Continuous current command
Sixteen channels convert control outputs into 4 to 20 mA field currents while maintaining isolation from the system side.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa AAI543-S60/A4S00 16-Channel Isolated Analog Output Module |
| Item NO. | 2932304 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-13 |
Yokogawa AAI543-S60/A4S00 is a 16-channel isolated 4 to 20 mA analog output module for field control applications. It provides channel-to-system isolation and supports dual-redundant operation where two identical modules occupy the required paired positions.
The S60 suffix of AAI543-S60/A4S00 identifies the standard communication type, the fast switch-over response version, non-explosion construction and basic environmental specification. During redundant transfer, the fast-response design limits the period in which a field output can fall below 4 mA to the documented short interval.
The /A4S00 option on AAI543-S60/A4S00 identifies the ATA4S-00 pressure-clamp terminal assembly. The terminal option, identical suffix in the standby module and supported node arrangement must remain aligned for the redundant output path to behave as engineered.
| Specification | AAI543-S60/A4S00 |
|---|---|
| Brand | Yokogawa |
| Product Name | 16-Channel Isolated Analog Output Module |
| Country | Not specified |
| Output channels | 16 isolated channels |
| Output signal | 4 to 20 mA DC |
| Allowable load resistance | 0 to 750 ohm |
| Circuit-open detection | Less than 0.65 mA |
| Accuracy | ±48 µA |
| Data update period | 10 ms |
| Redundant response | Fast switch-over version |
| Below-4 mA interval | Maximum 2 ms during supported redundant transfer |
| Withstanding voltage | 1500 V AC for 1 minute |
| Terminal option | ATA4S-00 pressure-clamp terminal |
| Explosion protection | Not included |
| Approximate weight | 0.4 kg |
AAI543-S60/A4S00 is defined by isolated 4 to 20 mA output performance and a fast redundant-transfer behavior intended for field devices sensitive to brief current interruption.
Sixteen channels convert control outputs into 4 to 20 mA field currents while maintaining isolation from the system side.
The output path detects a circuit-open condition below the documented threshold, helping engineering distinguish an external loop break from a normal low command.
The 6 suffix provides the fast switch-over response, limiting a supported redundant transfer below 4 mA to a maximum documented interval of 2 ms.
A fast redundant output only works when the two AAI543-S60/A4S00 records, slot positions, terminal assembly and receiving field loops are treated as one engineered arrangement.
Use identical AAI543-S60/A4S00 modules in the supported odd/even adjacent positions; mixing a standard-response suffix with the fast-response suffix invalidates the intended transfer behavior.
The ATA4S-00 terminal option must match the cabinet design and channel wiring. Retain terminal identifiers during module replacement or pair testing.
Check that each receiving device and cable keep total loop resistance within the 0 to 750 ohm range under the actual supply and operating conditions.
With AAI543-S60/A4S00, confirm the actual loop current, field-device calibration, load resistance, mechanical travel and configured engineering range. A correct module current does not prove the final element is calibrated.
AAI543-S60/A4S00 requires identical suffixes, supported adjacent slots and the correct redundant configuration. A mixed S50/S60 pair or incorrect slot assignment should not be expected to meet the 2 ms behavior.
The complete AAI543-S60/A4S00 record specifies /A4S00 and therefore the ATA4S-00 pressure-clamp terminal. A different interface requires an engineering and wiring review, not a suffix omission.
For AAI543-S60/A4S00, inspect the pressure-clamp termination, cable continuity, loop supply arrangement and receiving device. The module detects very low output current, but the root cause is often outside the module.
When all AAI543-S60/A4S00 channels are limited, check the shared field supply arrangement, terminal assembly seating and total loop resistance before adjusting individual channel scaling.
For AAI543-S60/A4S00, coordinate the test with operations, use an approved simulation or isolated test loop, and verify command, measured current and failover behavior before reconnecting the live actuator.
Moore Automation coordinates packing and shipment information after the product lines and destination have been confirmed. Package count, protective materials and consignee details are recorded before dispatch.
Tracking references and shipment updates remain linked to the corresponding commercial record, making it easier to compare the packed scope with the requested quantities.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found