

Moore Automation supports international industrial teams with product coordination for Eaton MTL831C. Global destination handling, secure packing communication and responsive customer support are kept in one service channel so product and delivery records remain consistent.

Global serviceInternational destinations supported
Secure coordinationPacking and records aligned
Responsive contactQuestions handled promptly
08 / Contact

Request Information

Moore AutomationRequest Information
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.