Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa AAV141-S53/K4A00 G3 16-Channel 1-5 V Analog Input Module
Yokogawa AAV141-S53/K4A00 G3 16-Channel 1-5 V Analog Input Module

Yokogawa AAV141-S53/K4A00 G3 16-Channel 1-5 V Analog Input Module Item NO.: 2932060

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa AAV141-S53/K4A00 G3 16-Channel 1-5 V Analog Input Module
Item NO. 2932060
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-12

Yokogawa AAV141-S53/K4A00 | G3 16-Channel 1-5 V Analog Input Module
Yokogawa · CENTUM VP FIO

Yokogawa AAV141-S53/K4A00 G3 16-Channel 1-5 V Analog Input Module

Exact model and suffix configuration
01

Product Information

Yokogawa AAV141-S53/K4A00 is a 16-channel non-isolated differential 1-5 V input module for the CENTUM VP FIO system with ISA G3 and -20 to 70 °C environmental capability. It converts field voltage signals into channel data for the control system.

The non-isolated inputs of Yokogawa AAV141-S53/K4A00 measure each source against its differential return while sharing the module electrical arrangement. Keeping the source common-mode voltage within ±1 V prevents the field reference from moving outside the input circuit range.

Yokogawa AAV141-S53/K4A00 routes all sixteen inputs through the AEA4D terminal board, KS cable and ATK4A-00 adapter. The 10 ms update period controls how often converted data is refreshed, whereas the 100 ms step response describes how the displayed value settles after a voltage change.

02

Product Specifications

Brand Yokogawa
Model AAV141-S53/K4A00
Product Name G3 16-Channel 1-5 V Analog Input Module
Country Japan (manufacturer)
Input Channels 16, non-isolated differential
Input Signal 1 to 5 V DC
Environmental Option ISA G3 and -20 to 70 °C
Explosion Protection Not included
Common-Mode Limit ±1 V or less
Allowable Input Voltage ±7.5 V
Input Resistance 1 megohm or larger, power on
Accuracy ±4 mV
Data Update / Step Response 10 ms / 100 ms
Net Weight Approx. 0.20 kg
Interface Option ATK4A-00 KS cable interface adapter
03

G3 Voltage Input Deployment

AAV141-S53/K4A00 brings the G3 and extended-temperature option to a high-impedance voltage-input design that still depends on ordinary cabinet and wiring discipline.

Verify the full environmental code

Keep S53 visible in receiving, spares and installation records. AAV141-S50/K4A00 has the same signal function but not the same environmental suffix.

Confirm the cabinet, airflow and system-level requirements remain satisfied across the intended temperature range.

Stabilize before judging accuracy

Allow the cabinet and field source to reach a representative operating condition before comparing values.

Use a stable 1-5 V source so temperature effects in the transmitter or wiring are not assigned automatically to AAV141-S53/K4A00.

Protect the interface during maintenance

Keep KS connectors clean and latched and prevent cable strain from disturbing the adapter.

High-impedance voltage measurements can react to contamination or leakage that would be less visible in a current loop.

04

Differential Input Quality Control

The sixteen non-isolated differential channels of AAV141-S53/K4A00 need a deliberate reference, shield and verification method.

Measure common-mode voltage

Check each source relative to the module reference and keep the common-mode value within ±1 V.

If several channels shift together, test the shared reference before recalibrating individual measurements.

Use timing-aware tests

Hold each test value long enough to cover the 100 ms step response and any transmitter or controller filtering.

Do not use the 10 ms update figure as the only acceptance time for an end-to-end field change.

Trace the KS channel map

Inject known values into widely separated points and compare the AEA4D and controller numbering.

A consistent offset indicates mapping or connector alignment, while an isolated error points toward one field circuit.

05

Questions & Answers

01Why must AAV141-S53/K4A00 retain the S53 suffix?+

AAV141-S53/K4A00 includes ISA G3 and -20 to 70 °C capability; S50 has the same basic signal function but a different environmental selection.

02Why do multiple AAV141-S53/K4A00 values change together?+

AAV141-S53/K4A00 uses non-isolated differential inputs, so check the shared reference, shield bonding and common-mode voltage before changing channel calibration.

03Why does AAV141-S53/K4A00 appear slower than 10 ms?+

AAV141-S53/K4A00 updates data in 10 ms but has a 100 ms step response, and transmitter damping plus controller filtering can extend the observed end-to-end response.

04What can create leakage error on AAV141-S53/K4A00?+

For AAV141-S53/K4A00, inspect moisture, contamination, damaged insulation and high-resistance return paths because its voltage inputs are high impedance.

05How can a KS mapping problem be found on AAV141-S53/K4A00?+

Inject stable 1-5 V values into separated AAV141-S53/K4A00 channels and compare ATK4A-00, AEA4D and controller numbering for a consistent offset.

06What details should be sent for AAV141-S53/K4A00 supply?+

Provide AAV141-S53/K4A00, quantity, KS cable and AEA4D references, operating environment, nameplate photo, destination and requested inspection documents.

06

Brand Supply Scope

Moore Automation

https://www.mvme.cn

Moore Automation covers automation product families from Yokogawa, Emerson, Rockwell Automation, GE and Triconex. The scope includes control-system I/O, PLC hardware, turbine and drive components, safety-system modules and machinery-monitoring parts.

Process controlYokogawa CENTUM and Emerson DeltaV
PLC and turbineRockwell ControlLogix and GE Mark VIe
Safety systemsTriconex Tricon modules
07

Suggested Products

Siemens6ES7195-7HD00-0XA0
Siemens6EP3333-3SA00-0AY0
Vibro-Meter200-560-101-018
Siemens6ES7972-0BB70-0XA0
Siemens6ES7194-1AA01-0XA0
GEIS230JPDGH2A
Siemens3SE5112-0BE01
Siemens6ES7131-6BH00-0BA0
B&R8BVI0220HWD0.000-1
Siemens6GK5116-0BA00-2AC2
SiemensLMV27.210A2WH
TriconexTRICONEX 3664
Siemens6GT2002-0JE20
Siemens3VT8110-1AA03-0AA0
Vibro-Meter620-001-001-116
GEIS420PPDAH1B
Emerson1C31122G02/1C31125G2
Emerson5X00116G05
B&R8BVI0014HWD0.000-1
Emerson5X00062/5X00063
Emerson5X00790G0
TriconexTRICONEX 3626X
Emerson1C31224G01/1C31227G0
Emerson5X00063G01
Vibro-Meter200-530-022-014
Emerson5X00784G01G01
Emerson1C31181G01
GEIS200EBACH1A
EmersonKL2101X1
EmersonA6370D
Emerson5X00241G02
TriconexTRICONEX 3624
Siemens6ES5463-4UA12
Emerson5X00300G02/5X00321G01
Vibro-Meter200-565-000-013
Siemens6EP3332-3SA00-0AY0
Emerson1C31194G01/1C3119
GEDS200IIBDG1A
Siemens6ES7241-1CH31-0XB0
Emerson5X00790G01
B&R8BAC0120.000-1
Siemens6GK5408-0PA00-8AP2
EmersonKL2101X1-BB1
TriconexTRICONEX 3664E
Siemens6SL5568-0XX00-0AA0
B&R8V1640.00-2
Siemens6XV1875-5AH10
GEIS420YDOAS1B
TriconexTRICONEX 3625
Siemens6ES7222-1HF22-0XA8
B&R8BVI0028HWD0.000-1
Vibro-Meter200-530-025-014
Siemens6ES7953-8LG30-0AA0
TriconexTRICONEX 3636R
GEIS215ACLAH1A
Siemens6ES7123-1FB00-0AB0
Vibro-Meter200-570-000-111
B&R4PPC70.0573-20W
Siemens6ED1052-2FB00-0BA3
GEIS200ERSNG1A
Contact InformationMoore Automation
ManagerLeonia
WhatsApp+86 180 3017 5807

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.