Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>EMERSON>Emerson PR6423/011-040 8 mm Eddy Current Sensor
Emerson PR6423/011-040 8 mm Eddy Current Sensor

Emerson PR6423/011-040 8 mm Eddy Current Sensor Item NO.: 2945602

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Emerson PR6423/011-040 8 mm Eddy Current Sensor
Item NO. 2945602
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category EMERSON
Brand EMERSON
Creation Time 2026-11-27

Emerson PR6423/011-040 8 mm Eddy Current Sensor | Moore Automation
EMERSON
INDUSTRIAL · CONTROL
8 mm Eddy Current Sensor

Emerson PR6423/011-040 8 mm Eddy Current Sensor

Armored M10 sensor with adapter plug, 10 m cable and LEMO termination

01 / Product

Equipment Profile

A 2 mm linear measurement window defines Emerson PR6423/011-040, an 8 mm eddy-current sensor for non-contact shaft displacement, position, eccentricity and speed measurement. Its nominal starting gap is 0.5 mm and its standard scale factor is 8 V/mm over the stated temperature reference.

Order code PR6423/011-040 identifies an M10×1 case with armored cable, a 35 mm sleeve, an adapter plug, 10 m total cable and a LEMO termination. These mechanical fields control mounting depth, routing radius and the interface presented to the connected converter.

Environmental construction on PR6423/011-040 combines an IP66 sensor, PEEK tip, stainless-steel case, PTFE cable and nickel-plated brass connector. The sensor and first metre of cable can operate from -35 to +180 °C, while the remaining cable and connector are limited to +150 °C.

Click for clear original
02 / Data

Operating Data

Technical Item PR6423/011-040
Brand Emerson
Product Type 8 mm eddy-current sensor
Brand Country United States
Case Thread M10×1
Armor and Sleeve Armored cable; 35 mm sleeve
Adapter and Cable End Adapter plug; LEMO termination
Total Cable Length 10 m
Linear Measurement Range 2 mm
Initial Air Gap 0.5 mm
Incremental Scale Factor 8 V/mm ±5% at 0 to 45 °C
Linearity Deviation ±0.025 mm at 0 to 45 °C
Protection Class IP66
Operating Temperature Sensor + 1 m cable: -35 to +180 °C; cable/connector: -35 to +150 °C
Minimum Shaft Diameter 25 mm
03 / Measurement

Probe Gap and Linear Window

Two-millimetre range

The initial gap places the shaft signal inside the documented linear voltage window.

PR6423/011-040 begins with a nominal 0.5 mm air gap and provides a 2 mm linear measurement range. The connected converter interprets displacement from the sensor voltage, so the mechanical setup and electrical scale factor are treated as one measurement chain.

A

Scale reference

The 8 V/mm incremental scale factor of PR6423/011-040 is stated at 0 to 45 °C against the standard 42CrMo4 target.

B

Target geometry

A shaft diameter of at least 25 mm preserves the documented target geometry for PR6423/011-040.

04 / Assembly

Cable and Connector Arrangement

Armored lead

The armored section of PR6423/011-040 uses a 6 mm cable diameter and a 35 mm minimum bend radius.

Adapter position

The adapter plug for PR6423/011-040 is located after the first metre of sensor cable.

LEMO endpoint

A male 11 mm LEMO connector terminates the 10 m cable assembly of PR6423/011-040.

05 / Answers

Purchasing Questions

How should the 0.5 mm initial gap on PR6423/011-040 be interpreted?

The 0.5 mm value places PR6423/011-040 at the beginning of its documented 2 mm linear range. It is a mechanical reference for setup, not the full measurable displacement.

What target material is the scale factor of PR6423/011-040 based on?

PR6423/011-040 is specified against ferromagnetic 42CrMo4 steel. A different alloy or surface geometry can change the electrical response and should be evaluated separately.

Why does PR6423/011-040 have two temperature limits?

The sensor head and first metre of PR6423/011-040 are rated to +180 °C, but the remaining cable and connector are rated to +150 °C. Routing must respect the lower limit at the connector side.

What minimum bend radius protects the armored cable on PR6423/011-040?

The armored 6 mm cable of PR6423/011-040 requires a minimum 35 mm bend radius. Tighter routing can stress the armor and the conductors beneath it.

Can PR6423/011-040 be used against a shaft smaller than 25 mm?

The documented minimum shaft diameter for PR6423/011-040 is 25 mm. A smaller target is outside the geometry used for the stated scale and linearity.

Which termination should be present at the end of PR6423/011-040?

PR6423/011-040 ends in a male LEMO connector after the 10 m cable path. An open cable end would represent a different final order-code position.

06 / Moore

Fast Response and Traceability

www.mvme.cn

Moore Automation

https://www.mvme.cn/

Moore Automation combines rapid acknowledgement with exact record control for Emerson PR6423/011-040. A 24-hour response target, lead-time communication and shipment status updates are managed without shortening or separating the complete sensor suffix.

24-hour responsePrompt acknowledgement
Fast delivery deskLead-time communication
Traceable identityFull sensor code retained
08 / Contact

Commercial Enquiry

Moore AutomationCommercial Enquiry
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.