Four-by-four current I/O
AAI835-S50/K4A00 combines four current inputs with four current outputs, supporting measurement and actuation within one isolated module.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa AAI835-S50/K4A00 / AAI135-S50/K4A00 Isolated Current I/O and Current Input Modules |
| Item NO. | 2932309 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-13 |
Yokogawa AAI835-S50/K4A00 provides four isolated 4 to 20 mA inputs and four isolated 4 to 20 mA outputs, while Yokogawa AAI135-S50/K4A00 provides eight isolated 4 to 20 mA inputs. Both modules support HART communication and belong to the isolated current-channel group.
In AAI835-S50/K4A00 and AAI135-S50/K4A00, S identifies the standard type, 5 identifies non-explosion construction and 0 identifies the basic environmental specification. The two models share a 10 ms update period and 0.3 kg approximate weight, but their channel direction and count are not interchangeable.
The /K4A00 option on AAI835-S50/K4A00 and AAI135-S50/K4A00 specifies the ATK4A-00 KS cable interface adapter. The same adapter family presents different signal maps: four inputs plus four outputs for AAI835 and eight inputs for AAI135.
| Specification | AAI835-S50/K4A00 | AAI135-S50/K4A00 |
|---|---|---|
| Brand | Yokogawa | Yokogawa |
| Product Name | 4-Input / 4-Output Isolated Current I/O Module | 8-Channel Isolated Current Input Module |
| Country | Not specified | Not specified |
| Input channels | 4 isolated channels | 8 isolated channels |
| Output channels | 4 isolated channels | None |
| Signal | 4 to 20 mA input and output | 4 to 20 mA input |
| Allowable input current | 25 mA | 25 mA |
| Output load resistance | 0 to 750 ohm | Not applicable |
| Circuit-open detection | Less than 0.65 mA on output | Not applicable |
| Accuracy | Input ±16 µA; output ±48 µA | Input ±16 µA |
| Data update period | 10 ms | 10 ms |
| HART communication | Available | Available |
| Isolation | Channel-to-system and channel-to-channel | Channel-to-system and channel-to-channel |
| Connection option | ATK4A-00 KS adapter | ATK4A-00 KS adapter |
| Approximate weight | 0.3 kg | 0.3 kg |
AAI835-S50/K4A00 / AAI135-S50/K4A00 share isolated current-input technology but serve different channel plans: mixed current I/O versus input-only acquisition.
AAI835-S50/K4A00 combines four current inputs with four current outputs, supporting measurement and actuation within one isolated module.
AAI135-S50/K4A00 allocates all eight channels to current input, increasing acquisition density without output circuits.
Both models can exchange HART information with supported field devices while the primary 4 to 20 mA values remain available to control blocks.
AAI835-S50/K4A00 / AAI135-S50/K4A00 can share adapter and node conventions, yet the project database must preserve the different channel direction and count.
Select AAI835 when four outputs are required; select AAI135 when all eight channels are inputs. Do not base the choice on faceplate similarity.
Both complete models specify /K4A00 and therefore the ATK4A-00 KS adapter, which must match the installed cable map.
Associate every HART identity with its actual input or output channel so the FIO node, adapter position and control-system point use the same signal direction.
For AAI835-S50/K4A00 / AAI135-S50/K4A00, verify the field device, channel assignment, HART-capable node environment, wiring quality and engineering database before replacing the module.
AAI835-S50/K4A00 / AAI135-S50/K4A00 both use /K4A00, but their channel functions differ. Use the model-specific terminal map rather than copying the same logical assignment.
On AAI835-S50/K4A00 / AAI135-S50/K4A00, first identify whether the point is an AAI835 output or an input channel; output open-circuit behavior and input signal loss require different loop checks.
The isolated channels in AAI835-S50/K4A00 / AAI135-S50/K4A00 can confine a field wiring, supply or device problem to one loop. Check that loop before assuming a node-wide defect.
If AAI835-S50/K4A00 / AAI135-S50/K4A00 was interchanged, confirm that an input-only AAI135 was not installed where an AAI835 output channel was engineered.
For AAI835-S50/K4A00 / AAI135-S50/K4A00, compare the module slot, ATK4A-00 terminal map, point direction and HART device list so the four-by-four and eight-input layouts remain distinct.
Moore Automation service support links each enquiry to its complete manufacturer and model record, requested quantity and accessory scope. Document questions and quotation details can therefore refer to the same item description.
After order confirmation, packing communication, dispatch information and tracking updates continue against that record so follow-up remains clear from enquiry to delivery.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found