Emerson PR6423/011-040 8 mm Eddy Current Sensor
Armored M10 sensor with adapter plug, 10 m cable and LEMO termination
Equipment Profile
A 2 mm linear measurement window defines Emerson PR6423/011-040, an 8 mm eddy-current sensor for non-contact shaft displacement, position, eccentricity and speed measurement. Its nominal starting gap is 0.5 mm and its standard scale factor is 8 V/mm over the stated temperature reference.
Order code PR6423/011-040 identifies an M10×1 case with armored cable, a 35 mm sleeve, an adapter plug, 10 m total cable and a LEMO termination. These mechanical fields control mounting depth, routing radius and the interface presented to the connected converter.
Environmental construction on PR6423/011-040 combines an IP66 sensor, PEEK tip, stainless-steel case, PTFE cable and nickel-plated brass connector. The sensor and first metre of cable can operate from -35 to +180 °C, while the remaining cable and connector are limited to +150 °C.
Operating Data
| Technical Item | PR6423/011-040 |
|---|---|
| Brand | Emerson |
| Product Type | 8 mm eddy-current sensor |
| Brand Country | United States |
| Case Thread | M10×1 |
| Armor and Sleeve | Armored cable; 35 mm sleeve |
| Adapter and Cable End | Adapter plug; LEMO termination |
| Total Cable Length | 10 m |
| Linear Measurement Range | 2 mm |
| Initial Air Gap | 0.5 mm |
| Incremental Scale Factor | 8 V/mm ±5% at 0 to 45 °C |
| Linearity Deviation | ±0.025 mm at 0 to 45 °C |
| Protection Class | IP66 |
| Operating Temperature | Sensor + 1 m cable: -35 to +180 °C; cable/connector: -35 to +150 °C |
| Minimum Shaft Diameter | 25 mm |
Probe Gap and Linear Window
The initial gap places the shaft signal inside the documented linear voltage window.
PR6423/011-040 begins with a nominal 0.5 mm air gap and provides a 2 mm linear measurement range. The connected converter interprets displacement from the sensor voltage, so the mechanical setup and electrical scale factor are treated as one measurement chain.
Scale reference
The 8 V/mm incremental scale factor of PR6423/011-040 is stated at 0 to 45 °C against the standard 42CrMo4 target.
Target geometry
A shaft diameter of at least 25 mm preserves the documented target geometry for PR6423/011-040.
Cable and Connector Arrangement
The armored section of PR6423/011-040 uses a 6 mm cable diameter and a 35 mm minimum bend radius.
The adapter plug for PR6423/011-040 is located after the first metre of sensor cable.
A male 11 mm LEMO connector terminates the 10 m cable assembly of PR6423/011-040.
Purchasing Questions
How should the 0.5 mm initial gap on PR6423/011-040 be interpreted?
The 0.5 mm value places PR6423/011-040 at the beginning of its documented 2 mm linear range. It is a mechanical reference for setup, not the full measurable displacement.
What target material is the scale factor of PR6423/011-040 based on?
PR6423/011-040 is specified against ferromagnetic 42CrMo4 steel. A different alloy or surface geometry can change the electrical response and should be evaluated separately.
Why does PR6423/011-040 have two temperature limits?
The sensor head and first metre of PR6423/011-040 are rated to +180 °C, but the remaining cable and connector are rated to +150 °C. Routing must respect the lower limit at the connector side.
What minimum bend radius protects the armored cable on PR6423/011-040?
The armored 6 mm cable of PR6423/011-040 requires a minimum 35 mm bend radius. Tighter routing can stress the armor and the conductors beneath it.
Can PR6423/011-040 be used against a shaft smaller than 25 mm?
The documented minimum shaft diameter for PR6423/011-040 is 25 mm. A smaller target is outside the geometry used for the stated scale and linearity.
Which termination should be present at the end of PR6423/011-040?
PR6423/011-040 ends in a male LEMO connector after the 10 m cable path. An open cable end would represent a different final order-code position.
Fast Response and Traceability
Moore Automation
https://www.mvme.cn/Moore Automation combines rapid acknowledgement with exact record control for Emerson PR6423/011-040. A 24-hour response target, lead-time communication and shipment status updates are managed without shortening or separating the complete sensor suffix.
Selected Products
| Control & Process | PLC & I/O | Monitoring & Network | Drives & Power |
|---|---|---|---|
| 01Honeywell CC-GDOL11 | 16ABB PM858K01 | 31Yokogawa ASR133 | 46Yokogawa ATA4S |
| 02Yokogawa AAP849 | 17Allen-Bradley 1756-OF8 | 32GE IC600BF942 | 47GE IC600LX648 |
| 03GE IC600BF914 | 18Emerson KJ3203X1-BA1 | 33ABB PM862K01 | 48ABB PM865K01 |
| 04ABB PM856K01 | 19Honeywell CC-GDIL21 | 34Allen-Bradley 1756-EN2TR | 49Allen-Bradley 1756-CN2R |
| 05Allen-Bradley 1756-OB16E | 20Yokogawa ASI533 | 35Emerson KJ3222X1-BA1 | 50Emerson KJ3241X1-BA1 |
| 06Emerson KJ3201X1-BA1 | 21GE IC600BF940 | 36Yokogawa ASD143 | 51Yokogawa ATA4D |
| 07Honeywell CC-GAIX21 | 22ABB PM860K01 | 37GE IC600BF948 | 52GE IC600LX680 |
| 08Yokogawa ADR541 | 23Allen-Bradley 1756-OW16I | 38ABB PM863K01 | 53ABB PM866K01 |
| 09GE IC600BF915 | 24Emerson KJ3204X1-BA1 | 39Allen-Bradley 1756-EN3TR | 54Allen-Bradley 1756-DNB |
| 10ABB PM857K01 | 25Honeywell CC-GDOL21 | 40Emerson KJ3222X1-BA2 | 55Emerson VE4001S2T1B1 |
| 11Allen-Bradley 1756-OB32 | 26Yokogawa AST143 | 41Yokogawa ASD533 | 56Yokogawa ATK4A |
| 12Emerson KJ3202X1-BA1 | 27GE IC600BF941 | 42GE IC600LX624 | 57GE IC600PM500 |
| 13Honeywell CC-GAOX21 | 28ABB PM861AK01 | 43ABB PM864AK01 | 58ABB PM867K01 |
| 14Yokogawa ASI133 | 29Allen-Bradley 1756-EN2T | 44Allen-Bradley 1756-EN4TR | 59Allen-Bradley 1756-DHRIO |
| 15GE IC600BF923 | 30Emerson KJ3221X1-BA1 | 45Emerson KJ3222X1-EA1 | 60Emerson VE4002S1T1B1 |







No related record found